Catch Tray. Fit two end caps into the 
glue roll and fit into the right hand side of 
the Catch. Pull sufficient paper from the 
reel to reach the drive reel and wind the 
paper on until the film is securely fitted 
and tensioned. (Fig. 5) 

Replace the Catch Tray with the gear to 
the left of the unit (Fig. 6) 

Refit the cover to the unit. (Fig. 7) 

CLEANING 

Note: Disconnect the unit from the 
power supply before cleaning 

Remove any dead insects from the 
enclosure. Clean all surfaces that come 
into contact with the film using white 
spirit and remove all traces of adhesive. 
Clean the outside of the unit case with a 
paper window cleaning cloth. 

U.V. LAMP REPLACEMENT 

Although to our eyes the appearance of 
the lighted lamps may not change, their 
UV light output will reduce with time. To 
maintain the efficiency of the unit the 
three UV lamps must be replaced 
annually. 

Unplug the mains power cable and open 
the front of the unit. Skin or eye damage 
may result from directly viewing the 
lamps. This product is provided with an 
interlock/micro switch to reduce the risk 
of excessive UV radiation. Do not defeat 
the purpose or attempt to service without 
removing the cover completely. 

  

Carefully remove the lamp holder covers  
at each end of the UV lamp. The inner 
halves will be positioned  on the lamps 
during removal so care must be taken to 
retain them.. Rotate each lamp a quarter 
turn and withdraw the lamps forward and 

remove the loose lamp holder covers. 
(Fig. 10) 

 

Figure 10 

To install new lamps reverse the above 
lamp  removal procedure. The lamp 
holder cover inner halves must be fitted 
over the UV lamps prior to fitting of the 
lamps  –  the outer halves must be fitted 
after the lamps  have been located in 
their holders. Please take care to ensure 
the small lamp  tube holder cover parts 
are retained during service visits. 

Only 

replace lamps with  lamps of the type 
supplied with the unit i.e. PHILIPS 
LIGHTING  B.V., Type TL 15W 15W/Act, 
with shatterproof sheathing
 

If a lamp fails to light, a faulty starter 
normally causes the problem. The 
starters are situated in holder beside the 
lamps. To replace  a starter, turn each a 
quarter turn anticlockwise and withdraw. 
Then replace with a new one. 

Note: 

 The 

3 lamps are controlled by 3 starters type 
FS-2 

Содержание Luminos 3 Plus

Страница 1: ...1 MODEL Luminos 3 Plus Wall Mounted Model INSTRUCTION MANUAL ...

Страница 2: ... mechanical adjustment g To reduce the risk of electrical shock do not put this product in water or other liquid Do not place or store appliance where it can fall or be pulled into a tub or sink h Always unplug before replacing the lamp Replace bulb with same type rated 15 Watts i Connect to a properly grounded outlet only See Grounding Instructions INSTRUCTIONS PERTAINING TO A RISK OF FIRE ELECTR...

Страница 3: ...ct sunlight including roofed but open porches ATTENTION Replacing the control film starters and lamps may be performed by the user All other repairs and maintenance must be performed by qualified personnel Disconnect the product from the power source when not in use before servicing when changing tubes and cleaning Store the unit indoors when not in use out of reach of children Do not abuse the ma...

Страница 4: ...ed with a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances DANGER Improper connection of the equipment grounding conductor can result in a risk of electric shock The conductor with insulation having an outer surface that is green with or wit...

Страница 5: ...ugh clearance in front and above at least 60mm the front cover to allow it to open up for ease of servicing 2 Place the unit as far as possible from windows to minimize the competition from daylight 3 DO NOT place the unit directly over sources of heat since these may damage the cable installation 4 DO NOT position directly over areas where food is prepared or uncovered food is stored 5 CAUTION Ri...

Страница 6: ...rene Type SJT 5 Should it be necessary to remove the plug connector to make an alternative connection to the mains supply ensure that the following color code is strictly adhered to BLACK Live WHITE Neutral GREEN YELLOW Earth 6 Make sure that the supply cable is out of reach of children The severed plug connector should be destroyed to prevent accident WARNING ENSURE THAT THE UNIT CAN BE BOTH SWIT...

Страница 7: ... the reel to reach the drive reel and manually wind the paper on until the glue on the upper surface is securely fitted Manually advance the film until the adhesive coating reaches the drive shaft keeping the roll under tension Fig 5 Note The glueboard should only be used if there is a heavy infestation of flies Figure 5 Place the Catch Tray back into the unit holes in the tray align with studs in...

Страница 8: ...he film until it leaves the left spool and totally winds onto the right spool If a glue board has been installed this should be removed and replaced First remove the Cover and lift out the Catch Tray as described in the section Setting Up And Operation Fig 1 2 If required release the glue board from the central tab and slide out and discard or retain for counting Fig 8 Figure 8 If required refit a...

Страница 9: ...interlock micro switch to reduce the risk of excessive UV radiation Do not defeat the purpose or attempt to service without removing the cover completely Carefully remove the lamp holder covers at each end of the UV lamp The inner halves will be positioned on the lamps during removal so care must be taken to retain them Rotate each lamp a quarter turn and withdraw the lamps forward and remove the ...

Страница 10: ... the supply cable to the unit then remove the motor cover plate situated bottom left from the unit by unscrewing the 5 self tapping screws 2 on the front 2 on the back and 1 on the base Carefully lift the motor cover plate off taking care not to damage internal wiring Carefully remove the fuse located at the inboard end of the control circuit board and replace with a 20mm 1 amp quick blow fuse SCH...

Страница 11: ... 120V 60 Hz Power Consumption 91mA 120V 60Hz Internal Fuse 20mm 1 Amp Quick Blow Size Inch mm W 20 510 x H 15 380 x D 6 1 154 Weight lb kg Boxed 16 8 7 6 Unit 10 1 4 6 Conforms to the relevant sections of E345204 UL 73 EPA NUMBER F ...

Страница 12: ...12 Exploded View Parts Identification ...

Страница 13: ...m Screw 11 Module LH 12 Mirco Switch 13 Mirco Switch Cover 14 M2 Lock Nut 15 Ballast Cover 16 Conduit 17 Back 18 Strain Relief Bush 19 M3x8 Screw 20 Bush 21 Washer 22 M4 Lock Nut 23 ψ4 2 INT Tooth Washer 24 Wiring Harness 25 M4x8 Screw 26 Module RH 27 Lamp 28 End Spool 29 Terminal Block 30 M3x12 Screw 31 Core Extrusion 32 Drive Gear 33 M5 Wing Nut 34 Film Guide 35 Motor 36 PCB 37 34 Tooth Gear 38 ...

Страница 14: ...14 Manufactured for Rentokil made in Vietnam Number 363204 Revision 1 0 30 01 2012 ...

Отзывы: