background image

 

 

 
 

IMPORTANT SAFETY INSTRUCTIONS 

 
Thank you for selecting this uninterruptible power system (UPS). It 

provides you with better protection for connected equipment. 

 

Please read this manual

 

This manual provides safety, installation and operating instructions than will 

help you derive the fullest performance and service life that the UPS has to 

offer. 

 

Please save this manual

 

It includes important instructions for the safe use of this UPS and for 

obtaining factory service should the proper operation of the UPS come into 

question. 

 

Please save or recycle the packaging materials

 

The UPS`s shipping materials were designing with great care to provide 

protection from transportation related damage. There materials are 

invaluable if you ever have to return the UPS for service. Damage sustained 

during transit is not covered under the warranty.

 

Содержание RPT-1000A

Страница 1: ...Use With Computer Loads Only Intelligent Auto Shutdown Software Power Surge Noise Protection Internet Line Protection Cost Efficiency AVR Protection Compact Reliable Design U US SE ER R S S M MA AN N...

Страница 2: ...that the UPS has to offer Please save this manual It includes important instructions for the safe use of this UPS and for obtaining factory service should the proper operation of the UPS come into que...

Страница 3: ...rating of the UPS Below 1 2 or 1 3 of rated power is recommended for longer backup time longer battery life Do not place the UPS near excessive humidity under sunshine or close to heat emitting sourc...

Страница 4: ...Cut off No battery drain after cut off Physical Dimension D W H 385 94 170 mm Operating Temperature 32 104 at full load 0 90 relative humidity non condensing Environment Noise Level Less than 40db at...

Страница 5: ...9 Pin Female Connector Signal High Min 3 Second Contacts Normally Open Low Battery Mains Failure Pin Number UPS Shut Down 5 8 6 3 1 4 7 2 9 8 OVERVIEW Front Panel 1 Master Power Switch Turn on off the...

Страница 6: ...2 FEATURES 2 3 SYSTEM CONCEPT BLOCK DIAGRAM 3 NORMAL OPERATION 3 AC UTILITY FAILURE 4 4 OVERVIEW FRONT PANEL 5 REAL PANEL 5 PICTURE 5 5 INSTALLATION AND OPERATION 7 6 COMPUTER INTERFACE 8 7 BATTERY FA...

Страница 7: ...re auto shutdown 2 TROUBLE SHOOTING If the UPS failed to operate properly please review the following checks firstly If the problem remain please consult sales agent for service Is the Master power sw...

Страница 8: ...ing the unit Recharge batteries every 3 months is necessary if it is not in use because it may cause batteries over drain WARNING Only a qualified technician should replace the battery Batteries have...

Страница 9: ...hemical fumes Check the identification label to verify the UPS voltage and power rating match the available line voltage and load requirements Installation 1 Check if the main switch on the UPS front...

Страница 10: ......

Страница 11: ......

Отзывы: