REO REOVIB 51310 Скачать руководство пользователя страница 3

 
Operating Instructions 

REOVIB 51310

 

 

 

1.0 Description  

Track control units for regulating the material reservoir on a feed track. Nearly all propriety initiators, 
active light barriers or Namur transducers can be installed.  The switching characteristics (PNP / NPN – 
output) can be adjusted on a front panel selector. 
 

2.0 Function  

The material demand is controlled by a sensor, the signal of which passes through two, independent, 
variable time delays (on and off switching delays), before enabling the output, which, for example, 
actuates the thyristor control. 
If the sensor is uncovered (No reservoir build up) and the adjustable switch on time delay has expired, the 
513 enables the power output of a thyristor controller. When the components cover the sensor, the switch 
off time delay starts and after this expires, the power output of the thyristor control is switched off. Gaps in 
the material flow are subject to control by the i ntegral timers, so that there is consistent timing between 
the last component and the first component. 
 
The on and off switching time delays can be adjusted with trimmers on the front panel of the unit, within 
the range of 0.5 – 15 seconds.  The status of the sensors (energised/de-energised) and also the enable 
output (on/off) is indicated on LED’s.  
 
A relay switches changeover contacts, in addition to the enable output, and this is brought out to 
terminals.  These contacts can be used to initiate other processes or supervisory equipment. 
 

3.0 

Technical Data 

 
Gerätetype 

 

Supply Voltage 

230 V +6% -15%, 50/60 Hz (110V Optional) 

Sensor operating Voltage  approx. 24 V, DC 
Sensor types 

Inductive, Capacitive, Namur, Active Light Barriers 

Switching Characteristics   PNP, NPN switchable 
Sensor Current 

100 mA  

Switch on delay 

0.5 – 15 secs 

Switch of time delay  

0.5 – 15 secs 

Anbient temperature 

0 –45 

°

Dimensions (l x w x h)  

80 x 45 x 114 

Relay contact 

2 A / 250 V 

Screw or Snap fixing (DIN rail EN 50022-35) 
Touch protection to VBG 4 
 

4.0 Declaration of Conformity 

We declare that these products, as stand-alone equipment, conform to the following standards 
or subsequent documents: EN 50081-2 and EN 50082-2 in accordance with 89/336/EWG 
regulations. 

 
REO ELEKTRONIK GMBH, D-42657 Solingen 
 

Содержание REOVIB 51310

Страница 1: ...ler REOVIBFOR VIBRATORY FEEDER SYSTEMS Sales and Distrubtion Developement Sales 8450 E 47th Street Brühler Straße 100 Indianapolis IN 46226 D 42657 Solingen Ph 317 899 1395 Tel 0212 8804 0 Fax 317 899 1396 Fax 0212 8804 188 http www reo usa com http www reo de eMail info reo usa com eMail info reo de ...

Страница 2: ...before installation or dismantling work as well as for fuse changes or post installation modifications Observe the prescribed accident prevention and safety rules for the specific application Before putting into operation check if the rated voltage for the unit conforms with the local supply voltage Emergency stop devices must be provided for all applications Operation of the emergency stop must i...

Страница 3: ...ast component and the first component The on and off switching time delays can be adjusted with trimmers on the front panel of the unit within the range of 0 5 15 seconds The status of the sensors energised de energised and also the enable output on off is indicated on LED s A relay switches changeover contacts in addition to the enable output and this is brought out to terminals These contacts ca...

Страница 4: ...PNP PNP bzw NPN NPN PNP PNP 1 2 S1 1 2 1 2 L PE 230V 6 10 Namur Sensor Sensor aktively switching PNP NPN Feeder on off to the thyristorcontroler time on delay time off delay setpoint Namursensor Sensor switch PNP output NPN output Namur LED Sensorcontrol LED output 2 1 3 Interner Wechsler Potentialfrei 1 Toff Ton 513 2 3 4 5 8 9 10 ELEKTRONIK 6 7 NA Sensor Output 11 N NPN NPN Thyristorcontroler on...

Отзывы: