RE928X_Flexible Bus CDMA Communicator
Page
5
of
10
4-Feb-15
24-hour Tech Support: (715)808-0164
www.ResolutionProducts.com
Reporting Codes for DSC panels:
The following table shows all events reported when connected to a DSC Panel.
Event
Report Code
AC Fail/Restore
301
Panel Low Battery/Low Battery Restore
302
Opening/Closing Report
400
Cancel Report
406
Zone Alarm
See below
Automatic Contact ID is not supported. Manually programmed reporting codes
are only supported for alarms on zones 1-64 ([320] – [324]) and for alarms on
the PGM2/Aux input ([329]:[4]). The PGM2/Aux input is reported as zone
number 99.
If Report Codes have not been manually programmed for zone alarms, zone
alarm reporting codes default to:
•
Any zone alarm (zones 1-64): Code 1130 (Burglary)
•
PGM2/Aux input (zone 99, likely a 2-wire Smoke): Code 1110 (Fire)
Be sure to verify that all codes are being properly reported to the central
station after you have installed the communicator module or modified any
reporting program settings in the DSC installer programming menu.
Caddx NX Programming:
Compatible with all NX series panels
1. Refer to server setup instructions and setup account on the Dealer Portal.
2. Disarm the system (all partitions).
3. Power down the NX system.
4. Set the RE928X panel selector switch to CDX: DSC CDX HW UTC
5. Connect the NX panel and the RE928X as shown in the Wiring Instructions
above.
6. Apply power to the NX system. During this process, the communicator will
program the following settings:
Enable Opening and Closing reports
Set Telephone Line Cut delay to 0 (no TLM)
7. Installation complete.
Important:
Do not attempt to enter program mode until the CS and Platform
LEDs have stopped flashing.
Additional Notes for NX installations:
1. Some NX panels limit the number of non-keypad devices they support. Be
sure that the panel you are connecting the communicator to does not have
more than the number of support devices connected.
2. User codes that are added to the system or edited thru the communicator
will have the default or previous partitions enabled. If you desire the users
to have different partitions enabled, you will need to modify the partitions
thru the NX keypad.
RE928X_Flexible Bus CDMA Communicator
Page
6
of
10
4-Feb-15
24-hour Tech Support: (715)808-0164
www.ResolutionProducts.com
TroubleShooting the Panel Connection:
If the “CS or “Platform” LEDs are blinking, here are possible
problems:
Incorrect wiring
Incorrect panel switch position
Unsupported panel version
Unsupported panel model
AUI not enabled
AUI used for some other function
LRR not enabled
Another LRR or IP/GSM device connected to panel bus
Panel is in Installer Program Mode
Factory Default Button
This button has two functions:
a)
Holding this button for approximately 5 seconds will reset the RE928X
Communicator.
b)
Holding this button for approximately 10 seconds (LEDs will flash off
twice) will set the RE928X to factory defaults.
Operation
Event Reporting:
Events are reported to both the monitoring receiver and the interactive
server. All events use Contact ID reporting codes. The following events
are reported by default:
Alarms
System Low Battery
Alarm cancels
System Low Battery Restoral
Openings
AC Power Fail (delayed by some panels)
Closings
AC Power Restoral (delayed by some panels)
Vista Only:
Additional events can be enabled for reporting if desired, by enabling
the desired event reports in system programming.
Interactive Control:
The system may be controlled remotely through the interactive platform.
The arm/disarm control and status applies to partition 1 only.
Z-Wave
Z-Wave devices can be controlled via the Interactive function.
Siren (Future capability)
Resolution Wireless Siren will be useable to indicate alarm and statuses.