Charging Management
13
LCD Display
Description
Bypass mode
The inverter is working without DC/INV operation and
connecting to the loads.
PV power is not detected or
available. Only utility is charging
battery and providing power to
connected loads. icon is
flashing.
PV power and battery are not
detected or available to use at
this moment. Only utility is
available to provide power to
connected loads. and
icons are flashing.
LCD Display
Battery type
Sealed lead acid
battery
AGM/Gel battery
Bulk Charging Voltage
56
53.6 V
56.4
54.0 V
Recommended floating
charging voltage
Description
Standby mode :
The inverter is working without DC/INV operation and load
connected.
This inverter can connect to battery types of Sealed lead acid
battery, Vented battery and Gel battery. Below is recommended
bulk charging voltage and floating charging voltage table based
on different battery types.
The utility is out of range. This
inverter is disabled on AC output
or even AC power output is
enabled, but an error occurs on
AC output. Only PV power is
sufficient to charge battery.
icon is flashing.
This inverter is disabled to
generate power to the loads via
AC output. PV power is not
detected or available at this
moment. Only utility is available
to charge battery. icon is
flashing.
This inverter is disabled to
generate power to the loads via
AC output connector. PV power
and the utility are not detected
or available at this moment.
Three icons are flashing.
Charging voltage
Default
Value
25A
54.0 Vdc
56.0 Vdc
60.0 Vdc
Max. charging current
Battery overcharge protection
Max. absorption charging
voltage(default)
Floating charging voltage
(default)
Note
This can be adjusted via
software from 5Amp to
25Amp.
It can be adjusted via
software from 50Vac to
58Vdc.
It can be adjusted via
software from 50Vac to
58Vdc.
This value is 2 Vdc higher
than max. charging voltage.
Charging process based on
default setting.
3 stages:
First – max. charging voltage
increases to 56V;
Second- charging voltage will
maintain at 56V until charging
current is down to 5 Amp;
Third- go to floating charging
at 54V.
35