• Panel will learn the CO alarm
• Recommended group is 81
• Test that the CO alarm is
enrolled in the panel
• Put panel into test mode
• Press and hold TEST button until
sounder is done sounding beeps
• Panel will indicate a CO sensor
has tripped
5.
Test that the CO alarm is enrolled
in
the panel.
6.
Review
Section 5
for CO alarm
testing and maintenance.
• Test the functionality of the CO
alarm weekly.
7.
Review
Sections 6 and 7
for
information regarding what to
do when the alarm sounds and
information regarding how to
protect your family.
8.
Review how to have your alarm
serviced per
Section 8.
9.
For troubleshooting information,
refer to
Section 9.
1. Read This First
Congratulations on becoming the owner
of a carbon monoxide alarm. This will
help protect you and your household
from the dangerous effects of carbon
monoxide - the silent killer.
• Wait 15 seconds after connecting
the power before button testing. We
recommend you:
• Install a CO alarm in every room that
contains a fuel burning appliance,
particularly rooms where people spend
a lot of time, such as bedrooms,
kitchens, etc.
• In rooms with an appliance, install
(preferably) on the ceiling (300mm
from walls) and between 1.5m to 3m
horizontally away from the appliance.
In rooms remote from the appliance,
install at ‘head height’, where the light
indicators can be seen.
Honeywell Compatible Enrollment
•
Place panel in enrollment mode
• Zone type= Carbon Monoxide
• Input type= Supervised RF
Transmitter
• When asked for a serial number:
trip tamper twice
• To tamper, turn base counter-
clockwise. Wait for two seconds
and restore the base. Wait for
three seconds and repeat steps.
• Select Loop 1 for CO
• Put panel into test mode
• Press and hold TEST button until
sounder is done sounding beeps
• Panel will indicate a CO sensor
has tripped
2GIG Compatible Enrollment
• Place panel in enrollment mode
• Q1: Select RF sensor number
(01-48) zone number of your
choice
• Select RF sensor type [14] 24
hour carbon monoxide (see
control panel installation manual)
• Select RF sensor equip type [1]
• Select RF sensor equip code
[0860] CO1-345 CO detector
• Select RF sensor serial number
and press shift, press learn trip
sensor
• Select RF sensor age [1] New
• Select RF sensor Loop number
[1]
• Put panel into test mode
• Press and hold TEST button until
sounder is done sounding beeps
• Panel will indicate a CO sensor
has tripped
DSC Compatible Enrollment
•
Place panel in enrollment mode
• Press and hold TEST button until
sounder is done sounding beeps
2