background image

• 

Materials that may come into contact with the wearer’s skin are not known to cause allergic reactions to 

the majority of individuals (please see glove user instructions). These products contain no components 

made from natural rubber latex.

• 

Continuous contact with certain chemicals can adversely effect the field of vision and protection offered 

by the visor. If the end-user notices any discolouration of the visor the suit should be withdrawn from use.

• 

The GLS 300 A suit DOES NOT provide protection against heat or flame, it should therefore not be worn 

in potentially flammable or unassessed explosive environments. It is not to be used in the handling of 

explosives.

• 

To achieve proper electrostatic dissipative performance, the person wearing the suit shall be properly 

earthed. The resistance between the person and the earth shall be less than 10

8

Ω,  e.g.  by  wearing 

adequate footwear.

• 

Electrostatic dissipative clothing should not be worn in oxygen enriched atmospheres without prior 

approval by a responsible safety engineer.

• 

The  electrostatic  dissipative  performance  of  the  suit  can  be  affected  by  wear  and  tear  and  possible 

contamination.

• 

When selecting boots it is recommended that consideration be given to their compatibility with the 

electrostatic properties of the suit.

• 

Barrier Laminate material does not breathe. The wearer’s body temperature will rise whilst wearing the 

suit and care should be taken not to lose too much body fluid. The wearer should leave the work area 

and remove the suit before becoming distressed.

For any enquiries please contact the Respirex customer services department on 
Tel : +44 (0)1737 778600 or Fax : +44 (0)1737 779441.

Email: http://www.respirexinternational.com/en/about-us/contact-us/

Storage

The GLS 300 A suits should be stored under the following conditions:
In dry conditions above ground level; away from direct sunlight and in an environment free from harmful gases 

and vapours.
Temperature range of -5°C* to +30°C, < 90% humidity. 
*Care should be taken when storing the suits at extreme temperatures. At sub-zero temperatures the flexibility 

of the material may be reduced, resulting in a potential lowering of the protection offered.
Only remove the single-use GLS 300 A suit from its original packaging when intending to use.
DO NOT fold or crease the visor, this will help to keep its natural shape.

Pre-checks

1.  Visually inspect the suit for any damage that may impair the correct working of the garment together with 

the gloves.

2.  The zip operates correctly and the slider is in good condition.
3.  The suit materials are free from tears and holes. Pay particular attention to the seam areas.
4.  Check vision through the visor is not impaired by scratches or heavy scuff marks.

2

Содержание GLS 300 A

Страница 1: ...1 1 2012 Method 2 Test Liquid jet tight to EN14605 2005 A1 2009 High level liquid spray tight to EN14605 2005 A1 2009 Low level liquid spray tight to EN13034 2005 A1 2009 Particle tight to EN13982 1 2004 A1 2010 GLS 300 A Chemical Protective Suit User Instructions ...

Страница 2: ...Dressing Procedure 3 Decontamination for removal of suit 6 Undressing Procedure 6 Cleaning Maintenance Accessories 6 Disposal 6 Product labelling 7 Chemical Permeation Testing At Respirex 8 Material Performance Data 8 Whole Suit Performance 9 Sizing 10 Glove User Instructions 12 ...

Страница 3: ...374 1 2003 EN388 2003 EN420 2003 permanently attached to the suit for data specific to the use of KCL Butoject gloves please refer to the user information supplied Two exhalation valves are fitted to the rear of the suit which automatically releases any excess pressure which builds up inside the garment during use The suit MUST be worn in combination with self contained open circuit compressed air...

Страница 4: ...atic properties of the suit Barrier Laminate material does not breathe The wearer s body temperature will rise whilst wearing the suit and care should be taken not to lose too much body fluid The wearer should leave the work area and remove the suit before becoming distressed For any enquiries please contact the Respirex customer services department on Tel 44 0 1737 778600 or Fax 44 0 1737 779441 ...

Страница 5: ...OLLOW THIS PROCEDURE MAY RESULT IN THE ZIP SPLITTING 2 Remove all personal affects which may result in damage to the suit e g watches badges jewellery etc 3 Remove shoes or boots The integral bootees are not designed to accommodate footwear 4 Tuck trousers into socks to make donning of suit legs and bootees easier 5 While seated carefully place each leg in turn into the suit then fold the outer le...

Страница 6: ... and Fig 6 8 With the wearer now standing pull the crotch of the suit up to the waist then clip the belt securely around the waist see Fig 7 9 With the assistance of the dressing assistant the wearer should now don the breathing apparatus set SCBA in accordance with manufacturer s instructions At this stage the SCBA should not be started and the face mask should be left hanging on its strap around...

Страница 7: ...CL Butoject gloves it is recommended that cotton gloves are worn inside the Butyl gloves attached to the suit whilst the dressing assistant lifts the suit up and over the head and breathing apparatus set see Fig 12 and Fig 13 12 The dressing assistant should fasten the zipper carefully following the reverse of the procedure outlined in Step 1 keeping the zip straight with one hand as you pull the ...

Страница 8: ...g the reverse of the procedure outlined in the dressing instructions keeping the outer surface of the suit away from the wearer at all times 3 As the dressing assistant pulls the suit forward the wearer s arms should be withdrawn from the sleeves and safety gloves this step may turn the sleeves of the suit inside out 4 The dressing assistant should fold the suit down to the top of the boots so tha...

Страница 9: ... s Model number 3 Manufacturer s Style No 4 Manufacturer s Order No 5 Customer Name 6 Garment Size info respirex co uk www respirexinternational com LB123 EN14605 2005 A1 2009 Issue B SUPROS MODEL Nr GLS 300 A STYLE STYLE No GLS300A132V66S31L27Z60 WORKS ORDER Nr RESPIREX GMBH CUSTOMER NAME SAMPLE DATE OF MANUFACTURE April 2017 TEL 44 0 1737 778600 FAX 44 0 1737 779441 112 124 182 194 SIZE DO NOT R...

Страница 10: ...441 or Email laboratory respirex co uk where our qualified staff will be happy to help you Outside of normal working hours 9 00am 5 00pm Mon Fri please leave details of your enquiry on the answer phone service so that the laboratory staff can deal with your query with the minimum of delay Material Performance Data Unless otherwise stated all data shown indicates performance characteristics of the ...

Страница 11: ...istance 30o C 2 of 6 EN ISO 9073 4 Trapezoidal tear resistance 4 of 6 EN ISO 13934 1 Tensile strength 3 of 6 EN 863 Puncture resistance 2 of 6 EN 13274 4 Method 3 Resistance to ignition Pass EN class specified by EN 14325 2004 the higher the class number the better the performance Whole Suit Performance Tests carried out under laboratory conditions by independent accredited laboratories Performanc...

Страница 12: ...ge of height chest sizes suitable for the GLS 300 A suit check your body measurements to make sure you are suitable Body measurements in cm Size Height Chest S 163 175 88 96 M 169 182 96 104 L 176 188 104 112 XL 182 194 112 124 XXL 188 200 124 136 10 ...

Страница 13: ... 0158 Dinnendahlstrasse 9 44809 Bochum Germany Notified Body No 0158 Article 11B Type Examination By BSI Product Services Kitemark Court Davy Avenue Knowhill Milton Keynes MK5 8PP UK Notified Body No 0086 RESPIREX INTERNATIONAL LTD Unit F Kingsfield Business Centre Philanthropic Road Redhill Surrey RH1 4DP United Kingdom Tel 44 0 1737 778600 Fax 44 0 1737 779441 www respirexinternational com ...

Страница 14: ...Glove User Instructions ...