USER MANUAL DOOROPENER
12
RESQTEC Manual DOOROPENER (DM087K01)
Generally speaking it is most important is to keep your equipment clean. Clean equipment will not wear down as fast;
hence a longer service life can be achieved.
WEAR PERSONAL PROTECTION EQUIPMENT DURING MAINTENANCE. ENSURE THAT THE USED HYDRAULIC OIL IS
COLLECTED AND DISPOSED OF IN A RESPONSIBLE MANNER.
6. MAINTENANCE & STORAGE
6.1. MAINTENANCE AFTER USE
ACTION
EXPLANATION
ADDITIONAL INFORMATION
1.
Check the product and hoses for any
damage.
• Visually check for damage.
• Check the unit for excessive oil leakage.
• Check the spreading jaws and foot for
excessive wear.
If structural damage to the product
is discovered, contact your Resqtec
distributor/supplier.
2.
Clean and dry the product before storage.
• Preferably use dry, clean paper cloth.
• Mild soapy water can be used if
necessary.
Do NOT use any oil.
Dry thoroughly after using water.
3.
Clean and dry the hoses used before
storage.
• Preferably use dry, clean paper cloth.
• Mild soapy water can be used if
necessary.
Do NOT use any oil.
Dry thoroughly after using water.
4.
Check the couplers and dust caps for dirt.
Clean if necessary.
• Use dry, paper cloth.
Do NOT use any oil.
5.
Check coupler functioning after cleaning.
Place the dust caps when finished.
• Connect and disconnect the coupler at
least 3 times.
If the coupler is not functioning
properly, contact your Resqtec
distributor/supplier.