Limitations of Use
Failure to follow all instructions on the use of this product may adversely affect the
wearer’s health, may lead to severe illness or permanent disability or even death.
Only for use by trained competent personnel.
The PRPS(T) suit should not be used in areas immediately dangerous to life or health
(IDLH), or in atmospheres containing less than 19.5% oxygen.
The
PRPS(T)
does
not
provide
any
protection
against
either
liquid
or
gaseous
chemical
contamination
but
does
provide
respiratory
protection
to
the
level
of
EN12941:1998
TH3,
nominal
protection
factor=500.
If the suit is mechanically damaged in any way it
MUST NOT
be used and
MUST
be
disposed of.
It is likely that the wearer's body temperature will rise whilst wearing the suit and care
should be taken to guard against excessive loss of body fluid. Use of the optional
re-hydration facility is recommended.
Leave the work area immediately and remove the suit if:
a) Any part of the system becomes damaged e.g. tears or punctures in the suit.
b)Airflow into the suit decreases or stops, or visor misting occurs.
c) Breathing becomes difficult.
d)Dizziness or other distress occurs.
e) You taste or smell contaminants or an irritation occurs.
f) An alarm condition occurs.
Never modify or alter this product.
The usable temperature range of the ensemble is -5°C to +40°C <90% humidity.
If the wearer notices any discolouration of the visor the suit
MUST NOT
be used.
NEVER
change any component parts associated with the suit in a contaminated
area.
Materials used in the construction of the system are not known to cause allergic
reactions to the majority of individuals. The system contains no components made
from natural rubber latex.
This equipment is not to be used in oxygen-deficient environments, e.g. confined
spaces. For further information refer to the instructions for the 3M Jupiter™ AFU.
For any enquiries please contact the Respirex customer services department on
Tel : +44(0) 1737 778600 or Fax : +44(0) 1737 779441.
3
The PRPS(T) does not provide protection against heat or flame, it should therefore
not be worn in potentially flammable or explosive
atmosphere
s.