Protections, Troubleshooting and 

Maintenance

 

5.1 Protection  

PV Array Short Circuit  

If PV array short circuit occurs, clear it to resume normal operation.  

PV Overvoltage 

If  PV  Overvoltage  occurs,  the  array  will  remain  disconnected  until  the  voltage 
falls safely below the maximum rating. 

PV Overcurrent 

If PV Overcurrent occurs, the array will be disconnected automatically. 

Load Overload 

If  the  load  current  exceeds  the  maximum  load  current  rating,  the  controller  will 
disconnect the load. Reapplying power or pressing the setting button will clear up 
the overloading fault. 

Load Short Circuit 

Fully  protected  against  load  wiring  short-circuit.  After  one  automatic  load 
reconnect attempt. Reapplying power or pressing the setting button will clear the 
fault. 

PV Reverse Polarity 

Full protection against PV reverse polarity, no damage to the controller will result. 
Correct the wire connection to resume normal operation. 

Battery Reverse Polarity 

Full  protection  against  battery  reverse  polarity,  no  damage  to  the  controller  will 
result. Correct the wire connection to resume normal operation. 

Damaged Local Temperature Sensor 

If  the  temperature  sensor  short-circuited  or  damaged,  the  controller  will  be 
charging  or  discharging  at  the  default  temperature  25°C  to  prevent  the  battery 
damaged from overcharging or over discharged. 

Содержание MPPT20CC

Страница 1: ...MPPT20CC RENOGY 20A Maximum Power Point Tracking Solar Charge Controller Manual 14288 Central Ave Suite A Chino CA 91710 1 800 330 8678...

Страница 2: ...6 3 1 General Installation Notes 6 3 2 Mounting 6 3 3 Wiring 7 4 Operation 10 4 1 MPPT Technology 10 4 2 Battery Charging Information 12 4 3 LED Indications 13 4 4 Setting Operation 15 5 Protections...

Страница 3: ...ure for safe and proper operation of the controller NOTE Indicates a procedure or function that is important for the safe and proper operation of the controller General Safety Information Read all of...

Страница 4: ...king technology to optimize the use of the PV system Peak conversion efficiency of 97 high Tracking efficiency of 99 Fast sweeping of the entire I V curve several seconds tracking speed Widely used au...

Страница 5: ...tor 2 Battery Status LED indicator 3 Temperature Sensor 4 Setting Indicators 5 LED Digital Display the load work mode and status 6 Setting Button in manual mode used for load ON OFF 7 Solar Module Ter...

Страница 6: ...nformation is displayed on a backlit LCD display The large numerical display and icons are easy to read and large buttons make navigating the meter menus easy The meter can be flush mounted in a wall...

Страница 7: ...ials or even cause fire Ensure tight connections and use cable clamps to secure cables and prevent them from swaying in mobile applications Use with Gel Sealed or Flooded batteries only Battery connec...

Страница 8: ...Step 5 Secure Controller Place the controller on the surface and align the mounting holes with the drilled holes in step 4 Secure the controller in place using the mounting screws 3 3 Wiring NOTE A r...

Страница 9: ...terminal Do not insert a fuse at this time Confirm the connection correct and then turn on the power Step 2 Load Wiring The MPPT20CC load output can connect DC electronic devices of which the rated v...

Страница 10: ...rays Grid tie solar module s may be used if the open circuit voltage does not exceed the maximum solar input rating The solar module s nominal voltage must be equal to or greater than the nominal batt...

Страница 11: ...the following is true Power Into the controller Power Out of the controller Volts In Amps In Volts Out Amps Out Assuming 100 efficiency Actually the losses in wiring and conversion exist If the solar...

Страница 12: ...resulting in less wasted energy compared to traditional controllers Conditions that Limits the Effectiveness of MPPT The Vmp of a solar module decreases as the temperature of the module increases In...

Страница 13: ...r the Boost voltage stage MPPT20CC will reduce the battery voltage to float voltage set point When the battery is fully recharged there will be no more chemical reactions and all the charge current tr...

Страница 14: ...irements of the battery used in the system Certain types of batteries benefit from periodic equalizing charge which can stir the electrolyte balance battery voltage and complete chemical reaction Equa...

Страница 15: ...reen Flashing Full battery Orange On Solid Low battery Red On Solid Over Discharged battery Table 4 2 Battery LED indicators Please refer to Chapter 5 for troubleshooting PV Overvoltage Display If the...

Страница 16: ...erent seasons However it will take some time to learn it Notes When the OFF time set on Timer 2 is later than local sunrise time the controller will turn off the load output at sunrise Load Control Se...

Страница 17: ...he system installation 4 Manual Mode This mode is to turn on off the load by the Setting button Load Work Mode Setting Figure 4 5 Instruction figure on setting Press the setting button once and the se...

Страница 18: ...Load will be on for 13 hours after a ten minute delay since sunset 13 Load will be on for 14 hours after a ten minute delay since sunset 14 Load will be on for 15 hours after a ten minute delay since...

Страница 19: ...he battery type LED turns on The led will be flashing Continue to hold and the number will repeat from 1 to 3 and stop pressing until the desired number appears according to the following setting tabl...

Страница 20: ...rloading fault Load Short Circuit Fully protected against load wiring short circuit After one automatic load reconnect attempt Reapplying power or pressing the setting button will clear the fault PV R...

Страница 21: ...red Battery over discharged The controller cuts off the output automatically LED indicator will return to green automatically when fully charged LED digital display shows P PV Overvoltage Check wheth...

Страница 22: ...n or burnt wire connections Check and confirm that the LED digital display is consistent Pay attention to any troubleshooting or error indication Take necessary corrective action Confirm that all the...

Страница 23: ...of date and place of purchase To obtain rapid service under this warranty the returned products must include the model serial number and detailed reason for the failure the module type and size type...

Страница 24: ...remote meter MT 5 disconnected Battery Parameters Temp 25 C Control Parameter Battery Charging setting Gel Sealed Flooded High Volt Disconnect 16 0V x2 24V 16 0V x2 24V 16 0V x2 24V Charging Limit Vo...

Страница 25: ...tion of equalize boost float and low voltage disconnect voltage Environmental Parameters Environmental Parameter Ambient Temperature Range 35 C to 55 C Storage Temperature Range 35 C to 80 C Humidity...

Страница 26: ...PV Power Conversion Efficiency Curve Illumination Intensity 1000W m2 Temperature 25 C 1 Solar Module MPP Voltage 17V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V Nominal System Voltage 1...

Страница 27: ...26 3 Solar Module MPP Voltage 68V Nominal System Voltage 12V 4 Solar Module MPP Voltage 34V Nominal System Voltage 24V...

Страница 28: ...27 5 Solar Module MPP Voltage 68V Nominal System Voltage 24V...

Страница 29: ...28 MPPT20CC Dimensions mm...

Отзывы: