RE928X_Flexible Bus CDMA Communicator

 Page 

5

 of 

10

 

4-Feb-15 

24-hour Tech Support: (715)808-0164 

www.ResolutionProducts.com

 

 

Reporting Codes for DSC panels: 
 

The following table shows all events reported when connected to a DSC Panel. 

Event 

Report Code 

AC Fail/Restore 

301 

Panel Low Battery/Low Battery Restore 

302 

Opening/Closing Report 

400 

Cancel Report 

406 

Zone Alarm 

See below 

 
 
Automatic Contact ID is not supported. Manually programmed reporting codes 
are only supported for alarms on zones 1-64 ([320] – [324]) and for alarms on 
the PGM2/Aux input ([329]:[4]). The PGM2/Aux input is reported as zone 
number 99. 
 
If Report Codes have not been manually programmed for zone alarms, zone 
alarm reporting codes default to: 

 

Any zone alarm (zones 1-64): Code 1130 (Burglary) 

 

PGM2/Aux input (zone 99, likely a 2-wire Smoke): Code 1110 (Fire) 

 

Be sure to verify that all codes are being properly reported to the central 
station after you have installed the communicator module or modified any 
reporting program settings in the DSC installer programming menu. 

 

Caddx NX Programming: 

Compatible with all NX series panels 
 

1. Refer to server setup instructions and setup account on the Dealer Portal. 
2. Disarm the system (all partitions). 
3. Power down the NX system. 
4. Set the RE928X panel selector switch to CDX: DSC  CDX  HW  UTC 
5. Connect the NX panel and the RE928X as shown in the Wiring Instructions 
above. 
6. Apply power to the NX system. During this process, the communicator will 
program the following settings: 

   

 

Enable Opening and Closing reports 

   

 

Set Telephone Line Cut delay to 0 (no TLM) 

7. Installation complete. 

Important: 

Do not attempt to enter program mode until the CS and Platform 

LEDs have stopped flashing. 

 

Additional Notes for NX installations: 

1. Some NX panels limit the number of non-keypad devices they support. Be 
sure that the panel you are connecting the communicator to does not have 
more than the number of support devices connected. 
2. User codes that are added to the system or edited thru the communicator 
will have the default or previous partitions enabled. If you desire the users 
to have different partitions enabled, you will need to modify the partitions 
thru the NX keypad. 

 
 
 
 

RE928X_Flexible Bus CDMA Communicator

 Page 

6

 of 

10

 

4-Feb-15 

24-hour Tech Support: (715)808-0164 

www.ResolutionProducts.com

 

 

TroubleShooting the Panel Connection:

 

 
If the “CS or “Platform” LEDs are blinking, here are possible 
problems:

 

Incorrect wiring 
Incorrect panel switch position 
Unsupported panel version 
Unsupported panel model 
AUI not enabled 
AUI used for some other function 
LRR not enabled 
Another LRR or IP/GSM device connected to panel bus 
Panel is in Installer Program Mode 
 

Factory Default Button 

This button has two functions: 

a)

 

Holding this button for approximately 5 seconds will reset the RE928X 
Communicator. 

b)

 

Holding this button for approximately 10 seconds (LEDs will flash off 
twice) will set the RE928X to factory defaults. 

 
 
 

Operation 

 

Event Reporting:

 

Events are reported to both the monitoring receiver and the interactive 
server. All events use Contact ID reporting codes. The following events 
are reported by default: 

Alarms 

 

 

System Low Battery 

Alarm cancels 

 

System Low Battery Restoral 

Openings 

 

 

AC Power Fail (delayed by some panels) 

Closings 

 

 

AC Power Restoral (delayed by some panels) 

 

 

Vista Only: 

 

Additional events can be enabled for reporting if desired, by enabling 

 

the desired event reports in system programming. 

Interactive Control:

 

The system may be controlled remotely through the interactive platform.  

The arm/disarm control and status applies to partition 1 only.

 

Z-Wave

 

Z-Wave devices can be controlled via the Interactive function.

 

Siren (Future capability)

 

Resolution Wireless Siren will be useable to indicate alarm and statuses. 

 

 

 

 

 

 

Содержание RE928X

Страница 1: ...optimize cellular signal strength Mount as high in the building as possible RE927X communicates with the Vista 15P 20P via AUI device 2 Enable AUI 2 in the Vista The RE928X may be used as a backup for the RE920X or RE926X communicators Refer to Using RE928X as a Backup Wiring Instructions NOTE Some programming must be done PRIOR to connection Maximum cable lengths shown in the table below this ass...

Страница 2: ...ady to Arm 9 Installation is complete RE928X_Flexible Bus CDMA Communicator Page 4 of 10 4 Feb 15 24 hour Tech Support 715 808 0164 www ResolutionProducts com DSC Power Series Programming Compatible DSC Panels PC580 Power 432 PC5020 Power 864 PC1555 Power 632 PC1616 PC1555MX Power 632 PC1832 PC5010 Power 832 PC1864 PC5015 Power 832 1 Refer to server setup instructions and set up the account on the...

Страница 3: ... keypad devices they support Be sure that the panel you are connecting the communicator to does not have more than the number of support devices connected 2 User codes that are added to the system or edited thru the communicator will have the default or previous partitions enabled If you desire the users to have different partitions enabled you will need to modify the partitions thru the NX keypad...

Страница 4: ...Dealer Portal User Guide for details Power LED The rate the Power LED flashes indicates current operating mode Flashing every 1 second Primary Mode Flashing every 3 seconds Backup Mode RE928X_Flexible Bus CDMA Communicator Page 8 of 10 4 Feb 15 24 hour Tech Support 715 808 0164 www ResolutionProducts com LEDs Bus Board LEDs Indication Green On when the board is powered and running Red May flicker ...

Страница 5: ...vice and persons during operation To ensure compliance operation at closer than this distance is not recommended The antenna s used for this transmitter must not be co located or operating in conjunction with any other antenna or transmitter RE928X_Flexible Bus CDMA CommunicatorPage 10 of 10 4 Feb 15 24 hour Tech Support 715 808 0164 www ResolutionProducts com IC Notice This device complies with I...

Отзывы: