Figure 14: Serial Port (RJ-45) Pin-Out
WIRING MAP FOR SERIAL CABLE
Table 4: Serial Cable Wiring
Switch’s 8-Pin Serial Port
Null Modem
PC’s 9-Pin DTE Port
2 RXD (receive data)
-----------------
3 TXD (transmit data)
3 RXD (receive data)
-----------------
2 RXD (receive data)
5 SGND (Signal ground)
-------------------
5 SGND (Signal ground)
N
OTE
:
No other pins are used.
Figure 15: Plug in the Console
Port
The serial port’s configuration requirements are as
follows:
◆
Default Baud rate—115,200 bps
◆
Character Size—8 Characters
◆
Parity—None
◆
Stop bit—One
◆
Data bits—8
◆
Flow control—none
2 TXD
5 GND
3 RXD
Publication date: Oct., 2012
Revision A3
17
Содержание GEPOESM-ESW26K Series
Страница 1: ...26 Port L2 PoE Plus Managed Switch Installation and Getting Started Guide ...
Страница 10: ...Back of the Switches GEPoESM ESW26 GEPoESM ESW26K Publication date Oct 2012 Revision A3 2 ...
Страница 16: ...Figure 6 Office Network Connection GEL2 ESW08 GEL2 ESW10 GELPoE2 ESW26 Publication date Oct 2012 Revision A3 8 ...