Страница 2: ... PoE Plus Managed Switch Installation and Getting Started Guide 2012 Manufacture Corporation All rights reserved All brand and product names are trademarks or registered trademarks of their respective companies Publication date Oct 2012 Revision A3 i ...

Страница 3: ...ventions are used throughout this guide to show information WARRANTY See the Customer Support Warranty booklet included with the product A copy of the specific warranty terms applicable to your Manufacture products and replacement parts can be obtained from your Manufacture Sales and Service Office pr authorized dealer NOTE Emphasizes important information or calls your attention to related featur...

Страница 4: ...ill be required to correct the interference at his own expense You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment You may use unshielded twisted pair UTP for RJ 45 connections Category 3 or better for 10 Mbps connections Category 5 or better for 100 Mbps connections Category 5 5e or 6 for...

Страница 5: ...ics Dry weather conditions or walking across a carpeted floor may cause you to acquire a static electrical charge To protect your device always Touch the metal chassis of your computer to ground the static electrical charge before you pick up the circuit device Pick up the device by holding it on the left and right edges only If you need using outdoor device connect to this device with cable then ...

Страница 6: ...k of electric shock Disconnect all AC or DC power cord and RPS cables to completely remove power from the unit Before importing exporting configuration please make sure the firmware version is always the same After firmware upgrade the switch will remove the configuration automatically to latest firmware version RELATED PUBLICATIONS The following publication gives specific information on how to op...

Страница 7: ...ST 10 PACKAGE CONTENTS 10 MOUNTING 10 INSTALLING AN OPTIONAL SFP TRANSCEIVER 13 CONNECTING TO A POWER SOURCE 16 CONNECTING TO THE CONSOLE PORT 16 Operation of Web based Management 18 MAKING NETWORK CONNECTIONS 20 CONNECTING NETWORK DEVICES 20 TWISTED PAIR DEVICES 20 FIBER OPTIC SFP DEVICES 22 CABLE LABELING AND CONNECTION RECORDS 25 TROUBLESHOOTING 26 Basic Troubleshooting Tips 26 POWER AND COOLIN...

Страница 8: ...OUGH WIRING 30 1000BASE T PIN ASSIGNMENTS 31 CABLE TESTING FOR EXISTING CATEGORY 5 CABLE 31 FIBER STANDARDS 32 SPECIFICATIONS 33 PHYSICAL CHARACTERISTICS 33 SWITCH FEATURES 34 MANAGEMENT FEATURES 34 STANDARDS 34 COMPLIANCES 35 COMPLIANCES 36 Publication date Oct 2012 Revision A3 vii ...

Страница 9: ...er connected workforce The GEPOESM ESW26K Series 26 Ports Switch is broad portfolio of easy implement managed Ethernet switches Models include with 26 port of Gigabit Ethernet connectivity providing ideal flexibility to design suitable network infrastructure for business requirement However unlike other entry level switching solutions that provide advance managed network capabilities only in the c...

Страница 10: ...Back of the Switches GEPoESM ESW26 GEPoESM ESW26K Publication date Oct 2012 Revision A3 2 ...

Страница 11: ...forwarded This prevents errors from being propagated throughout the network NETWORK MANAGEMENT OPTIONS The switch can also be managed over the network with a web browser or Telnet application The switch includes a built in network management agent that allows it to be managed in band using SNMP or RMON Groups 1 2 3 9 protocols It also has an RJ45 console port connector on the front panel for out o...

Страница 12: ...abled The following table shows a list of transceiver types which have been tested with the switch For an updated list of vendors supplying these transceivers contact your local dealer For information on the recommended standards for fiber optic cabling see 1000 Mbps Gigabit Ethernet Collision Domain on page 28 Table 1 Supported SFP Transceivers Media Standard Fiber Diameter microns Wavelength nm ...

Страница 13: ...ic is present TP SPEED Green Lit Green when TP link on 1000Mbps Blinks when TP link on 100Mbps Off when TP link on 10Mbps SFP Link ACT Green Amber Lit Green when SFP link on 1000Mbps speed Lit Amber when SFP link on 100Mbps speed Blinks when any traffic is present Table 3 System Status LED SYSTEM LED Condition Status Power Green OFF Lit when power is coming up POWER SUPPLY SOCKET There are a power...

Страница 14: ...count back to zero and removes the limitation A switch can be easily configured in any Ethernet Fast Ethernet or Gigabit Ethernet network to significantly increase bandwidth while using conventional cabling and network cards APPLICATION EXAMPLES The GEPOESM ESW26K Port Series Switch implements 24 Gigabit Ethernet TP ports with auto MDIX and 2 slots for the removable SFP module GEPOESM ESW26K port ...

Страница 15: ...gure 4 Network Connection between Remote Site and Central Site Figure 5 Peer to peer Network Connection GEL2 ESW10 GEL2 ESW12 GEL2 ESW08 GEPOESM ESW26 GEPoESM ESW26 Publication date Oct 2012 Revision A3 7 ...

Страница 16: ...Figure 6 Office Network Connection GEL2 ESW08 GEL2 ESW10 GELPoE2 ESW26 Publication date Oct 2012 Revision A3 8 ...

Страница 17: ... GEPOESM ESW26K Port Series Switch is connected to a separate grounded power outlet that provides 100 to 240 VAC 50 to 60 Hz ETHERNET CABLING To ensure proper operation when installing the switch into a network make sure that the current cables are suitable for 100BASE TX or 1000BASE T operation Check the following criteria against the current installation of your network Cable type Unshielded twi...

Страница 18: ...tely if any of the aforementioned items is missing or damaged WARNING The mini GBICs are Class 1 laser devices Avoid direct eye exposure to the beam coming from the transmit port MOUNTING The switch can be mounted in a standard 19 inch equipment rack or on a desktop or shelf Mounting instructions for each type of site as follow RACK MOUNTING Before rack mounting the switch please pay attention to ...

Страница 19: ... the device using the screws provided in the Mounting Accessory Figure 9 Attaching the Brackets Step2 Mount the device in the rack Via Optional Rack Mount kit using four rack mounting screws not provided Be sure to secure the lower rack mounting screws first to prevent the brackets being bent by the weight of the switch Figure 10 Installing the switch in a Rack Publication date Oct 2012 Revision A...

Страница 20: ... a single switch only turn to Connection to a Power Source at the end of this chapter Step4 If installing multiple switches mount them in the rack one below the other in any order Publication date Oct 2012 Revision A3 12 ...

Страница 21: ...adhesive feet to each one Place each device squarely on top of the one below in any order INSTALLING AN OPTIONAL SFP TRANSCEIVER You can install or remove a mini GBIC SFP from a mini GBIC slot Except GEL2 ESW08 without having to power off the switch Use only Manufacture mini GBIC NOTE The mini GBIC slots are shared with the two 10 100 1000Base T RJ 45 ports If a mini GBIC is installed in a slot th...

Страница 22: ...i GBIC CAUTION Use only supported genuine Manufacture mini GBICs with your switch Non Manufacture mini GBIC might have compatible issue and their use may result in product malfunction Publication date Oct 2012 Revision A3 14 ...

Страница 23: ...dule Bidi LC Single Mode 10km 1550nm SFP BL5 S20 1000Base LX GE SFP Fiber Module Bidi LC Single Mode 20km 1550nm SFP BL3 S20 1000Base LX GE SFP Fiber Module Bidi LC Single Mode 20km 1310nm SFP FLC 100Base FX FE SFP Fiber Module LC Multi Mode SFP FLC S20 100Base FX FE SFP Fiber Module LC Single Mode 20km CAUTION We recommend the SFP Transceiver from the following vendors Manufacture Corporation Agi...

Страница 24: ...nt panel LEDs as the device is powered on to be sure the POWER LED is lit If not check that the power cable is correctly plugged in WARNING For International use you may need to change the AC line cord You must use a line cord set that has been approved for the socket type in your country CONNECTING TO THE CONSOLE PORT The RJ 45 serial port on the switch s front panel is used to connect to the swi...

Страница 25: ...it data 3 RXD receive data 2 RXD receive data 5 SGND Signal ground 5 SGND Signal ground NOTE No other pins are used Figure 15 Plug in the Console Port The serial port s configuration requirements are as follows Default Baud rate 115 200 bps Character Size 8 Characters Parity None Stop bit One Data bits 8 Flow control none 2 TXD 5 GND 3 RXD Publication date Oct 2012 Revision A3 17 ...

Страница 26: ...l interface you can browse it For instance type http 192 168 1 1 in the address row in a browser it will show the following screen and ask you inputting username and password in order to login and access authentication The default username and password are both admin For the first time to use please enter the default username and password then click the Login button The login process now is comple...

Страница 27: ...an refer the detail in the User Guide Or you could access to the Switch and click the help under the web GUI and the switch will pop up the simple help content to teach you how to set the parameters GEPOESM ESW26K web help function Publication date Oct 2012 Revision A3 19 ...

Страница 28: ...ctions CABLING GUIDELINES The RJ 45 ports on the switch support automatic MDI MDI X pinout configuration so you can use standard straight through twisted pair cables to connect to any other network device PCs servers switches routers or hubs See Appendix B for further information on cabling CAUTION Do not plug a phone jack connector into an RJ 45 port This will damage the switch Use only twisted p...

Страница 29: ...rt will light green 1000 Mbps or amber 100 Mbps to indicate that the connection is valid NETWORK WIRING CONNECTIONS Today the punch down block is an integral part of many of the newer equipment racks It is actually part of the patch panel Instructions for making connections in the wiring closet with this type of equipment follows Step1 Attach one end of a patch cable to an available port on the sw...

Страница 30: ...move and keep the LC port s rubber plug When not connected to a fiber cable the rubber plug should be replaced to protect the optics Step2 Check that the fiber terminators are clean You can clean the cable plugs by wiping them gently with a clean tissue or cotton ball moistened with a little ethanol Dirty fiber terminators on fiber optic cables will impair the quality of the light transmitted thro...

Страница 31: ...he IEEE 802 3 2005 standards 1000 MBPS GIGABIT ETHERNET COLLISION DOMAIN Table 5 Maximum 1000BASE T Gigabit Ethernet Cable Length Cable Type Maximum Cable Length Connector Category 5 5e or 6 100 ohm UTP or STP 100 m 328 ft RJ 45 Table 6 Maximum 1000BASE SX Gigabit Fiber Cable Lengths Fiber Size Fiber Bandwidth Maximum Cable Length Connector 62 5 125 micron multimode fiber 160 MHz km 200 MHz km 220...

Страница 32: ...ST ETHERNET COLLISION DOMAIN Table 9 Maximum Fast Ethernet Cable Lengths Cable Type Maximum Cable Length Connector Category 5 5e or 6 100 ohm UTP or STP 100 m 328 ft RJ 45 Publication date Oct 2012 Revision A3 24 ...

Страница 33: ...ing your building s floor plans draw a map of the location of all network connected equipment For each piece of equipment identify the devices to which it is connected Note the length of each cable and the maximum cable length supported by the switch ports For ease of understanding use a location based key when assigning prefixes to your cable labeling Use sequential numbers for cables that origin...

Страница 34: ...e will not connect correctly to the switch The result will be high error rates and very inefficient communications between the switch and the device Make sure all devices connected to the GEPOESM ESW26K Switch devices are configured to auto negotiate or are configured to connect at half duplex all hubs are configured this way for example Faulty or loose cables Look for loose or obviously faulty co...

Страница 35: ...ER LED is Off Check connections between the switch the power cord and the wall outlet Contact your dealer for assistance Link LED is Off Verify that the switch and attached device are powered on Be sure the cable is plugged into the switch and corresponding device If the switch is installed in a rack check the connections to the punch down block and patch panel Verify that the proper cable types i...

Страница 36: ... functioning properly IN BAND ACCESS You can access the management agent in the switch from anywhere within the attached network using Telnet a web browser However you must first configure the switch with a valid IP address subnet mask and default gateway If you have trouble establishing a link to the management agent check to see if you have a valid network connection Then verify that you entered...

Страница 37: ...IN ASSIGNMENTS Use unshielded twisted pair UTP or shielded twisted pair STP cable for RJ 45 connections 100 ohm Category 3 or better cable for 10 Mbps connections or 100 ohm Category 5 or better cable for 100 Mbps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet The RJ 45 ports on the switch base unit support automatic MDI MDI X operation ...

Страница 38: ...upport Gigabit Ethernet Figure 20 Straight through Wiring EIA TIA 568B RJ 45 Wiring Standard 10 100BASE TX Straight through Cable CROSSOVER WIRING If the twisted pair cable is to join two ports and either both ports are labeled with an X MDI X or neither port is labeled with an X MDI a crossover must be implemented in the wiring When auto negotiation is enabled for any RJ 45 port on this switch yo...

Страница 39: ...ctional Pair B Minus BI_DB Bi directional Pair A Minus BI_DA 7 Bi directional Pair D Plus BI_DD Bi directional Pair C Plus BI_DC 8 Bi directional Pair D Minus BI_DD Bi directional Pair C Minus BI_DC CABLE TESTING FOR EXISTING CATEGORY 5 CABLE Installed Category 5 cabling must pass tests for Attenuation Near End Crosstalk NEXT and Far End Crosstalk FEXT This cable testing information is specified i...

Страница 40: ... spans and extended reach Optimized for wavelength division multiplexing WDM transmission across wavelengths from 1285 to 1625 nm The zero dispersion wavelength is in the 1310 nm region G 653 Dispersion Shifted Fiber Single mode 9 125 micron core Longer spans and extended reach Optimized for operation in the region from 1500 to 1600 nm G 654 1550 nm Loss Minimized Fiber Single mode 9 125 micron co...

Страница 41: ... 21 24 RJ 45 connector 100 1000M SFP GEPOESM ESW26K only Ports 25 26 100 1000M SFP ports GESM ESW26 GEPOESM ESW26K only BUFFER ARCHITECTURE 512KB on chip frame buffer AGGREGATE BANDWIDTH 52 Gbps for GESM ESW26 GEPOESM ESW26K SWITCHING DATABASE 8K MAC address entries LEDS System POWER TP Port status LINK ACT 10 100 1000M SFP Port status LINK ACT SPD 100 1000M WEIGHT 5 kg 11 02 lbs SIZE 44 H x 442 W...

Страница 42: ...port SOFTWARE LOADING HTTP TFTP in band Console out of band STANDARDS I EEE 802 3 10Base T Ethernet Twisted pair Copper IEEE 802 3u 100Base TX Ethernet Twisted pair Copper IEEE 802 3ab 1000Base TX Ethernet Twisted pair Copper IEEE 802 3z 1000Base X Ethernet IEEE 802 3x Flow Control Capability ANSI IEEE 802 3 Auto negotiation IEEE 802 1Q VLAN IEEE 802 1p Class of Service IEEE 802 1X Access Control ...

Страница 43: ...COMPLIANCES EMISSIONS EN55022 CISPR 22 Class A EN 61000 3 FCC Class A CE Mark IMMUNITY EN 61000 4 2 3 4 5 6 8 11 EN 55024 Publication date Oct 2012 Revision A3 35 ...

Страница 44: ...capabilities of the node to which it is connected BANDWIDTH The difference between the highest and lowest frequencies available for network signals Also synonymous with wire speed the actual speed of the data transmission along the cable COLLISION DOMAIN Single CSMA CD LAN segment CSMA CD CSMA CD Carrier Sense Multiple Access Collision Detect is the communication method employed by Ethernet Fast E...

Страница 45: ...3Z Defines CSMA CD access method and physical layer specifications for 1000BASE Gigabit Ethernet Now incorporated in IEEE 802 3 2005 LAN SEGMENT Separate LAN or collision domain LED Light emitting diode used for monitoring a device or network condition LOCAL AREA NETWORK LAN A group of interconnected computer and support devices MEDIA ACCESS CONTROL MAC A portion of the networking protocol that go...

Страница 46: ...o provide access to IP like services UDP packets are delivered just like IP packets connection less data grams that may be discarded before reaching their targets UDP is useful when TCP would be too complex too slow or just unnecessary UTP Unshielded twisted pair cable VIRTUAL LAN VLAN A Virtual LAN is a collection of network nodes that share the same collision domain regardless of their physical ...