background image

 

A

 

 

TROUBLESHOOTING 

 
 
 

Basic 

Troubleshooting 

Tips 

Most problems are caused by the following situations. 

Check for these items  first when starting your 

troubleshooting: 

 

Connecting to devices that have a fixed full- 

duplex configuration. 

The RJ-45 ports are configured as “Auto”. That is, when 

connecting to attach devices, the switch will operate in 

one of two ways to determine the link speed and the 

communication mode (half duplex or full duplex): 

 

If the connected device is also configured to Auto, 

the switch will automatically negotiate both link 

speed and communication mode. 

 

If the connected device has a fixed configuration, for 

example 100Mbps, at half or full duplex, the switch 

will automatically sense the link speed, but will 

default to a communication mode of half duplex. 

Because the GEL2P-ESW26G Switch devices behave in 

this way (in compliance with the IEEE802.3 standard), 

if a device connected to the switch has a fixed 

configuration at full duplex, the device will not connect 

correctly to the switch. The result will be high error 

rates and very inefficient communications between the 

switch and the device. 
Make sure all devices connected to the GEL2P-ESW26G 

Switch devices are configured to auto negotiate, or are 

configured to connect at half duplex (all hubs are 

configured this way, for example). 

 

Faulty or loose cables. 

Look for loose or obviously 

faulty connections. If they appear to be OK, make sure 

the connections are snug. If that does not correct the 

problem, try a different cable. 

 

Non-standard cables. 

Non-standard and miswired 

cables may cause network collisions and other network 

problems, and can seriously impair network 

performance. Use a new correctly-wired cable. For 

pinouts and correct cable wiring. A category 5 cable 

tester is a recommended tool for every 100Base-TX 

and 1000Base-T network installation. 

 

Improper Network Topologies. 

It is important to 

make sure you have a valid network topology. If you no 

longer experience the problems, the new topology is 

probably at fault. In addition, you should make sure 

that  your network topology contains 

no  data path 

loops.

 

  Revision A1

 

22 

Содержание GEL2P-ESW26G

Страница 1: ...GEL2P ESW26G Gigabit Managed Switch Installation and Getting Started Guide ...

Страница 2: ...INSTALLATION and GETTING STARTE GUIDE GEL2P ESW26G Gigabit Managed Switch Installation and Getting Started Guide Revision A1 i ...

Страница 3: ...following conventions are used throughout this guide to show information NOTE Emphasizes important information or calls your attention to related features or instructions WARNING Alerts you to a potential hazard that could cause personal injury CAUTION Alerts you to a potential hazard that could cause loss of data or damage the system or equipment WARRANTY See the Customer Support Warranty booklet...

Страница 4: ...se the user will be required to correct the interference at his own expense You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment You may use unshielded twisted pair UTP for RJ 45 connections Category 3 or better for 10 Mbps connections Category 5 or better for 100 Mbps connections Category ...

Страница 5: ...cate electronics Dry weather conditions or walking across a carpeted floor may cause you to acquire a static electrical charge To protect your device always Touch the metal chassis of your computer to ground the static electrical charge before you pick up the circuit device Pick up the device by holding it on the left and right edges only If you need using outdoor device connect to this device wit...

Страница 6: ... to each other To reduce the risk of electric shock Disconnect all AC or DC power cord and RPS cables to completely remove power from the unit Before importing exporting configuration please make sure the firmware version is always the same After firmware upgrade the switch will remove the configuration automatically to latest firmware version RELATED PUBLICATIONS The following publication gives s...

Страница 7: ...IPMENT CHECKLIST 7 PACKAGE CONTENTS 7 MOUNTING 7 INSTALLING AN OPTIONAL SFP TRANSCEIVER 10 CONNECTING TO A POWER SOURCE 14 CONNECTING TO THE CONSOLE PORT 14 Operation of Web based Management 16 MAKING NETWORK CONNECTIONS 17 CONNECTING NETWORK DEVICES 17 TWISTED PAIR DEVICES 17 FIBER OPTIC SFP DEVICES 18 CABLE LABELING AND CONNECTION RECORDS 21 TROUBLESHOOTING 22 Basic Troubleshooting Tips 22 POWER...

Страница 8: ...IN BAND ACCESS 24 SPECIFICATIONS 25 PHYSICAL CHARACTERISTICS 25 SWITCH FEATURES 25 MANAGEMENT FEATURES 26 STANDARDS 26 COMPLIANCES 26 Revision A1 vii ...

Страница 9: ... GEL2P ESW26G delivers 24 10M 100M 1G RJ45 ports 2 Combo GbE RJ45 SFP ports and RJ45 Console port GEL2P ESW26G provides high HW performance and environment flexibility for SMBs and Enterprises GEL2P ESW26G is ideal to deliver management simplicity optimum user experience and lower cost The embedded Device Managed System is designed to be extremely easy to use manage install IP Phone IP Cam or Wifi...

Страница 10: ...ked for validity before being forwarded This prevents errors from being propagated throughout the network NETWORK MANAGEMENT OPTIONS The switch can also be managed over the network with a web browser or Telnet application The switch includes a built in network management agent that allows it to be managed in band using SNMP or RMON Groups 1 2 3 9 protocols It also has an RJ45 console port connecto...

Страница 11: ...ted RJ 45 port is disabled The following table shows a list of transceiver types which have been tested with the switch For an updated list of vendors supplying these transceivers contact your local dealer For information on the recommended standards for fiber optic cabling see 1000 Mbps Gigabit Ethernet Collision Domain Supported SFP Transceivers Media Standard Fiber Diameter microns Wavelength n...

Страница 12: ... link on 10 100Mbps PoE Link ACT Green Lit Green when PoE link with PD and supply power to PD SFP SPEED Green Yellow Lit Green when SFP link on 1000Mbps Yellow when SFP link on 100Mbps Mode Status LEDs LED Condition Status Link ACT Speed Green Lit Green indicates all LED of each port are in Link ACT Speed mode System Status LED SYSTEM LED Condition Status Power Green OFF Lit green when power is co...

Страница 13: ...han it turns the hop count back to zero and removes the limitation A switch can be easily configured in any Ethernet Fast Ethernet or Gigabit Ethernet network to significantly increase bandwidth while using conventional cabling and network cards APPLICATION EXAMPLES The GEL2P ESW26G Switch implements 24 Gigabit Ethernet TP ports with auto MDIX and 2 slots for the removable SFP module GEL2P ESW26G ...

Страница 14: ...ake sure that GEL2P ESW26G 26Port Series Switch is connected to a separate grounded power outlet that provides 100 to 240 VAC 50 to 60 Hz ETHERNET CABLING To ensure proper operation when installing the switch into a network make sure that the current cables are suitable for 100BASE TX or 1000BASE T operation Check the following criteria against the current installation of your network Cable type U...

Страница 15: ...tely if any of the aforementioned items is missing or damaged WARNING The mini GBICs are Class 1 laser devices Avoid direct eye exposure to the beam coming from the transmit port MOUNTING The switch can be mounted in a standard 19 inch equipment rack or on a desktop or shelf Mounting instructions for each type of site as follow RACK MOUNTING Before rack mounting the switch please pay attention to ...

Страница 16: ... Attach the brackets to the device using the screws provided in the Mounting Accessory Attaching the Brackets Step2 Mount the device in the rack Via Optional Rack Mount kit using four rack mounting screws not provided Be sure to secure the lower rack mounting screws first to prevent the brackets being bent by the weight of the switch Installing the switch in a Rack Revision A1 8 ...

Страница 17: ... If installing a single switch only turn to Connection to a Power Source at the end of this chapter Step4 If installing multiple switches mount them in the rack one below the other in any order Revision A1 9 ...

Страница 18: ...o a Power Source at the end of this Chapter Step4 If installing multiple switches attach four adhesive feet to each one Place each device squarely on top of the one below in any order INSTALLING AN OPTIONAL SFP TRANSCEIVER You can install or remove a mini GBIC SFP from a mini GBIC slot without having to power off the switch Use only Manufacture mini GBIC NOTE The mini GBIC slots are shared with th...

Страница 19: ...upported Ensure the network cable is NOT connected when you install or remove a mini GBIC CAUTION Use only supported genuine Manufacture mini GBICs with your switch Non Manufacture mini GBIC might have compatible issue and their use may result in product malfunction Revision A1 11 ...

Страница 20: ...le Bidi LC Single Mode 10km 1550nm 1000Base LX GE SFP Fiber Module Bidi LC Single Mode 20km 1550nm 1000Base LX GE SFP Fiber Module Bidi LC Single Mode 20km 1310nm 100Base FX FE SFP Fiber Module LC Multi Mode 100Base FX FE SFP Fiber Module LC Single Mode 20km CAUTION We recommend the SFP Transceiver from the following vendors Manufacture Corporation Agilient Technologies AVAGO Technologies Finisar ...

Страница 21: ...be installed in one orientation Revision A1 13 ...

Страница 22: ... the front panel LEDs as the device is powered on to be sure the POWER LED is lit If not check that the power cable is correctly plugged in WARNING For International use you may need to change the AC line cord You must use a line cord set that has been approved for the socket type in your country CONNECTING TO THE CONSOLE PORT The RJ 45 serial port on the switch s front panel is used to connect to...

Страница 23: ...XD transmit data 3 TXD transmit data 2 RXD receive data 5 SGND Signal ground 5 SGND Signal ground NOTE No other pins are used Plug in the Console Port The serial port s configuration requirements are as follows Default Baud rate 115 200 bps Character Size 8 Characters Parity None Stop bit One Data bits 8 Flow control none 2 TXD 5 GND 3 RXD Revision A1 15 ...

Страница 24: ...ia the switch s serial interface you can browse it For instance type http 192 168 1 1 in the address row in a browser it will show the following screen and ask you inputting username and password in order to login and access authentication The default username is admin and password is empty For the first time to use please enter the default username and password and then click the Login button The...

Страница 25: ...s Category 5 or better for 100BASE TX connections CABLING GUIDELINES The RJ 45 ports on the switch support automatic MDI MDI X pinout configuration so you can use standard straight through twisted pair cables to connect to any other network device PCs servers switches routers or hubs CAUTION Do not plug a phone jack connector into an RJ 45 port This will damage the switch Use only twisted pair cab...

Страница 26: ...corresponding to each port will light green 1000 Mbps or amber 100 Mbps to indicate that the connection is valid NETWORK WIRING CONNECTIONS Today the punch down block is an integral part of many of the newer equipment racks It is actually part of the patch panel Instructions for making connections in the wiring closet with this type of equipment follows Step1 Attach one end of a patch cable to an ...

Страница 27: ...SFP transceiver Step1 Remove and keep the LC port s rubber plug When not connected to a fiber cable the rubber plug should be replaced to protect the optics Step2 Check that the fiber terminators are clean You can clean the cable plugs by wiping them gently with a clean tissue or cotton ball moistened with a little ethanol Dirty fiber terminators on fiber optic cables will impair the quality of th...

Страница 28: ... sure that it complies with the IEEE 802 3 2005 standards 1000 MBPS GIGABIT ETHERNET COLLISION DOMAIN Maximum 1000BASE T Gigabit Ethernet Cable Length Cable Type Maximum Cable Length Connector Category 5 5e or 6 100 ohm UTP or STP 100 m 328 ft RJ 45 Maximum 1000BASE SX Gigabit Fiber Cable Lengths Fiber Size Fiber Bandwidth Maximum Cable Length Connector 62 5 125 micron multimode fiber 160 MHz km 2...

Страница 29: ...100 MBPS FAST ETHERNET COLLISION DOMAIN Maximum Fast Ethernet Cable Lengths Cable Type Maximum Cable Length Connector Category 5 5e or 6 100 ohm UTP or STP 100 m 328 ft RJ 45 Revision A1 20 ...

Страница 30: ...each cable Using your building s floor plans draw a map of the location of all network connected equipment For each piece of equipment identify the devices to which it is connected Note the length of each cable and the maximum cable length supported by the switch ports For ease of understanding use a location based key when assigning prefixes to your cable labeling Use sequential numbers for cable...

Страница 31: ...lex the device will not connect correctly to the switch The result will be high error rates and very inefficient communications between the switch and the device Make sure all devices connected to the GEL2P ESW26G Switch devices are configured to auto negotiate or are configured to connect at half duplex all hubs are configured this way for example Faulty or loose cables Look for loose or obviousl...

Страница 32: ...ction POWER LED is Off Check connections between the switch the power cord and the wall outlet Contact your dealer for assistance Link LED is Off Verify that the switch and attached device are powered on Be sure the cable is plugged into the switch and corresponding device If the switch is installed in a rack check the connections to the punch down block and patch panel Verify that the proper cabl...

Страница 33: ...omponents are functioning properly IN BAND ACCESS You can access the management agent in the switch from anywhere within the attached network using Telnet a web browser However you must first configure the switch with a valid IP address subnet mask and default gateway If you have trouble establishing a link to the management agent check to see if you have a valid network connection Then verify tha...

Страница 34: ... Maximum Cable Length 100 m 328 ft Ports 25 26 100 1000M SFP ports BUFFER ARCHITECTURE 512KB on chip frame buffer AGGREGATE BANDWIDTH 52 Gbps for GEL2P ESW26G SWITCHING DATABASE 8K MAC address entries LEDS System POWER TP Port status LINK ACT 10 100 1000M SFP Port status LINK ACT SPD 100 1000M SIZE 44 H x 442 W x 211 2 D mm TEMPERATURE Operating 0 C to 45 C 32 F to 113 F HUMIDITY Operating 10 to 9...

Страница 35: ...2 3ab 1000Base TX Ethernet Twisted pair Copper IEEE 802 3z 1000Base X Ethernet IEEE 802 3x Flow Control Capability ANSI IEEE 802 3 Auto negotiation IEEE 802 1Q VLAN IEEE 802 1p Class of Service IEEE 802 1X Access Control IEEE 802 1D Spanning Tree IEEE 802 1w Rapid Spanning Tree IEEE 802 1s Multiple Spanning Tree IEEE 802 3ad ink Aggregation Control Protocol LACP IEEE 802 1AB Link Layer Discovery P...

Отзывы: