PROBLEMS
CAUSES
SOLUTIONS
The programmer does not regenerate
automatically or when the start up
button is pushed
Power supply disconnected
Connect
Damaged engine
Replace engine
Damaged card
Replace card
The programmer does not regenerate
automatically but only by pushing the
start up button
Daily regeneration has not been set
Set up regeneration
Lack of softened water between
two cycles
Incorrect regeneration
Repeat the regeneration cycle checking
that the correct amount of salt is provided
Polluted resins
Wash or replace resins
Wrong set up of the quantity of salt
Check and set up again
Mixing screw too fastened
Unfasten and check hardness
External by-pass, if present, open
Close by-pass
Failure in brine suction
Insufficient input pressure
Set at least 1.4 bar
Output pipe blocked
Remove obstruction
Obstructed injector
Clean injector
Damaged injector
Replace
Valves 2 and 6 blocked in
the open position
Remove the cause of the block
Valve line not sealed
Replace the whole valve line
An excessive quantity of brine is fed
into the tub
Valve 1 remains open
Manually activate the valve to remove
the cause of the block
The input speed has not been checked
Remove and clean the adjuster
Valve 2 does not remain closed during
suction
Manually activate the valve to remove
the cause of the block
Air suction in the connection pipe to
the tub
Check the tightness of brine connector
and pipes
Excessive quantity of salt set
Set up again following the indications of
the relevant table
Salt consumption not corresponding to
what is foreseen
Wrong adjustment
Set up again
Damaging bodies in the brine flowmetre
Remove and clean the flowmetre
Intermittent or irregular brine suction
Insufficient input pressure
Set at least 1.4 bar
Damaged injector
Replace injector
After regeneration water has not been
softened
The softener did not regenerate
Repeat regeneration
Salt shortage in the tub
Refill the salt in the tub
Lack of resins
Replace resins
Excessive or insufficient capacity of the
counter-washing
Wrong type of adjuster
Replace
The adjuster is obstructed
Remove and clean
Water comes out from the tub after
regeneration
Membrane 1 remains open
Manually activate it to remove
impurities blocking it or replace the
membrane series
Hard operation water seeping
Wrong regeneration
Repeat regeneration
O-ring 44F damaged
Replace
External by-pass, if present, open or
mixing screw adjusted incorrectly
Close the by-pass or adjust the mixing
screw