Operating Instructions 

REOVIB 51310

 

 

 

Technical Safety Information for the User  

 

This description contains the necessary information for the correct application of the product described 
below. It is intended for use by technically qualified personal. 
 
Qualified personnel are persons who, because of their training, experience and position as well as their 
knowledge of appropriate standards, regulations, health and safety requirements and working conditions, 
are authorised to be responsible for the safety of the equipment, at all times, whilst carrying out their 
normal duties and are therefore aware of, and can report, possible hazards (Definition of qualified 
employees according to IEC 364) 
 

Safety Instructions 
 

The following instructions are provided for the personal safety of operators and also for the protection of 
the described product and connected equipment. 
 

Warning! 

Hazardous Voltage 
Failure to observe can kill, cause serious injury or damage 

 
 

• 

Isolate from mains before installation or dismantling work, as well as for fuse changes or post 
installation modifications. 

• 

Observe the prescribed accident prevention and safety rules for the specific application. 

• 

Before putting into operation check if the rated voltage for the unit conforms with the local supply 
voltage. 

• 

Emergency stop devices must be provided for all applications. Operation of the emergency stop must 
inhibit any further uncontrolled operation. 

• 

Electrical connections must be covered

 

• 

The earth connection must be checked, for correct function, after installation.

 

• 

After switching off the unit, some internal components will still be charged due to capacitance.

 

• 

Before opening the unit wait at least five minutes to allow capacitors to discharge. 

 

 

Specified Use 

 
The units described herein are electrical controllers for installation in industrial plant. 
They are designed for power adjustment on vibratory feed equipment. 
 

The units conform to the directive 89/336/EWG  

EMC - Directive   

 

 
 
Contents 
 
Technical Safety Information for the User ............................................................................................ 1

 

1.0 Description................................................................................................................................... 2

 

2.0 Function....................................................................................................................................... 2

 

3.0 

Technical Data

............................................................................................................................... 2

 

4.0 Declaration of Conformity.............................................................................................................. 2

 

5.0 Connections ................................................................................................................................. 3

 

6.0 Dimensions .................................................................................................................................. 3

 

7.0 Ordering Codes............................................................................................................................ 3

 

 

!

 

Содержание REOVIB 51310

Страница 1: ...ler REOVIBFOR VIBRATORY FEEDER SYSTEMS Sales and Distrubtion Developement Sales 8450 E 47th Street Brühler Straße 100 Indianapolis IN 46226 D 42657 Solingen Ph 317 899 1395 Tel 0212 8804 0 Fax 317 899 1396 Fax 0212 8804 188 http www reo usa com http www reo de eMail info reo usa com eMail info reo de ...

Страница 2: ...before installation or dismantling work as well as for fuse changes or post installation modifications Observe the prescribed accident prevention and safety rules for the specific application Before putting into operation check if the rated voltage for the unit conforms with the local supply voltage Emergency stop devices must be provided for all applications Operation of the emergency stop must i...

Страница 3: ...ast component and the first component The on and off switching time delays can be adjusted with trimmers on the front panel of the unit within the range of 0 5 15 seconds The status of the sensors energised de energised and also the enable output on off is indicated on LED s A relay switches changeover contacts in addition to the enable output and this is brought out to terminals These contacts ca...

Страница 4: ...PNP PNP bzw NPN NPN PNP PNP 1 2 S1 1 2 1 2 L PE 230V 6 10 Namur Sensor Sensor aktively switching PNP NPN Feeder on off to the thyristorcontroler time on delay time off delay setpoint Namursensor Sensor switch PNP output NPN output Namur LED Sensorcontrol LED output 2 1 3 Interner Wechsler Potentialfrei 1 Toff Ton 513 2 3 4 5 8 9 10 ELEKTRONIK 6 7 NA Sensor Output 11 N NPN NPN Thyristorcontroler on...

Отзывы: