3 INSTALLATION GUIDE
Switch power supply parameter setting
After installation, test for short-circuits. If not, you can switch on the electricity.
Switching power supply module parameters should be set according to the following
table:
Table 3-5 Switch power supply parameter setting
Item
Parameters:
Cyclic use 24V
Parameters:
Cyclic use 48V
Notes
Charge voltage
(
CV
)
27.6V
55.2V
When the charging
current is less than
0.01C,The battery will
be stopped to charge.
Low voltage
disconnect
≥
22V (23V)
≥
44.0V (45-46V)
Charge current
≤0.2C/Module
≤0.2C/Mod
ule
If the current
exceeds
0.2C/Module
please contact
our technical
1)
The BMS is factory set for limited charging current when used in parallel operation
with the RS485 cables connected. If comms cables are not connected, the maximum
charge current for each battery pack must be programmed to 0.2C. For detailed
operations, please refer to Integrated Lithium-ion Battery Pack PC Software User
Manual.
2)
Always start the power supply module first, then connect the load.