NSTALLATION AND 

M

AINTENANCE INSTRUCTIONS

 

 

 

 

 

 

Содержание Sensorex SX-CF Series

Страница 1: ...membranze 93 20099 Sesto San Giovanni Milano Italy tel 39 02 2700 7394 fax 39 02 2570 8635 www renova srl it email support renova srl it SX CF Series SX CH Series LOAD CELL MANUAL INSTALLATION AND MAI...

Страница 2: ...2 Copyright Renova Srl 2013 All rights reserved MANLOADCELLENA4V1117...

Страница 3: ...tructions page 5 how it works page 5 load cell exploded view page 6 unpacking page 6 flanged cell SX CF assembling through shaft cell SX CH assembling load cells and roll mounting load cells SX CF mod...

Страница 4: ...ife For a safe and proper use of this product please pay particular attention to the security precautions RENOVA srl warning CAREFULLY READ THE INSTRUCTIONS AND WARNINGS IN THIS MANUAL AND KEEP THEM F...

Страница 5: ...with Agents and Distributors Contact Renova support support renova srl it general instructions HOW IT WORKS The load cell is a transducer that converts the force applied by the roller on the bearing...

Страница 6: ...hat the package has not been damaged during transport Verify that the paper box contains the parts listed below and they correspond to the ordered cell whose code is silk screened onto the load cell b...

Страница 7: ...the same role of the arrow hence helping the correct orientation of the sensor Figure 2 Fix the flange of the cell onto the machine frame after checking the dimension of the centering and positions of...

Страница 8: ...ting screws following the specified tightening torque for the required type of screw Pay attention in this operation because a mistake in the correct mounting may lead in case of detachment of the cel...

Страница 9: ...C30 0015 J35 DIN472 A70 0004 RAM 35 A65 0001 1 2 Kg SXCF085 xxx 17 17x40x16 2203 2RS C30 0014 J40 DIN472 A70 0005 RAM 40 A65 0002 1 2 Kg SXCF085 xxx 20 20x47x18 2204 2RS C30 0016 J47 DIN472 A70 0003...

Страница 10: ...0 0001 VA 25 G90 0004 3 0 Kg SXCH125xxx 30 30x62x20 2206 2RS C30 0017 J62 DIN472 A70 0007 VA 30 G90 0005 2 7 Kg SXCH125xxx 35 35x80x31 6207 2RS C30 0024 J72 DIN472 A70 0008 VA 35 G90 0006 2 4 Kg SXCH1...

Страница 11: ...mA Standard cell connection Amplified cell connection wire color wire color Supply RED Supply RED Supply BLACK Supply BLACK Signal WHITE Signal GREEN Signal GREEN Technical data Precision class 0 5 R...