background image

•  Panel will learn the CO alarm
•  Recommended group is 81
•  Test that the CO alarm is 

enrolled in the panel

•  Put panel into test mode
•  Press and hold TEST button until 

sounder is done sounding beeps

•  Panel will indicate a CO sensor 

has tripped

5. 

Test that the CO alarm is enrolled 

in  

the panel.

6. 

Review 

Section 5

 for CO alarm 

testing and maintenance.

• Test the functionality of the CO 

alarm   weekly.

7. 

Review 

Sections 6 and 7

 for 

information regarding what to 

do when the alarm sounds and 

information regarding how to 

protect your family.

8. 

Review how to have your alarm 

serviced per 

Section 8.

9. 

For troubleshooting information, 

refer to 

Section 9.

 

1. Read This First

Congratulations on becoming the owner 

of a carbon monoxide alarm. This will 

help protect you and your household 

from the dangerous effects of carbon 

monoxide - the silent killer. 

• Wait 15 seconds after connecting 

the power before button testing. We 

recommend you:

• Install a CO alarm in every room that 

contains a fuel burning appliance, 

particularly rooms where people spend 

a lot of time, such as bedrooms, 

kitchens, etc.

• In rooms with an appliance, install 

(preferably) on the ceiling (300mm 

from walls) and between 1.5m to 3m 

horizontally away from the appliance. 

In rooms remote from the appliance, 

install at ‘head height’, where the light 

indicators can be seen.

Honeywell Compatible Enrollment

•  

Place panel in enrollment mode

•  Zone type= Carbon Monoxide
•  Input type= Supervised RF 

Transmitter

•  When asked for a serial number: 

trip tamper twice

•  To tamper, turn base counter-

clockwise. Wait for two seconds 

and restore the base. Wait for 

three seconds and repeat steps.

•  Select Loop 1 for CO
•  Put panel into test mode
•  Press and hold TEST button until 

sounder is done sounding beeps

•  Panel will indicate a CO sensor 

has tripped

2GIG Compatible Enrollment

•  Place panel in enrollment mode
•  Q1: Select RF sensor number 

(01-48) zone number of your 

choice

•  Select RF sensor type [14] 24 

hour carbon monoxide (see 

control panel installation manual)

•  Select RF sensor equip type [1]
•  Select RF sensor equip code 

[0860] CO1-345 CO detector

•  Select RF sensor serial number 

and press shift, press learn trip 

sensor

•  Select RF sensor age [1] New
•  Select RF sensor Loop number 

[1]

•  Put panel into test mode
•  Press and hold TEST button until 

sounder is done sounding beeps

•  Panel will indicate a CO sensor 

has tripped 

DSC Compatible Enrollment

•  

Place panel in enrollment mode

• Press and hold TEST button until 

sounder is done sounding beeps

2

Содержание RE115

Страница 1: ...nd hold TEST button until sounder is done sounding beeps Panel will indicate a CO Test by sounding temporal 4 siren one time Interlogix Compatible Enrollment Place panel in enrollment mode Press and hold TEST button until sounder is done sounding beeps Panel will learn the CO alarm recommended group 34 Test that the CO alarm is enrolled in the panel Put panel into test mode Press and hold TEST but...

Страница 2: ...on the ceiling 300mm from walls and between 1 5m to 3m horizontally away from the appliance In rooms remote from the appliance install at head height where the light indicators can be seen Honeywell Compatible Enrollment Place panel in enrollment mode Zone type Carbon Monoxide Input type Supervised RF Transmitter When asked for a serial number trip tamper twice To tamper turn base counter clockwis...

Страница 3: ...e red alarm light immediately and then sounds a loud alarm if the CO persists Table B shows how the CO Alarm reacts to different levels of CO gas and exposure time At higher levels of CO the alarm turns on sooner The rate of flashing of the red light indicates the level of CO If your CO Alarm sounds follow the instructions in Section 6 NEVER IGNORE THE ALARM 3 2 3 Symptoms of CO Poisoning CO in PP...

Страница 4: ...t warns the homeowner that the unit has previously detected CO gas and been in alarm The memory feature has two operation modes memory indication for 24 hour period after alarm memory recall on demand 24 hour memory indicators After alarm the RED light will flash at different rates every 50 seconds depending on the level of CO detected see the CO Response Table Memory recall on demand To review th...

Страница 5: ... Outside of each separate dwelling unit sleeping area in the immediate vicinity of the bedroom 2 On every occupiable level of a dwelling unit including basements but excluding attics and crawl spaces 3 Other locations where required by applicable laws codes or standards The equipment should be installed using wiring methods in accordance with the National Fire Protection Association s Standard 72 ...

Страница 6: ...e is a partition in the room the CO Alarm should be located on the same side of the partition as the potential source In rooms with sloped ceilings the CO Alarm should be located at the high side of the room see figure 2 3 32 If locating the CO Alarm in a bedroom or in rooms remote from a fuel burning appliance see figure 3 Mount the CO Alarm relatively close to the breathing zone of the occupants...

Страница 7: ...t At levels 300ppm CO the unit cannot be silenced Monitoring The CO alarm will self check monitor itself and give a status update every 50 seconds if there are any problems The status of the Alarm can also be checked on demand by using the test button If the Alarms are indicating a fault pressing the test button will silence the beeps for a 24 hour period This is for your convenience and can only ...

Страница 8: ...t exposures to high or low temperatures or high humidity may reduce battery life Use only batteries specified in marking Use of a different battery may have a detrimental effect on alarm operation For environmentally sound disposal remove the Alarm from its mounting plate Quick Test with Carbon Monoxide The Carbon Monoxide Alarm checks for CO gas every 4 seconds and when exposed to the CO gas the ...

Страница 9: ...rk after you have carefully read all the instructions check that the unit has been installed correctly and ensured that it has good 1 Operate reset Silence button 2 Call your emergency services Fire Department or 911 3 Immediately move to fresh air outdoors or by an open door window Do a head count to check that all persons are accounted for DO NOT re enter the premises until the emergency service...

Страница 10: ...re not suitable as early warning Smoke Alarms Some fires produce Carbon Monoxide but the response characteristics of these CO Alarms are such that they would not give sufficient warning of fire Smoke Alarms must be fitted to give early warning of fire 7 The CO Alarm does not detect the presence of natural gas methane bottled gas propane butane or other combustible gases Fit combustion Gas Alarms t...

Страница 11: ...there is no source of hydrogen such as batteries being charged e g on boats or in Uninterruptable Power Supplies UPS 5 Ensure there is not excessive smoke or fumes from smoking devices 6 Ensure that there are no problems with the other RF interconnected Alarms and that all Alarms are housecoded correctly 7 Press the test hush button to silence the alarm If the unit continues to sound it is possibl...

Страница 12: ...ioélectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement IC 8310A RE115 8310A RE215 8310A RE315 WARRANTY Resolution Products Inc will replace non portable products that are defective in their first five 5 years and all defective portable products in their first two 2 years 47 0024 00 RevA 2018 02 01 Tech Support Line 877 260 5578 www ResolutionProducts com FCC NO...

Отзывы: