RE928X_Flexible Bus CDMA Communicator

 Page 

3

 of 

10

 

4-Feb-15 

24-hour Tech Support: (715)808-0164 

www.ResolutionProducts.com

 

 

Vista 20P and Vista 15P Programming

Compatible Honeywell Panels: 

Vista 20P 

(version 3.0 or later) (controls partition 1 only) 

Vista 15P 

(version 3.0 or later) 

1)

 

Refer to server setup instructions and set up the account on the Dealer Portal. 

2)

 

Disarm the system (all partitions). 

3)

 

The RE928X automatically communicates with the Vista using AUI device 2.  

 

The panel is probably defaulted to this.  If not, enable AUI 2 in the *189 field.   

4)

 

Power down the Vista system. 

5)

 

Set RE928X panel selector switch to Honeywell:   DSC   CDX   HW    UTC 

6)

 

Connect the Vista and RE928X as shown in the Wiring Instructions above. 

7)

 

Apply power to the Vista 15P/20P system.  It will automatically program. 

a)

 

Be sure ALL partitions are disarmed. 

b)

 

First, the Vista control panel will be busy for 50-60 seconds after powerup.  

c)

 

Then, the module will enable the following settings automatically: 

IP/GSM device (*29) 

Communicate to IP/GSM device first (*55) 

Test Report off (*64) 

Opening Report (*65) 

Closing reports (*66) 

Alarm cancel report (*68) 

AC Power restoral report (*73) 

Low Battery restoral report (*74) 

Phone Monitor off (*92) 

8)

 

Finally, the keypad(s) should display "DISARMED Ready to Arm". 

9)

 

 Installation is complete. 

RE928X_Flexible Bus CDMA Communicator

 Page 

4

 of 

10

 

4-Feb-15 

24-hour Tech Support: (715)808-0164 

www.ResolutionProducts.com

 

 

DSC Power Series Programming:

 

 
Compatible DSC Panels: 

PC580 (Power 432)   

 

PC5020 (Power 864) 

PC1555 (Power 632)  

 

PC1616 

PC1555MX (Power 632) 

 

PC1832 

PC5010 (Power 832)  

 

PC1864 

PC5015 (Power 832)  

1)

 

Refer to server setup instructions and set up the account on the Dealer 
Portal. 

2)

 

Using the system’s Installer Code: 

a)

 

Disable the Communicator ([380]:[1]) 

b)

 

Disable the Telephone Line Monitor ([015]:[7]) 

c)

 

Delete Telephone Numbers (programming section 301-303) 

3)

 

Verify Alarm report codes are setup properly for zones that are being used, 
1-64 (programming section 320-349). System will report as Burg(130) if 
programmed as FF. 

4)

 

If using Aux input (PGM2) verify Aux input report codes are setup properly 
(programming section 329:4). System will report as Fire (110) if 
programmed as FF.  

5)

 

All other reports are hardcoded in the gateway and cannot be changed 
regardless of what is entered in the programmed location. 

6)

 

Format and account number have no effect on reporting. 

7)

 

Disarm the system (all partitions) 

8)

 

Power down the DSC system. 

9)

 

Set RE928X panel selector switch to DSC:  DSC   CDX   HW   UTC 

10)

 

Connect the DSC Panel and RE928X as shown in the Wiring Instructions 
above. 

11)

 

Apply power to the DSC system.  

12)

 

The DSC control panel will begin automatic configuration. This can take up 
to 2 minutes. 

13)

 

 Installation complete.

 

 
 
 
 
 
 
 
 
 
 
 

Содержание RE928X

Страница 1: ...optimize cellular signal strength Mount as high in the building as possible RE927X communicates with the Vista 15P 20P via AUI device 2 Enable AUI 2 in the Vista The RE928X may be used as a backup for the RE920X or RE926X communicators Refer to Using RE928X as a Backup Wiring Instructions NOTE Some programming must be done PRIOR to connection Maximum cable lengths shown in the table below this ass...

Страница 2: ...ady to Arm 9 Installation is complete RE928X_Flexible Bus CDMA Communicator Page 4 of 10 4 Feb 15 24 hour Tech Support 715 808 0164 www ResolutionProducts com DSC Power Series Programming Compatible DSC Panels PC580 Power 432 PC5020 Power 864 PC1555 Power 632 PC1616 PC1555MX Power 632 PC1832 PC5010 Power 832 PC1864 PC5015 Power 832 1 Refer to server setup instructions and set up the account on the...

Страница 3: ... keypad devices they support Be sure that the panel you are connecting the communicator to does not have more than the number of support devices connected 2 User codes that are added to the system or edited thru the communicator will have the default or previous partitions enabled If you desire the users to have different partitions enabled you will need to modify the partitions thru the NX keypad...

Страница 4: ...Dealer Portal User Guide for details Power LED The rate the Power LED flashes indicates current operating mode Flashing every 1 second Primary Mode Flashing every 3 seconds Backup Mode RE928X_Flexible Bus CDMA Communicator Page 8 of 10 4 Feb 15 24 hour Tech Support 715 808 0164 www ResolutionProducts com LEDs Bus Board LEDs Indication Green On when the board is powered and running Red May flicker ...

Страница 5: ...vice and persons during operation To ensure compliance operation at closer than this distance is not recommended The antenna s used for this transmitter must not be co located or operating in conjunction with any other antenna or transmitter RE928X_Flexible Bus CDMA CommunicatorPage 10 of 10 4 Feb 15 24 hour Tech Support 715 808 0164 www ResolutionProducts com IC Notice This device complies with I...

Отзывы: