7
Multi-pin cable
1
Seeger
1
Block screw
4
* The mounting screws are not included
FLANGED CELL SX-CF ASSEMBLING
Please, carefully follow these assembling steps:
Mount the cell with the arrow, printed on the body of the cell itself, oriented in the same direction of the resultant
of the forces acting on the load cell. A red dot is printed onto the load cell body and has the same role of the arrow,
hence helping the correct orientation of the sensor. Figure 2
Fix the flange of the cell onto the machine frame after checking the dimension of the centering and positions of the
screws. In case the project foresees the presence of two opposing load cells, check their co-axiality. Lock firmly the
mounting screws, following the specified tightening torque for the required type of screw.
Pay attention in this operation because a mistake in the correct mounting may lead, in case of detachment of the
cells, to the break of the machine.
Figure 2