background image

3

No. of 

Red 

Light 

Blinks

Fault 

Description

Steps to Fix 

To be Performed by 

Professional HVAC 

Technician Only

7

HVAC power 

not present.

•  Turn humidistat off. 

•  At thermostat, validate that 

the FAN setting turns the 

blower on. If not, check the 

circuit breaker. If circuit is 

tripped, reset or replace 

fuse.

•  If fault persists, unplug 

TrueSTEAM and remove 

cover.

•  Validate proper TrueSTEAM 

wiring to R and C terminals, 

using installation guide  

(69-2036).

•  Ensure proper connection 

quality of the wires.

•  Inspect R and C wires at the 

HVAC equipment board, 

ensuring no breaks and 

good connection if wire 

nuts are used.

•  Hook AC volt meter across R 

and C to validate 20-30VAC 

is present. To measure, it may 

be necessary to close furnace 

interlock switch.

•  Secure TrueSTEAM cover and 

plug unit in. Press the RESET 

button.

•  If fault persists, recheck 

wiring or replace unit.

Note:

 If using VisionPRO IAQ 

to control TrueSTEAM, it is 

not necessary to monitor 

HVAC power. DIP 4 may 

be turned on to disable 

monitor.

8–11 The backup 

weld monitor 

input is 

active when 

the backup 

heater relay 

is off.

•  Replace the TrueSTEAM 

unit.

12

Tempera-

ture of the 

electronic 

circuit board 

is too high.

•  Ensure ventilation holes 

in the cover are clear of 

obstruction, and that 1 foot 

of clearance is maintained 

around the cover’s 

ventilation holes.

•  Ensure the TrueSTEAM is 

installed in a location with 

conditioned air 32°F (0°C) 

to 104°F (40°C). 

•  Turn humidistat off and 

allow time for electronic 

board to cool. Unplugging 

unit and removing cover will 

facilitate this.

•  Turn humidistat on and 

press RESET button. 

•  Confirm humidity call starts 

(HUMIDIFYING light turns 

on).

•  Allow unit to run and check 

for steam leaks around tank 

and ventilation holes.

•  If steam is present, replace 

TrueSTEAM.

No. of 

Red 

Light 

Blinks

Fault 

Description

Steps to Fix 

To be Performed by 

Professional HVAC 

Technician Only

13

Tank failed 

to drain.

•  Water in tank may be hot 

(>140ºF [60ºC]) and can 

cause burns.

•  Press and hold the EMPTY 

button for 3 seconds.

•  If unit fails to drain, turn 

humidistat to OFF, or 

unplug the humidifier and 

wait for water in tank to 

cool. Ensure tank water is 

cool before proceeding.

•  Once cool, follow tank 

cleaning steps in the 

Professional Installation 

Guide (69-2036EFS).

•  Reassemble tank and press 

the RESET button.

•  If fault persists, replace the 

solenoid valve.

14

Heater 

failed to boil 

water.

•  Press and hold EMPTY 

button for 3 seconds, and 

follow tank cleaning steps in 

the Professional Installation 

Guide.

•  Reassemble tank and press 

the RESET button.

•  Initiate humidistat call.

•  If fault returns, replace the 

unit.

No. of 

Red 

Light 

Blinks

Fault 

Description

Steps to Fix 

To be Performed by 

Professional HVAC 

Technician Only

15

No Airflow. •  Unplug TrueSTEAM and 

remove cover 

•  Validate proper wiring to 

terminals R and C, using the 

diagrams in the installation 

guide (69-2036). 

•  Ensure proper connection 

quality of the wires. 

•  Inspect R and C wires at the 

HVAC equipment board, 

ensuring no breaks and 

good connection if wire 

nuts are used. 

•  Hook AC volt meter across 

airflow switch normally-

open (N.O.) terminal and R. 

•  Set thermostat FAN to off 

and reduce system setpoint. 

•  Validate 0 VAC reading on 

AC Volt Meter 

•  Set thermostat FAN to on. 

•  Once blower starts, validate 

20-30VAC reading on AC 

volt meter. 

•  If voltage is not present, 

check wiring and switch 

functionality. Differential 

pressure switch may require 

a new install location (away 

from duct bends, etc), or it 

may need to be replaced. 

•  If voltage is present, 

continue to troubleshoot 

to validate proper airflow 

monitoring. 

•  Keep AC volt meter across 

airflow switch N.O. terminal 

and R from HVAC unit. 

•  Turn humidistat off. 

•  Ensure DIP 4 and 5 are in 

off (down) position. 

•  Secure TrueSTEAM cover 

and plug in unit. Press the 

RESET button. 

•  Set thermostat FAN to off 

and reduce system set 

point. 

•  Set humidistat call and 

monitor device. (may take 

15-20 minutes) 

•  When sound of blower 

clears, validate within 2 

minutes that the AC volt 

meter reads 20-30VAC. 

•  If time for switch to change 

state takes longer than 2 

minutes, try a new install 

location for the switch, 

where state change is faster. 

Содержание Honeywell Home TrueSTEAM HM512

Страница 1: ...ter will drain from the tank and the CLEAN TANK light will blink as it drains 3 When the CLEAN TANK is on solid the tank is empty 4 Turn the water valve arm to the UNLOCK position Grip the solenoid toggle valve and slide it back to disengage 5 Hold bottom of the tank while pressing down the safety release button on the cover and slide the handle forward 6 The sediment screen is on the inside of th...

Страница 2: ...ss hold RESET button until the red Call Service light turns off If tank still fails to fill press and hold the EMPTY button for 3 seconds if unit fails to drain unplug unit and make sure water in tank is cool Follow tank cleaning instructions in the Professional Installation Guide Ensure you have a firm grip of the tank prior to releasing the tank especially if water is present Clear any excess de...

Страница 3: ...old the EMPTY button for 3 seconds If unit fails to drain turn humidistat to OFF or unplug the humidifier and wait for water in tank to cool Ensure tank water is cool before proceeding Once cool follow tank cleaning steps in the Professional Installation Guide 69 2036EFS Reassemble tank and press the RESET button If fault persists replace the solenoid valve 14 Heater failed to boil water Press and...

Страница 4: ...2 69 2144 05 M S Rev 04 20 Printed in United States www resideo com 2020 Resideo Technologies Inc All rights reserved The Honeywell Home trademark is used under license from Honeywell International Inc This product is manufactured by Resideo Technologies Inc and its affiliates 69 2144 05 ...

Отзывы: