background image

- 09 -

Use the included MC4 to 5.5mm DC Adapter cable to connect the external solar panel to the DC Input Port of 
the PHOENIX Elite. Place the PHOENIX Elite in the shade to prevent it from overheating.

The PHOENIX Elite will begin to recharge automatically. The LCD Screen will be lit with the [Battery Level] 
icon and [Input Power] icon appearing.

Compatible External Solar Panels:

Renogy Monocrystalline Solar Panel: 

50W, 80W, 100W, 160W

Recharging via AC/DC Adapter

Plug the PHOENIX Elite into a wall outlet through the DC Input Port using the included AC/DC Adapter.

Renogy Polycrystalline Solar Panel: 

50W, 100W

Renogy ECLIPSE Series Solar Panel:

 100W

Renogy Monocrystalline Foldable Solar Suitcase w/o Controller: 

100W

Renogy ECLIPSE Series Foldable Solar Panel w/o Controller: 

100W, 200W

Renogy Flexible Solar Panel: 

50W, 100W, 160W, 175W

Renogy E.FLEX Series Portable Solar Panel: 

50W, 100W, 120W

CAUTION

WARNING

NOTE

Electrical shock can occur if the MC4 to 5.5mm DC Adapter Cable is damaged or frayed. DO 
NOT use a damaged or frayed cable to recharge the PHOENIX Elite.

Please ensure that the open circuit voltage of the external solar panel does not exceed 30V or 
fall short of 9V.

The recharge time via the external solar panel is highly dependent on solar irradiance and 
ambient temperature.

Содержание PHOENIX ELITE R300PHXE

Страница 1: ...PHOENIX ELITE PORTABLE SOLAR GENERATOR User Guide Model R300PHXE...

Страница 2: ...ETY INSTRUCTIONS PACKAGE CONTENTS FEATURES RECHARGING PHOENIX ELITE LCD SCREEN PRODUCT OVERVIEW SPECIFICATIONS TROUBLESHOOTING FREQUENTLY ASKED QUESTIONS WARRANTY OPERATING PHOENIX ELITE MAINTENANCE 1...

Страница 3: ...O NOT overload the unit Please check the specifications of output ports and devices before operation Please turn off the output ports when no devices are connected to the unit to prevent electric shoc...

Страница 4: ...mind the PHOENIX Elite supports recharging from car sockets AC adapters USB C wall chargers and external solar panels Equipped with a 300Wh rechargeable lithium ion battery pack and multiple output po...

Страница 5: ...PRODUCT OVERVIEW 04 7 6 1 2 3 4 5 8 9 10 11 12 13 14...

Страница 6: ...e Door 15 DC Input Port 16 USB C PD Port 17 LED Flashlight 18 Carrying Handle 19 14 13 12 11 10 9 Flashlight On Off Button Main Power Button AC Output Mode On Off Button DC Output Mode On Off Button L...

Страница 7: ...413 x 308 x 100 mm 16 3 x 12 1 x 3 9 inch 5 3 kg 11 7 lb ABS PC 3W LED 0 45 32 113 10 60 14 140 20 90 Dimension Weight Material Flashlight Normal Operating Temperature Storage Temperature Operating S...

Страница 8: ...rned on The rectangle disappears when the AC output mode is deactivated with the AC Outlet turned off AC Output Mode AC Output The DC Output Mode is displayed as a rectangle with the words DC Output i...

Страница 9: ...rge the PHOENIX Elite using the Built in Solar Panels on bright sunny days free of scattered clouds Recharging via External Solar Panel For optimal recharging performance it is highly recommended to r...

Страница 10: ...uded AC DC Adapter Renogy Polycrystalline Solar Panel 50W 100W Renogy ECLIPSE Series Solar Panel 100W Renogy Monocrystalline Foldable Solar Suitcase w o Controller 100W Renogy ECLIPSE Series Foldable...

Страница 11: ...icon appearing WARNING Electrical shock can occur if the AC DC Adapter is damaged DO NOT use a damaged AC DC Adapter to recharge the PHOENIX Elite WARNING DO NOT use a third party AC DC adapter to cha...

Страница 12: ...G Electrical shock can occur if the USB C PD wall charger is damaged DO NOT use a damaged USB C PD wall charger to recharge the PHOENIX Elite Recommended USB C PD Wall Chargers Apple USB C Power Adapt...

Страница 13: ...ut Mode On Off Button to deactivate the DC output mode The DC Output Mode icon and Output Power icon will disappear To use the AC Outlet first press the AC Output Mode On Off Button to activate the AC...

Страница 14: ...act information If the PHOENIX Elite is not used frequently keep its battery level at around 50 Store the PHOENIX Elite in a clean dry and well ventilated environment with a temperature around 77 25 a...

Страница 15: ...urce Check the voltage rating of the power source Connect only the power source with compliant voltage rating to the unit E08 DC Input Port Under voltage Disconnect the power source Check the voltage...

Страница 16: ...the Renogy technical support team for help E20 QC USB A Port Output Over voltage Disconnect the electrical load Reactivate the DC output mode If the Error Code icon persists stop using the unit Contac...

Страница 17: ...re Disconnect all the electrical load s Press the AC Output Mode On Off Button to clear the Error Code icon Reallocate the total output power E30 Total Output Overload FREQUENTLY ASKED QUESTIONS 1 Why...

Страница 18: ...ales services for products that are sold by RENOGY or retailers and distributors authorized by RENOGY If you have purchased your unit from other channels please contact your seller for more informatio...

Страница 19: ...USA 909 287 7111 www renogy com support renogy com https www renogy cn support renogy cn CN 400 6636 695 1 5 4 CA https ca renogy com supportca renogy com https au renogy com supportau renogy com AU...

Отзывы: