Ensure that all power is 
switched off before   
installing or maintaining 
this product 

 

ML Multistage Thermostat Installation Guide 

 

www.resourcedm.com 

 
 
485T Genus/Third Party Compatible 

 

The 

485t

 

option shows a value representing the network type. The possible values are: 

 

Value 

Network Type 

Genus compatible (all versions) 

Not Used in this version 

Not Used in this version 

 

 
Genus Compatible 

 

485A Genus 

The 

485A

 option shows a value representing either the name of the controller in a Genus compatible network. 

 
The value shown is of the form 

05-6

. This means the controller would try to log onto a Genus compatible network using 

the name ‘RC05-

6’. 
 
Once  the  address  has  been  entered,  use  the  net  menu  items  to  go  to  the  “Esc”  screen  and  press  enter.  This  registers  the  network 
address into the controller and the controller will log on at this point. 
 

Gadd 

 

The 

gAdd

 option displays (in hexadecimal format) the underlying network address assigned to the controller when it is logged onto the 

network. 

 

RLog 

 

The 

rLog

 

option allows the controller to be logged back onto the network with its current name. The ‘rLog’ message will flash for 

confirmation. Press the Enter button to execute the command, Up or Down buttons to cancel.  

 
ClrA 

 

The 

CLrA

 

option will clear out the network address and name in the controller. The ‘ClrA’ message will flash for confirmation. Press the 

Enter button to execute the command, Up or Down buttons to cancel. 
 
To enter this mode, hold the Enter, Up and Down buttons together for approximately 3 seconds until the message 

CLrA

 appears on the 

display.

 CLrA

 is the first option in the menu consisting of the following options: 

 

Display   Option 

CLrA 

Clear the address/name from the controller 

ESC 

Exit Setup mode 

 
Pressing the Enter button to select the 

CLrA

 

option will cause the ‘

CLrA

’ message to flash for confirmation, if the network type is set to 

Genus compatible. Press the Enter button to execute the command, Up or Down buttons to cancel. If the network type is not set to 
Genus compatible then the 

ClrA

 message will not flash and the ESC option can be used to exit the menu.  

 

 

SoFt  (Software version) 

 
Press “Enter” at this display to show the software version. 
 
 

OFSt 

 
Probe offsets: - select a channel (1 - 4) and select an /- 20

 O

C (68

 O

F) 

 
 

ESC 
 

Press enter at this display to quit out of the menu. 

 

 
 
 

 
 
 

Содержание PR0122-STA

Страница 1: ...ata Management Ltd 80 Johnstone Avenue Hillington Industrial Estate Glasgow Scotland G52 4NZ UK 44 0 141 810 2828 Switchboard support resourcedm com Technical Support sales resourcedm com Sales Enquiries For Products PR0710 PR0711 PR0720 PR0721 ML Thermostat PR0122 STA PR0123 STA ...

Страница 2: ...nts Introduction 3 Display 3 Relay Modules 4 Parameter Tables 6 Setting up 7 Viewing Changing Menu Items 7 Menu Items 7 Inputs and outputs 8 Units 8 Disp 8 Type 8 RTC 8 Hub Switch Type 8 Network Configuration 9 Network Compatibility 9 IP Communications 9 485 Networks 10 Operation 12 Network Alarms 12 View I O 13 Specification 13 General 13 Relays 14 Inputs 14 Part Numbers 14 REVISION HISTORY 14 ...

Страница 3: ...whole numbers Multi stage thermostat 4 stages heating or cooling per stage 2 x control probes with control weighting 2 x monitoring probes with optional alarms or 2 Plant fault inputs Programmable parameters Fan control relay with over run feature High volume Alarm buzzer Installation Can be switched off RS232 output for IP Network connection RS485 network version Genus compatible Local or remote ...

Страница 4: ...supply the switched mains outputs for the relays are fed by the relay module so only one mains supply needs to be connected 5 Relay module with RS232 connector for connection to an IP Network Connections NEUTRALS Supply Neutral connections LIVE Supply Live connections N C Relay normally closed contact N O Relay normally open contact All relays will output the supply voltage Note Earth is a functio...

Страница 5: ...contact N O Relay normally open contact Network Cable part number Belden 8723 or equivalent All relays will output the supply voltage Note Earth is a functional earth not a safety earth 170mm 70mm 75mm 75mm 70mm 133mm 149mm Fixing Centre Display Connection RS485 Comms Connector Temperature Probe Connector 1A Anti Surge Fuse Supply Neutral Supply Earth Supply Live Functional Earth Functional Earth ...

Страница 6: ...1 Cooling 2 Heating Heating Sets the thermostat stage function P 22 Stat 2 control weight 0 100 50 Weighting is biased to Probe 1 P 23 Stat 2 cut in 60 to 60 76 to 140 18 64 4 O C O F Heating relay is on below this set point Cooling relay is off below this set point P 24 Stat 2 diff 60 to 60 76 to 140 1 1 8 O C O F Heating relay goes off above this set point Cooling relay goes off below this set p...

Страница 7: ... Time P 69 Thursday Fans On Time 00 00 23 59 08 00 hrs mins Thursday On Time P 70 Thursday Fans Off Time 00 00 23 59 20 00 hrs mins Thursday Off Time P 71 Friday Fans On Time 00 00 23 59 08 00 hrs mins Friday On Time P 72 Friday Fans Off Time 00 00 23 59 20 00 hrs mins Friday Off Time P 73 Saturday Fans On Time 00 00 23 59 08 00 hrs mins Saturday On Time P 74 Saturday Fans Off Time 00 00 23 59 20 ...

Страница 8: ...contact Relay 2 Thermostat Stage 1 Use N O contact Relay 3 Thermostat Stage 2 Use N O contact Relay 4 Thermostat Stage 3 Use N O contact Relay 5 Thermostat Stage 4 Use N O contact ID Sets the controller ID normally used in conjunction with the IP L network mode Set a number in the range of 1 999 RTC Real time clock This will automatically synchronise on network systems a Use the up or down buttons...

Страница 9: ...d ML communication modules is shown below Note software version of the ML IP Module has to be V1 4 or higher Software versions older than V1 4 are not supported with the revised ML hardware platform The ML controller has to be set depending on the type of communication module in use See Hub Switch Type for further details Network Settings IP Communications There are 2 ways the ML controller can be...

Страница 10: ...network mask value in dotted IP format e g 255 255 255 0 then the table below gives the conversion Mask Length Mask Length Mask Length 255 255 254 0 23 255 254 0 0 15 255 255 255 252 30 255 255 252 0 22 255 252 0 0 14 255 255 255 248 29 255 255 248 0 21 255 248 0 0 13 255 255 255 240 28 255 255 240 0 20 255 240 0 0 12 255 255 255 224 27 255 255 224 0 19 255 224 0 0 11 255 255 255 192 26 255 255 19...

Страница 11: ...roller to be logged back onto the network with its current name The rLog message will flash for confirmation Press the Enter button to execute the command Up or Down buttons to cancel ClrA The CLrA option will clear out the network address and name in the controller The ClrA message will flash for confirmation Press the Enter button to execute the command Up or Down buttons to cancel To enter this...

Страница 12: ...rough a 7 day internal timer local or through a GP timer in a Data Manager Director front panel remote When the timer period goes off the thermostat function will stop but the fans can have a run on period P 04 which will keep the fans running until the run on period expires Network Alarms Alarm text Type index Over Temperature 4 Under Temperature 5 Log Over Temperature 8 Log Under Temperature 9 P...

Страница 13: ...70mm x 130mm x 50mm LxWxH Maximum Weight combined 1 25kg Safety Relay Board Class II LVD This product is double insulated when used with the original enclosure Safety Controller Class II LVD Only use the cable provided to connect the controller to the relay board EMC EN61326 1997 Amdt A1 1998 Ventilation No requirement for forced ventilation Insulation Class I for Relay board Class II for controll...

Страница 14: ...A Resistive Load N O contact 30 Vac 3A Inductive Load CosФ 0 4 Damage to relays through out of specification usage will invalidate the warranty Inputs Input 1 Thermistor probe Input 2 Thermistor probe Input 3 Thermistor probe or 0V return Input 4 Thermistor probe or 0V return Part Numbers ML Stat Controller 5 Relay RS485 Comms and Screw Terminals PR0122 STA ML Stat Controller 5 Relay RS485 Comms a...

Отзывы: