Operating Instructions
REOTRON SMP
3
ELEKTRONIK
1.0
General
Primary switching circuit with DC output. Internal regulator for voltage, current or power control.
Controlled from two setpoints (setpoint 1 = voltage, setpoint 2 = current) using either a 0...10 V, 0(4)...20
mA analogue signal or a Potentiometer. Setpoint 1 is used in the power regulation mode. The touch panel
is used for making settings and keys “I“ and “O“ can be used for switching the output ON and OFF
.
However, this does not provide isolation of the mains input.
The units can be used in parallel or
series connection for providing higher power outputs.
Operating principles
2.0 Functions
Input:
Terminals
Set point 1
Voltage set point: 0...10 V, DC, 0(4)...20 mA or
Potentiometer 10 k
Or power set point
1(-), 3(+), 4(+10V) /
2 (+) for 0...20 mA
Set point 2
Current set point: 0...10 V, DC, 0(4)...20 mA or
Potentiometer 10 k
5(-), 7(+), 8(+10V) /
6 for 0...20 mA
Enable
Contact or 24 V, DC signal voltage
31(-), 32(+), 33(+24V)
Enable:
24 V, DC signal on enable input ( 24V = ON).
External contact on terminals 32 and 33 or external 24 V signal on terminals 31(-) and 32(+).
Voltage regulation (Set point 1)
Set point 2 (Current) at +10V Ref. Link between terminals 7 and 8.
Connect voltage set point to terminals 1 – 4 (see connection diagram).
A maximum output current limit can be set in menu “C. 020“.
Current regulation (Set point 2)
Set point 1 (voltage) at +10V Ref. Link between terminals 3 and 4.
Connect voltage set point to terminals 5 - 8 (see connection diagram).
A maximum voltage limit can be set in menu “C. 020“.
Power regulation (Set point 1)
Set point 2 (Current) at +10V Ref. Link between terminals 7 and 8.
Connect power set point to terminals 1 – 4 (see connection diagram).
A maximum output current limit can be set in menu “C. 020“.
~
=
=
=
U
I
+
-
Ua
Ue
Control unit
I
0
F
P