en
4
1
Overview
• Pre-configured basic system
• 4 relay outputs (incl. 1 extra-low voltage relay)
• 4 inputs for Pt1000 temperature sensors
• 5 operating modes, room thermostat and night correction
• Holiday mode, chimney sweeper function and screed drying function via microbuttons
• Data logging, storing, easy transfer of controller adjustments prepared and
firmware updates via SD card
• Weather-compensated control with room influence or demand-based room
control with 1 room temperature sensor
• Remote access with a room control unit
• Function for using a central outdoor sensor unit
Technical data
Inputs: 4 inputs for Pt1000 temperature sensors (1 of them can be converted to
room thermostat (switch)), 1 input for remote control (RTA) or operating mode
switch (BAS)
Outputs: 3 semiconductor relays, 1 potential-free extra-low voltage relay,
1 PWM output, 1 0-10 V output
PWM frequency: 512 Hz
PWM voltage: 10.8 V
Switching capacity:
1 (1) A 240 V~ (semiconductor relay)
1 (1) A 30 V
⎓
(potential-free relay)
Total switching capacity: 3 A 240 V~
Power supply: 100 … 240 V~ (50 … 60 Hz)
Supply connection: type Y attachment
Standby: 0.63W
Mode of operation: type 1.B.C.Y action
Rated impulse voltage: 2.5 kV
Data interface: VBus
®
, MicroSD card slot
Functions: weather-compensated heating circuit control, room thermostat, chim-
ney sweeper function, screed drying function, holiday mode
Housing: plastic, PC-ABS and PMMA
Mounting: wall mounting, also suitable for mounting into patch panels
Indication / Display: full graphic display, operating control LED (Lightwheel
®
)
Operation: 4 buttons and 1 adjustment dial (Lightwheel
®
)
Protection type: IP 20 / DIN EN 60529
Protection class: I
Ambient temperature: 0 … 40 °C
Degree of pollution: 2
Dimensions: 110 x 166 x 47 mm
110
166
130
47
Upper fastening
Lower fastening