background image

E

N

G

L

IS

H

RespirAide Tech Inc.

13-100 Hanlan Road
Woodbridge, Ontario Canada 
L4L 4V8
Tel:  1-866-874-2532
Fax: 1-905-850-5553

www.respiraide.com

**RespirAide is a trademark of RespirAide Tech Inc.

R

Before operating the system, please read 
this manual thoroughly, and retain it for 
future reference.
This unit cannot be used in atmosphere 
containing explosive dust, gas or oxygen,or 
in an area where flammable dust is present. 

If so, it may result in explosion or fire!

This product can be used only where the 
power supply is 120V/60Hz. You cannot 
use the unit if the power voltage is different.

WARNING

Model No. 

RespirAide 300T

Operation Manual

ERI JU

07655-7001

ISO 9001:2000

TUV

US

Pr

od

uc

tio

m

on

ito

re

d

S

af

et

te

st

ed

PRODUCT SERVICE

NRTL

Phase

ELECTRONIC AIR PURIFIER

Manual

Auto

Sensor

Check alarm

Safety switch

Filter & UV lamp
replacement alarm

Timer

  Button melody

   Remote control

Содержание 300T

Страница 1: ...t gas or oxygen or in an area where flammable dust is present If so it may result in explosion or fire This product can be used only where the power supply is 120V 60Hz You cannot use the unit if the power voltage is different WARNING Model No RespirAide 300T Operation Manual ERI JU07655 7001 ISO 9001 2000 TUV US C P r o d u c ti o n m o n it o r e d S a f e t y t e s t e d PRODUCT SERVICE NRTL Ph...

Страница 2: ...Numbers and Names BEFORE OPERATION Remote Control Setup OPERATION Display Indicator Lights Main Unit Operation Remote Control Operation CARE AND MAINTENANCE Main Unit Cleaning the Pre filter Cleaning the Electronic Cell Replacing the Activated Carbon Filter Photo catalytic Filter and UV Lamp TROUBLESHOOTING WIRING DIAGRAM SERVICE REMINDER SCHEDULE E 4 E 5 E 6 E 15 17 E 14 E 7 E 8 11 E 8 E 14 E 8 E...

Страница 3: ...l number Serial number Date of purchase Dealer name Address City Province Postal code Telephone Phone 1 866 874 2532 Write For service problems guarantee information missing items and other assistance RepirAide Tech Inc 13 100 Hanlan Road Woodbridge Ontario Canada L4L 4V8 Please provide the following information when you write or call model number serial number date of purchase your complete maili...

Страница 4: ...rial or workmanship within one 1 year of the date of purchase This limited warranty does not cover the replacement of expendable or consumable parts such as filters and other parts subject to normal wear unless they are defective in material or workmanship This warranty shall not apply if A Any defects caused or repairs required because of abusive operation negligence accident improper installatio...

Страница 5: ... become electrically charged as they pass through the powerful electric field The collector plates immediately attract and collect these charged dust and dirt particles 3 The Activated Carbon Filter absorbs and reduces odors chemicals and gases removes tobacco smoke the smell of food and other odors 4 The UV sterilization chamber kills bacteria and viral microorganisms such as influenza TB and Leg...

Страница 6: ...nel is removed while the unit is running Easy Maintenance and Low Cost When the electrostatic precipitator Electronic cell needs to be washed or the filters need to be replaced simply open the front panel and pull out the electronic cell or old filters and put the new or clean one in No screws hooks or tools are required The electronic cell captures small particles on aluminum plates that are simp...

Страница 7: ...ied person Do not insert fingers or foreign objects into the intake or air outlet The batteries must be removed from the remote control before disposal and the batteries must be disposed of safely Keep hair loose clothing fingers and all parts of body always from openings and moving parts Do not use the unit in an enclosed space where oxygen flammable explosive or toxic vapors are given off by oil...

Страница 8: ...sed in atmosphere containing explosive dust gas or in an area where flammable substances are present If so it results in explosion or fire DO NOT cleanse the unit or any parts e g pre filter electronic cell or activated carbon filter etc with alcohol gasoline paint thinner or other flammable substances It may cause fire Acohol After cleaning the pre filter it is very important to dry it completely...

Страница 9: ...toward to the cell If not it may cause fire See page E 19 20 Be careful not to tip over the unit when opening the front panel or moving it If not It may cause personal injury After cleaning the filters make sure to dry the cell thoroughly before reinstalling If not it can cause breakdown of the unit or personal injury DO NOT wash or reuse the activated carbon filter or clean the activated carbon f...

Страница 10: ...hock or damage the equipment If any parts of the power source gets wet remove the plug and dry it completely before reusing Use the product in the ambient temperature of 0 40 C 5 C 40 C Relative humidity 75 Use a fuse with proper capacity Never use a wire in place of a fuse Doing this may lead to malfunction or fire Copper Wire Do not place the product in direct contact with sunlight It may cause ...

Страница 11: ...5X1 Operation Manual 101348 101347 211904 202906 202915 211101 211103 211317 101345 101346 101370 211106 202914 211801 211502 211109 211111 211112 101324 101529 101201 211201 211115 202203 202501 211110 211501 211312 211301 202204 202807 202507 101325 202109 101351 202508 211102 ...

Страница 12: ...rcuit Board 211103 Circuit Board Protector 101346 Power supply transfomer 101351 Power Supply 101370 Interlock Switch 101325 UV Lamp Holder 202109 UV Light Blocker 211502 Power Contact Plate 202915 Activated Carbon Filter Complete 202906 Electronic Cell Complete 202914 Pre filter Complete 202507 Ground Contact Plates 211106 Front Panel Unit Air Intake Grill 101529 Magnetic Catcher 211801 Unit Epox...

Страница 13: ...ange is about 19 feet 6m 6 Make sure there are no objects blocking the path of the signal 7 Avoid dropping or damaging the remote control 8 Do not use it in high humidity conditions or in direct sunlight or near a heat source Battery Information 1 Open the cover on the rear of the remote control towards the arrow 2 Replace the battery with CR2025 battery Be sure to set the battery with the side up...

Страница 14: ...SPEED TIMER UV LAMP 2h AUTO ON Power ON Indicator Light When the power cord is inserted to the outlet the light will light up yellow and pressing the POWER button to start the unit it will turn to green Gas sensor air inlet Remote receiver Receive signals from remote control UV LAMP Indicator Light When the UV lamp works the light is on and if the indicator light flashes it tells the time for UV l...

Страница 15: ...ive ion generator light on the control panel will go out 4 UV LAMP Button When pressed turn off the UV lamp pressing again will turn on the UV light with the indicator light on 1 POWER Button Press the POWER ON OFF button to start operating the unit Pressing the button again will stop operation 3 TIMER Button Press the TIMER button to select the time for operation Each time it is pressed the timer...

Страница 16: ...when the POWER button is pressed Pressing the button again will stop operation AUTO Button At AUTO mode the fan speed is automatically switched H M L depending on the amount of pollution in the air Transmitter UV LAMP Button When pressed turn off the UV lamp SPEED Button The fan speed can be switched among Low Medium and High settings TIMER Button The set time switches every time the button is pre...

Страница 17: ...ft brush or a neutral cleaner to clean then dry completely before placing it back into the unit 5 Place the pre filter back into the front panel by sliding straight down into the slots WARNING 1 DO NOT clean the pre filter with flammable substances alcohol gasoline paint thinner etc It may cause fire 2 After cleaning the pre filter it is very important to dry it completely before placing it back i...

Страница 18: ...ted carbon filter in front of the cell It may cause fire C The WIRE SCREEN SIDE of the activated carbon filter should face the cell See below figures Replacing the Activated Carbon Filter When the FILTER LIFE indicator light on the control panel flashes yellow the activated carbon filter needs to be replaced 1 Stop the operation and unplug the unit 2 After waiting for 5 10 seconds open the front p...

Страница 19: ...mp After removing the UV light blocker gently rotate the lamp a quarter turn in either direction until it unlocks from the socket Pull the pins out the sides of the socket one end at a time After replacement of activated carbon filter or UV lamp be sure to press Filter Reset Button RESET1 Button or UV Lamp Reset Button RESET2 Button on the remote control for 5 times Once the Reset Buttons have bee...

Страница 20: ...oblems first and then unplug the power cord Call the Customer Service to ask for after sale service or make inquiries There is too much dust on the sensor There is too much dust on the electronic cell Automatic function does not work properly When other problems in terms of functions are found When functions do not work The system does not operate at all Power failure Power plug disconnected The F...

Страница 21: ...ector 2nd stage Ionizer 1st stage Black Red Red Red WIRING DIAGRAM Model 300T Remote control receiver Display Board Transformer Red Red Red Blue Black Yellow JZ12 JZ5 JZ5 JZ4 JZ9 JZ13 JZ3 JZ8 JZ7 JZ1 JZ2 JZ6 JZ11 JZ10 Black Red Main Circuit Board Y Green Pink white Gas sensor Pink white Pink white H M L C Power supply HVG Fuse Green Power cord socket Transfomer Blue Blue 18V F1 Reset button ...

Страница 22: ...E 23 SERVICE REMINDER SCHEDULE Pre filter Wash Reminder Year J F M A M J J A S O N D Electronic Cell Wash Reminder Year J F M A M J J A S O N D Memo Memo ...

Страница 23: ...ad Woodbridge Ontario Canada L4L 4V8 Tel 1 866 874 2532 Fax 1 905 850 5553 www respiraide com RespirAide reserves the right to revise or modify products and or specifications without notice The contents of this manual are subject to change without notice R ...