background image

 

TECHNICAL SPECIFICATIONS

 

 
 

DESCRIPTION 

 

 

Reinforced fiberglass tub, white colour. 

 

Stainless steel handgrips.  

 

Variable height by electric jack and gas jack. 

 

Anti-vandal IP67 LED control buttons in stainless steel. 

 

Cleaning shower handset with flow adjustable valve. 

 

Grohe manual waste and overflow line. 

 

Models 7800.00 & 7802.00 : 54 l/min Watts Eurotherm thermostatic mixer with built-in check valves and scald 
protection. 

 

Models 7801.00 & 7803.00 : 48 l/min Rada Sense bath & shower concealed digital mixing valve offering programmable 
max, min & default temperatures, automatic temperature on outlet selection, duty flush and thermal disinfection with 
data logging capabilities. 

 

Solar temperature displays. 

 

Automatic stop filling (1 level) on modes 7801.00 & 7803.00 

 

Compatible with chair and stretcher lifts. 

 

Ø 40mm draining plug with siphon. 

 

PERFORMS 

 

 

Max. patient weight : 160kg 

 

Max. weight (water + patient) : 320kg 

 

Weight of the Cocoon R’GO bathtub : 130kg 

 

Weight of the Cocoon Key Hole bathtub : 140kg 

 

Variable height from 75 to 110cm 

 

COCOON R’GO TECHNICAL DATAS 

 

 

Ergonomical tub with « no-slip » concept and extra-height of the legs. 

 

Water volume for 20cm of height of water: 101 litres 

 

Water volume for 29cm of height of water: 175 litres 

 

Max. water volume until the overflow line: 228 litres 

 

Draining time: 4 min 

 

COCOON KEY HOLE TECHNICAL DATAS 

 

 

Flat floor tub in key hole shape and bath shortener 

 

Water volume for 20cm of height of water: 161 litres 

 

Water volume for 29cm of height of water: 253 litres 

 

Draining time: 5 min30 

 

COMFORMITY 

 

 

C.E. Marking 

 

73/23/CEE (Low Power Directive). 

 

89/336/CEE (Electromagnetic compatibility directive). 

 
 
 

 

5/20 

Содержание 7800.00

Страница 1: ...EN Instruction manual ELECTRIC Hi Lo Bathtub Cocoon 7800 00 7801 00 7802 00 7803 00...

Страница 2: ...OTHERAPY OPTION 13 AUDIO SPA OPTION 13 AUTOMATIC STOP FILLING 1 LEVEL FOR 7801 00 7803 00 14 AUTOMATIC STOP FILLING 1 LEVEL FOR POUR 7800 00 7802 00 14 AUTOMATIC STOP FILLING 2 LEVELS 15 DISINFECTION...

Страница 3: ...ters up down buttons chromotherapy button air whirlpool controls automatic stop filling buttons flow intensity valve for cleaning shower handset Aromatherapy Cleaning shower handset Plug control overf...

Страница 4: ...DIMENSIONS 3 20...

Страница 5: ...er OPTIONS REF 7800 10 Disinfection shower handset with trigger flow adjustment suction device of the disinfectant product with stop valve 2 litres tank secured door with lock with key REF 7800 20 12...

Страница 6: ...stop filling 1 level on modes 7801 00 7803 00 Compatible with chair and stretcher lifts 40mm draining plug with siphon PERFORMS Max patient weight 160kg Max weight water patient 320kg Weight of the Co...

Страница 7: ...water for a better effectiveness of the disinfectant product A compressor assures whirlpool in option That is injection of air under pressure with adjustable flow through 12 nozzles equipped with anti...

Страница 8: ...b DO NOT adjust the water temperature over 43 C in the presence of patient DO NOT use any electrical appliances near the tub DO NOT use any electrical appliances hair dryer or electric razor while in...

Страница 9: ...GH LOW FUNCTIONS In order to change the height of the tub use the buttons located on the control panel PLUG OPERATION Turn the button in a clockwise direction to close the drain plug and counter clock...

Страница 10: ...ning shower after 30 seconds Check water temperature before each submersion If the bathtub is equipped with the option automatic stop of filling it is advised to carry out a test of the sensor before...

Страница 11: ...by the valve located under the mixer Filling and stop filling is made by turning the valve button CLEANING SHOWER HANDSET Select a temperature by adjusting the thermostatic It is possible to regulate...

Страница 12: ...do not forget to turn off the 1 4 turn stopcock a shower under pressure being much more fragile AIR WHIRLPOOL OPTION That is injection of air under pressure with adjustable flow through 12 nozzles equ...

Страница 13: ...matherapy system on via the circular control panel Once up to temperature the heated air infuses with the aroma oil and releases its fragrance into the water via the diffuser jets positioned in the bo...

Страница 14: ...s of two loudspeakers a waterproof amplifier a MP3 player and a control panel including the commands One Off and volume as well as an embedded box with removable panel allowing to receive and to conne...

Страница 15: ...automatically The sensor issues a magnetic field that is modified when water reaches it CONTROL PROCESS OF THE CAPACITIVE SENSORS 1 Start filling the bath 2 With the cleaning shower spray the inside...

Страница 16: ...tton n 2 To activate the water level n 2 push on the button n 2 and deactivate the button n 1 In case none of the buttons is activated the automatic stop filling does not work and the bathtub will fil...

Страница 17: ...e tub Do not use the disinfection shower on the patient Wait in order to respect the action time prescribed in accordance with the disinfectant used Rinse with the cleaning shower The bathtub is now r...

Страница 18: ...nce per week A regular cleaning of these 2 filters is imperative in order to reduce the limestone deposits in the pipes of the bathtub A bad maintenance of these filters generates times of long fillin...

Страница 19: ...oning of a whirlpool s nozzle Air is lown through the nozzle and discharged under the chromed air jet cap There is a risk of heating the air jet cap is the nozzles are not regularly cleaned Layers of...

Страница 20: ...h should be retained by the person s responsible for the servicing maintenance of the bathtub The date when corrective actions are taken in response to noted observations should also be noted in the l...

Страница 21: ...MAINTENANCE FORM LOGBOOK Agent name and signature Corrections Observations Safety parts Control date 20 20...

Страница 22: ...ulle Tel 33 05 46 42 04 16 Fax 33 05 46 43 06 38 www groupe reval com UNITED KINGDOM Reval Continuing Care Limited Unit 17 Brynmenyn Busines Centre St Theodore s Way Brynmenyn CF32 9TZ BRIDGEND WALES...

Отзывы: