When installing the pump, be mindful of the pump’s center of gravity and weight. Failure to do so,
may result in the pump to fall and break which may lead to injury.
• This pump is
NOT
designed for applications involving Acid, or Alkaline.
• NEVER
, operate the pump dry. Doing do so will damage the seals and overheat the motor.
•
The pump contains parts that rotate at high speeds. Be careful around this pump base while
the pump is energized. Ensure that the pump is either in the pit / tank or clear from people, wires
when in operation.
This manual does not fully cover all safety issues. For this reason, the person using or maintaining
the pump must pay special attention to their own safety as well as those around.
CAUTION
3
PUMP IDENTIFICATION
3
Please check the nameplate on the received pump against your ordered pump. Paying special
attention to the Model, Output(Hp), Amperage, Voltage and Frequency.
• ALWAYS
, place the pump in an upright position. Ensure, that the pump will not burrow itself on
the soft sand or mud.
• NEVER
, allow the pump to freeze in the liquid it is pumping.
NOTICE
INSTALLATION
4
PUMP MOUNT
•
When connecting the discharge pipe / garden hose,
DO NOT
use a check valve on the discharge
line as it may lead to an Airlock.
NOTICE
PIPING
2.5
2.5