RE108  Hardwire-to-GE

®

 Wireless Translator™

 

 

Features

 

 

Converts hardwire zones into GE-compatible wireless signals. 

 

8 Hardwire loops with end-of-line resistor detection. 

 

Unique wireless ID for each zone, plus 1 for main device. 

 

Transmit diversity for long reliable range. 

 

PIR/Glassbreak powering (via external supply). 

 

3 year operation on batteries (monitoring contacts only). 

 

Complete supervision of zone tampers and low battery. 

 

Key Instructions

 

 

DO NOT MOUNT IN A METAL CAN. 

 

DO NOT PUT POWER ON HARDWIRE TERMINALS. 

 

Use with normally closed contacts in-line with 4.7 K-ohms resistors (mandatory). 

 

Not for use with life safety devices, such as Smoke or CO sensors. 

 

External supply requirements:   

 

Contacts-only installations may use wall plug power supply (see specifications) 

 

Installations with PIRs or Glassbreaks (powered devices) require battery-
backed external power supply (see diagram).   

 

Without backed-up power, PIRs or Glass Breaks could alarm when 
power is lost.   

 

Translator AA batteries drive contacts only, and do not drive 
powered devices. 

 

Ensure that external supply has sufficient current to supply all 
powered devices including Translator. 

 

4-wire powered devices only.  Not for use with 2-wire powered 
devices. 

 

If using old panel as the battery-backed 12V DC supply, verify supply 

and battery operation. DO NOT MOUNT TRANSLATOR IN OLD CAN… the wireless will not 
get out!

 

Installation

 

 

Hook up PIR and Glass Break power lines to external power supply. 

 

Alarm contact hook-up: 

 

Works only with normally-closed contacts (alarm = open). 

 

Remove any existing end-of-line resistors. 

 

Connect 4.7K end-of-line resistor (included) IN-LINE with contact.   

 

Resistor should NOT be across (between) terminals. 

 

Enrollment: 

 

Put Panel in Learn Sensor mode. 

 

When panel asks to “Trip Sensor”, short (tamper) each loop to enroll it.  You 
can use a piece of wire or needle nose pliers between the terminal screws. 

 

To enroll Translator itself, press tamper switch on Translator. 

 

Select Group based on how you want Translator tamper to report: 

 

Group 10 will report Translator tamper to central station on 
next supervisory.  Tamper will cause protest at arming. 

 

Group 36 will alarm and report Translator tamper to central 
station immediately. 

RE108_Hardwire_to_GE-Compat_Translator

 

Page 

2

 of 

24-Hour Tech Support Line: (715)808-0164

 

15-Oct-14

 

www.ResolutionProducts.com

 

 

Application Diagram 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 

Connection Diagram 

 
 
 
 

New Wireless 
System 

 

Existing Hardwire Sensors 

 

New GE 
Self-Contained System in 
living area 

 

Taking over old Hardwire panel,  

usually mounted in utility area 

GE Wireless

 

4.7K

Contact 

(Normally Closed)

Loop

x

PIR

To Enroll zone, 

short the two terminals with 

a wire.

This sends a wireless 

tamper signal.

Translator AA 

Batteries DO NOT 

power external 

devices

Altronix AL100UL

12VDC  Supply

With Lead-acid 

battery

Old Panel may be used, 

if operation fully verified

+12 VDC          GND

PIR

Power

Input

PIR Contact 

Output

(Normally 

Closed)

4.7K

Loop

y

Altronix TP1620
16.5VAC, 20VA 

Transformer 

with securing screw

Resolution

RE012 

12 VDC 

Power Supply

NON-Switched

Outlet

Use Battery-Backed 12VDC

if powering 

PIRs or Glass Breaks

Use Non-Battery-Backed

Supply ONLY if installation is 

all non-powered contacts

Power Supply polarity

DOES NOT matter!

End of Line

Resistor

May use GE 60-898-ITI supply here, 
if securing screw is desired

 