RE928X_Flexible Bus CDMA Communicator
Page
3
of
10
4-Feb-15
24-hour Tech Support: (715)808-0164
www.ResolutionProducts.com
Vista 20P and Vista 15P Programming
:
Compatible Honeywell Panels:
Vista 20P
(version 3.0 or later) (controls partition 1 only)
Vista 15P
(version 3.0 or later)
1)
Refer to server setup instructions and set up the account on the Dealer Portal.
2)
Disarm the system (all partitions).
3)
The RE928X automatically communicates with the Vista using AUI device 2.
The panel is probably defaulted to this. If not, enable AUI 2 in the *189 field.
4)
Power down the Vista system.
5)
Set RE928X panel selector switch to Honeywell: DSC CDX HW UTC
6)
Connect the Vista and RE928X as shown in the Wiring Instructions above.
7)
Apply power to the Vista 15P/20P system. It will automatically program.
a)
Be sure ALL partitions are disarmed.
b)
First, the Vista control panel will be busy for 50-60 seconds after powerup.
c)
Then, the module will enable the following settings automatically:
IP/GSM device (*29)
Communicate to IP/GSM device first (*55)
Test Report off (*64)
Opening Report (*65)
Closing reports (*66)
Alarm cancel report (*68)
AC Power restoral report (*73)
Low Battery restoral report (*74)
Phone Monitor off (*92)
8)
Finally, the keypad(s) should display "DISARMED Ready to Arm".
9)
Installation is complete.
RE928X_Flexible Bus CDMA Communicator
Page
4
of
10
4-Feb-15
24-hour Tech Support: (715)808-0164
www.ResolutionProducts.com
DSC Power Series Programming:
Compatible DSC Panels:
PC580 (Power 432)
PC5020 (Power 864)
PC1555 (Power 632)
PC1616
PC1555MX (Power 632)
PC1832
PC5010 (Power 832)
PC1864
PC5015 (Power 832)
1)
Refer to server setup instructions and set up the account on the Dealer
Portal.
2)
Using the system’s Installer Code:
a)
Disable the Communicator ([380]:[1])
b)
Disable the Telephone Line Monitor ([015]:[7])
c)
Delete Telephone Numbers (programming section 301-303)
3)
Verify Alarm report codes are setup properly for zones that are being used,
1-64 (programming section 320-349). System will report as Burg(130) if
programmed as FF.
4)
If using Aux input (PGM2) verify Aux input report codes are setup properly
(programming section 329:4). System will report as Fire (110) if
programmed as FF.
5)
All other reports are hardcoded in the gateway and cannot be changed
regardless of what is entered in the programmed location.
6)
Format and account number have no effect on reporting.
7)
Disarm the system (all partitions)
8)
Power down the DSC system.
9)
Set RE928X panel selector switch to DSC: DSC CDX HW UTC
10)
Connect the DSC Panel and RE928X as shown in the Wiring Instructions
above.
11)
Apply power to the DSC system.
12)
The DSC control panel will begin automatic configuration. This can take up
to 2 minutes.
13)
Installation complete.