User’s Information

Lighting instructions.

Your furnace does not use a continuously burning pilot 
fl ame. Therefore, manually lighting your furnace is not 
required. Your furnace is equipped with an automatic 
ignition system. It  uses a hot surface ignition device 
that automatically lights the burners each time the 
comfort control signals the furnace to start. 

WARNING

!

BURN HAZARD

DO NOT ATTEMPT TO MANUALLY LIGHT THE FUR-
NACE.  

FAILURE TO  FOLLOW THIS WARNING  COULD 

RESULT IN PROPERTY DAMAGE, PERSONAL INJURY 
OR DEATH.

CAUTION

!

If the furnace is shut down during the cold weather 
months, provisions must be taken to prevent freeze-up 
of all water pipes and water receptacles.

  1. Please read all safety information in this book be-

fore operating furnace.

  2. Set comfort control to lowest setting. Turn off all 

electric power to furnace.

  3. Remove the furnace front panel to gain access to 

the main gas valve.

  4. Turn external main gas shutoff valve or the tog-

gle switch located on the main gas valve inside 
the unit  to the “OFF” position (see illustration on 
this page). If an external main gas shutoff valve 
is used, turn to “OFF” position (see illustration 
on next page). Allow 5 minutes for any gas within 
the unit to escape. LP gas being heavier than air 
may require forced ventilation. 

If you smell gas 

STOP! Follow the “What To Do If You Smell 
Gas” instructions on the front cover of this 
book. If you don’t smell gas, go to next step.

To Start the Furnace

Your furnace will have a switch to turn the gas ON or OFF.

  5. Turn the external main gas shutoff valve and the 

toggle switch located on the main gas valve inside 
the unit to the “ON” position (see illustration on 
this page). 

  6.  Replace the furnace front access panel.
 7. Turn on main electrical supply and set comfort 

control to desired setting. Combustion blower will 
start and ignition device will start to heat up. After 
approximately 15 seconds main gas valve will open 
and burners will ignite.

  8. When the comfort control is satisfi ed, main burn-

ers will extinguish.

 9. If main burners fail to ignite turn off the main 

electrical supply power or lower the comfort con-
trol setting and wait 5 minutes. 

 10. Raise the comfort control setting and restore elec-

trical supply power. Repeat steps 6 through 8.

 11. If furnace still will not light, turn “OFF” all gas 

and electricity to unit and call servicer or gas sup-
plier.

For complete shutdown.

Turn the external main gas shutoff valve and the tog-
gle switch on the main gas valve inside the unit to the 
“OFF” position. Disconnect electrical supply to unit.
Whenever your house is to be vacant, arrange to have 
someone inspect your house for proper temperature. If 
your furnace should fail to operate, damage could re-
sult, such as frozen water pipes.

Flame Roll-out Device.

All models are equipped with a manual resetting roll-
out switch located near the burners. In case of fl ame 
roll-out, the switch trips automatically shutting off 
all fl ow of gas.  The switch must be manually reset by 
pressing the red reset button on the top of the switch.

Gas Valve  On / Off
Toggle Switch

On/Off Switch

Содержание Condensing Gas Furnaces

Страница 1: ...nce WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department DO NOT RELY ON SMELL ALONE TO DETECT LEAKS DUE TO VARIOUS FACTORS YOU MAY NOT BE ABLE TO SMELL FUEL ...

Страница 2: ...tear out and spraying may generate fiber concentrations requiring additional respiratory protection Use the appropriate NIOSH approved respirator in these situations FIRST AID MEASURES Eye Contact Flush eyes with water to remove dust If symptoms persist seek medical attention Skin Contact Wash affected areas gently with soap and warm water after handling WARNING SAFETY HAZARD IMPROPER INSTALLATION...

Страница 3: ...so air openings provided to the area in which the fur nace is installed and the space around the furnace shall not be blocked or obstructed Keep this in mind should you choose to remodel the area which contains your fur nace If additional insulation is added after the furnace is installed the area around the furnace must be in spected to ensure it is free and clear of insulation If this furnace is...

Страница 4: ...tart the Furnace Your furnace will have a switch to turn the gas ON or OFF 5 Turn the external main gas shutoff valve and the toggle switch located on the main gas valve inside the unit to the ON position see illustration on this page 6 Replace the furnace front access panel 7 Turn on main electrical supply and set comfort control to desired setting Combustion blower will start and ignition device...

Страница 5: ...any questions UPFLOW FURNACE Manual Main Gas Shut off Valve May Be Located on the Left or Right Side DOWNFLOW FURNACE Manual Main Gas Shutoff Valve May Be Located on the Right or Left Side AUTOMATIC GAS VALVE WITH SHUTOFF AUTOMATIC GAS VALVE WITH SHUTOFF MAIN MANUAL SHUTOFF VALVE HORIZONTAL FURNACE Manual Main Gas Shut off Valve May Be Located on the Top or Bottom Side ...

Страница 6: ...way into the filter rack Replace blower access door A bottom return air inlet as shown fea tures a 17 x 25 x 1 filter in the 17 1 2 wide furnace cabinets a 20 x 25 x 1 filter in the 21 wide models and a 24 x 25 x 1 filter in the 24 1 2 wide cabinet For vertical UPFLOW ONLY a left or right return air inlet as above left side shown requires trimming of the factory supplied filter to 17 x 25 x 1 for ...

Страница 7: ...e filter grille The filter grille could be in a hallway wall or in the ceiling Check with your deal er for the exact location of your filter and the method of changing the filters REQUIRED FILTERS BOTTOM CABINET WIDTH FILTER QUANTITY SIZE 17 1 2 1 17 X 25 X 1 21 1 20 X 25 X 1 24 1 2 1 24 X 25 X 1 REQUIRED FILTERS SIDE CABINET WIDTH FILTER QUANTITY SIZE 17 1 2 1 17 X 25 X 1 21 1 17 X 25 X 1 24 1 2 ...

Страница 8: ...cal power to the furnace and contact a qualified service agency Keep your furnace looking like new for years Clean the enamel finish of your furnace with ordi nary soap and water For stubborn grease spots use a household detergent Lacquer thinner or other syn thetic solvents may damage the finish Problem Possible Trouble Possible Remedy No Heating Blower does not operate 1 Thermostat set incorrect...

Страница 9: ...UP PLY FAIL TO SHUT OFF SHUT OFF THE MANUAL GAS VALVE TO THE FURNACE BEFORE SHUTTING OFF THE ELECTRICAL SUPPLY FAILURE TO FOLLOW THIS WARNING COULD RE SULT IN PROPERTY DAMAGE PERSONAL INJURY OR DEATH 1 GENERAL INSPECTION Examine the furnace installation for the following items a All flue product carrying areas external to the furnace i e chimney vent connector are clear and free of obstruction b T...

Страница 10: ...equired For best operation burners must be cleaned annually using brushes and vacuum clean er NOTE On LP propane units due to variations in BTU content and altitude servicing may be required at shorter intervals 5 HEAT EXCHANGER FLUE PIPE These items must be inspected for signs of corrosion and or de terioration at the beginning of each heating season by a qualified service technician and cleaned ...

Страница 11: ...uding secondary heat exchanger without charge F O B nearest Parts Distribution point or allow a credit in the amount of the then current wholesale price of an equivalent heat exchanger toward the purchase price of a comparable heating unit Any local transportation related service labor air filters and diagnosis calls are not included This limited warranty does not apply if the gas furnace was purch...

Страница 12: ... products covered under this warranty No liability shall attach to Warrantor until products have been paid for and then liability shall be limited solely to the purchase price of the equipment under warranty shown to be defective This limited warranty does not apply if the gas furnace was purchased direct i e from internet websites or auctions on an uninstalled basis Additionally this limited warr...

Отзывы: