iBreeze CPAP Systems User Manual

Note:

When you receive your device, if the filter cotton is not installed, you must install 

the filter cotton before using the device.
To install or replace the air filter, please follow the below steps:

12.4 Traveling with the Device

Install the water tank back on the device.

12.5 Device Maintenance

No regular maintenance is required. If you notice abnormal running of the device, 
abnormal sounds, device or power supply drops from the tabletop, or have mistakenly 
operated, liquid has entered the device and the cover has ruptured, disconnect the 
power and contact your supplier.

13 Maintenance

RESVENT CPAP therapy device is designed to have a useful service life of 10 years. If 
the therapy device is used as intended in accordance with the instructions for use, it 
does not require any maintenance within this period. If the therapy device is used 
beyond this period, we recommend having it checked by an authorized dealer. If the 
respiratory air humidifier is used as intended in accordance with these instructions for 
use, it does not require any maintenance. If you identify faulty parts during the function 
check, please contact your authorized dealer immediately.

Содержание iBreeze Series

Страница 1: ......

Страница 2: ...Contents...

Страница 3: ...irway pressure therapy for the treatment of Obstructive Sleep Apnea OSA in spontaneously breathing patients weighting over 30kg 66lbs it is for use in the home hospital or institutional environment 3...

Страница 4: ...l face mask a mask covering both your mouth and your nose the mask must be equipped with a safety entrainment valve When using oxygen with this system always make sure that the device is turned on and...

Страница 5: ...nt the cord from being tripped over or interfered with by chairs or other furniture This device is activated when the power cord is connected For safe operation when using a humidifier the humidifier...

Страница 6: ...o either very hot or very cold temperatures allow it to adjust to room temperature operating temperature before starting therapy Do not operate the device outside of the operating temperature range sh...

Страница 7: ...re use Ensure that the therapeutic pressure settings were determined for the patient individually with the configuration of the equipment to be used including accessories For multiple patients use ple...

Страница 8: ...ng its conformity with the provisions of the Council Directive 93 42 EEC concerning medical devices and fulfils the essential requirements of Annex I of this directive European Authorized Representati...

Страница 9: ...his way up at transport and storage Fragile handle with care Keep dry at transport and storage Stacking limitations Recyclable materials 6 System Contents Your CPAP system may include the following it...

Страница 10: ...r lifts open for access to SD card 10 Air Inlet Port Inlet for room air 11 Filter Cotton Cover Open the filter cotton cover to place or change the filter cotton 7 1 Placing the Device Place the device...

Страница 11: ...at the power supply and at the electrical outlet are fully inserted 5 When turn off the device Press Therapy On Off Button and the device will stop work 6 Disconnecting Network power source WARNING D...

Страница 12: ...d and replace the tubing as necessary 3 Attach the headgear to the mask if necessary WARNING If you are using a full face mask a mask covering both your mouth and your nose the mask must be equipped w...

Страница 13: ...The fill line indicates 2 3 water level for safe operation The fill line indicates the maximum water level for safe operation CAUTION Use only room temperature distilled water or purified water Do not...

Страница 14: ...oot buzzer sh and then contact the supplier for inspection 2 Put on your mask assembly Refer to the instructions supplied with the mask 3 Press the key on top of the device to turn on airflow and begi...

Страница 15: ...h 3 months 6 months 1 year 5 Humidity Set humidifier level to enhance patient comfort of respiration Option Auto OFF 1 8 Default 3 Note 1 The humidity level only can be set when the water in humidifie...

Страница 16: ...ace Description 1 The current therapy mode 2 Display the alarm messages 3 Humidity adjustment shortcut key and humidity level Note The humidity level is available when the humidity function is on 4 Ba...

Страница 17: ...fier function is turned off Preheat function will be disable 3 Preheat function is not available in the iBreeze 20C P Ramp Set the starting pressure of Ramp Setting Range 3 cmH2O Setting pressure 0 5...

Страница 18: ...Description Option On OFF Default ON IPR Set IPR Intelligence Pressure Release level Option OFF 1 3 Default 2 Tube Type Set the Tube type Option 15 mm 19 mm Default 15 mm Mask Type Set the Mask type O...

Страница 19: ...ese French Spanish Russian Polish Default English Note Not all the languages are available the optional items depend on software version Energy Saving Set the Energy Saving function on or off When Ene...

Страница 20: ...N GPRS optional Set the GPRS function on or off Option ON OFF Default OFF Reminder Set the Reminder type and time You can turn on or off the different type of reminders including Mask Filter Water tan...

Страница 21: ...hs 6 months 1 year Usage Number of hours the device has been used in the selected period AHI The average apnea hypopnea index in the selected period Mask fit Use three stars for rating the leakage of...

Страница 22: ...our supplier for purchasing 10 Device Alert There are 4 types of alerts described here Alert 0 Gray bottom white tips no light no sound always display disappear until the prompt condition not met Aler...

Страница 23: ...e SD card storage space only 200M Replace the SD card or clean the data after export the data in the SD card written please unlock and insert again Notification The SD card is read written Remove the...

Страница 24: ...etting service life replace the mask It is time for device maintenance Please contact the service provider for device maintenance Notification In standby state the usage time exceed the setting device...

Страница 25: ...ust therapy parameter setting Mask vent holes blocked Alert 1 Mask vent holes is blocked Check the mask Low Tidal Volume Vt Alert 0 During breath cycle Average Vt less than 0 6 Setting Value Check the...

Страница 26: ...home care provider Return both the device and power supply to your provider so they can determine if the problem is with the device or power supply Air is leaking from around my mask Mask may be fitt...

Страница 27: ...dropped or mishandled Unplug the device Reapply power to the device If the problem continues contact your home care provider My water tank is leaking Water tank may not be assembled correctly Water ta...

Страница 28: ...reparation performed before using the device again Send the device to the authorized dealer 12 1 Cleaning the Device WARNING To avoid electrical shock always unplug the power cord from the wall outlet...

Страница 29: ...rated liquid has entered the device and the cover has ruptured disconnect the power and contact your supplier 13 Maintenance RESVENT CPAP therapy device is designed to have a useful service life of 10...

Страница 30: ...ssories in a dry place 14 2 Disposal Electronic waste Do not dispose of the product in the household waste Consult an authorized certified electronic waste recycling company for proper disposal You ca...

Страница 31: ...lectrical equipment Part 2 70 Particular requirements for basic safety and essential performance of Sleep apnea breathing therapy equipment ISO 8185 2009 Respiratory tract humidifiers for medical use...

Страница 32: ...e cmH2O 4 8 12 16 20 19mm breathing tubing Measured pressure at the patient connection port cmH2O 2 9 7 1 11 0 15 1 19 1 Average flow at the patient connection port L min 154 3 146 4 135 7 125 3 114 1...

Страница 33: ...ccuracy 70 100 2 Pulse Rate Range 18 250 bpm Pulse Rate Accuracy 18 250 bpm 3 bpm Note refer the user manual version 1 1 for more details Model iPOM iPOM Lite SpO2 Range 70 100 SpO2 Accuracy 80 100 2...

Страница 34: ...ransmitters and the CPAP system as recommended in form A 3 according to the maximum output power of the communications equipment Form A 1 Guidance and Declaration Electromagnetic Emissions Emissions t...

Страница 35: ...kV line s to line s 1 kV line s to earth 2 kV Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on power supply...

Страница 36: ...240MHz 5500MHz 5785MHz 9V m rms 10V m 80 Am at 1kHz 27V m PM at 18Hz 28V m FM 5 kHz deviation at 1kHz sine 9V m PM at 217 Hz 28V m PM at 18Hz 28V m PM at 217 Hz 28V m PM at 217 Hz 9V m PM at 217 Hz 80...

Страница 37: ...obile RF Communications Equipment and the CPAP system Rated maximum output power of transmitter W Separation distance in meters m according to frequency of the transmitter 150kHz 80MHz 80MHz 800MHz 80...

Страница 38: ...rors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this manual Contents of this manual are subject to change without prior notice...

Страница 39: ...Room 602 Building B C Gaoxinqi Industrial Park Liuxian No 1 Road Xingdong Community Bao an 518100 Shenzhen PEOPLE S REPUBLIC OF CHINA Tel 0086 755 23027370 Fax 0086 755 23027370 http www resvent com...

Страница 40: ......

Отзывы: