SAFETY INSTRUCTIONS AND WARNINGS 

 

Do not attempt to use this bathing system without first understanding this manual. 

To ensure safe operation, carefully read this entire manual, especially the section on "Safety Instructions and Warnings", 
before installing, operating, or servicing this equipment. 
 
If anything is not completely understood, please contact  Reval for more details. 
Failure to comply with warnings in this manual may result in injury. 
Keep this manual with the tub and refer to it as required. Contents of this manual are subjected to change without prior 
notice to users. 
 

 

The Cocoon bathing system must be installed by a contractor or a certified installation technician.  

 

 

DO NOT try to lift the tub. 

 

DO NOT place limbs or lay underneath the tub during lowering function. 

 

DO NOT operate the air whirlpool pump without water. 

 

DO NOT pull on the shower head too forcibly. 

 

DO NOT immerse the shower handset in water. 

 

DO NOT place any object underneath the tub. 

 

DO NOT adjust the water temperature over 43°C in the presence of patient. 

 

DO NOT use any electrical appliances near the tub. 

 

DO NOT use any electrical appliances (hair dryer or electric razor, …) while in the tub. 

 

DO NOT force controls or taps. 

 

DO NOT use or turn the disinfection shower on the patient.

 

 

ALWAYS perform a daily check before using the bathing system. 

 

Each client should be assessed for his or her ambulatory capability to ensure the clients safety when entering and  

      exiting the bathing system. (Ability to utilize handgrips, correct entry height, etc.) 

 

ALWAYS be prepared before transferring a patient into the tub. 

 

ALWAYS check the water temperature before the patient enters the tub or to use the cleaning shower. 

 

Clean bathtub after each use. 

 

Disinfect bathtub between each use. 

 

All valves should be closed after bathing is completed. 

 

When using disinfectant, wear rubber gloves and eye protection. In case of eye or skin contact, follow the

 

     procedures on the disinfectant container.

 

 

A weekly safety check should be performed to ensure all hoses, pipes, connections and securing devices 

     are in safe working order.  

 

Keep all tub components clean and dry. 

 
 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

7/20 

Содержание 7800.00

Страница 1: ...EN Instruction manual ELECTRIC Hi Lo Bathtub Cocoon 7800 00 7801 00 7802 00 7803 00...

Страница 2: ...OTHERAPY OPTION 13 AUDIO SPA OPTION 13 AUTOMATIC STOP FILLING 1 LEVEL FOR 7801 00 7803 00 14 AUTOMATIC STOP FILLING 1 LEVEL FOR POUR 7800 00 7802 00 14 AUTOMATIC STOP FILLING 2 LEVELS 15 DISINFECTION...

Страница 3: ...ters up down buttons chromotherapy button air whirlpool controls automatic stop filling buttons flow intensity valve for cleaning shower handset Aromatherapy Cleaning shower handset Plug control overf...

Страница 4: ...DIMENSIONS 3 20...

Страница 5: ...er OPTIONS REF 7800 10 Disinfection shower handset with trigger flow adjustment suction device of the disinfectant product with stop valve 2 litres tank secured door with lock with key REF 7800 20 12...

Страница 6: ...stop filling 1 level on modes 7801 00 7803 00 Compatible with chair and stretcher lifts 40mm draining plug with siphon PERFORMS Max patient weight 160kg Max weight water patient 320kg Weight of the Co...

Страница 7: ...water for a better effectiveness of the disinfectant product A compressor assures whirlpool in option That is injection of air under pressure with adjustable flow through 12 nozzles equipped with anti...

Страница 8: ...b DO NOT adjust the water temperature over 43 C in the presence of patient DO NOT use any electrical appliances near the tub DO NOT use any electrical appliances hair dryer or electric razor while in...

Страница 9: ...GH LOW FUNCTIONS In order to change the height of the tub use the buttons located on the control panel PLUG OPERATION Turn the button in a clockwise direction to close the drain plug and counter clock...

Страница 10: ...ning shower after 30 seconds Check water temperature before each submersion If the bathtub is equipped with the option automatic stop of filling it is advised to carry out a test of the sensor before...

Страница 11: ...by the valve located under the mixer Filling and stop filling is made by turning the valve button CLEANING SHOWER HANDSET Select a temperature by adjusting the thermostatic It is possible to regulate...

Страница 12: ...do not forget to turn off the 1 4 turn stopcock a shower under pressure being much more fragile AIR WHIRLPOOL OPTION That is injection of air under pressure with adjustable flow through 12 nozzles equ...

Страница 13: ...matherapy system on via the circular control panel Once up to temperature the heated air infuses with the aroma oil and releases its fragrance into the water via the diffuser jets positioned in the bo...

Страница 14: ...s of two loudspeakers a waterproof amplifier a MP3 player and a control panel including the commands One Off and volume as well as an embedded box with removable panel allowing to receive and to conne...

Страница 15: ...automatically The sensor issues a magnetic field that is modified when water reaches it CONTROL PROCESS OF THE CAPACITIVE SENSORS 1 Start filling the bath 2 With the cleaning shower spray the inside...

Страница 16: ...tton n 2 To activate the water level n 2 push on the button n 2 and deactivate the button n 1 In case none of the buttons is activated the automatic stop filling does not work and the bathtub will fil...

Страница 17: ...e tub Do not use the disinfection shower on the patient Wait in order to respect the action time prescribed in accordance with the disinfectant used Rinse with the cleaning shower The bathtub is now r...

Страница 18: ...nce per week A regular cleaning of these 2 filters is imperative in order to reduce the limestone deposits in the pipes of the bathtub A bad maintenance of these filters generates times of long fillin...

Страница 19: ...oning of a whirlpool s nozzle Air is lown through the nozzle and discharged under the chromed air jet cap There is a risk of heating the air jet cap is the nozzles are not regularly cleaned Layers of...

Страница 20: ...h should be retained by the person s responsible for the servicing maintenance of the bathtub The date when corrective actions are taken in response to noted observations should also be noted in the l...

Страница 21: ...MAINTENANCE FORM LOGBOOK Agent name and signature Corrections Observations Safety parts Control date 20 20...

Страница 22: ...ulle Tel 33 05 46 42 04 16 Fax 33 05 46 43 06 38 www groupe reval com UNITED KINGDOM Reval Continuing Care Limited Unit 17 Brynmenyn Busines Centre St Theodore s Way Brynmenyn CF32 9TZ BRIDGEND WALES...

Отзывы: