24
Maintenance
Fan Operation
STEP-10.1
STEP-10.2
z
Clean the fans regularly.
The accumulation of debris
and dust can block the
fans and affect the heat
dissipation of LYCAN.
z
The parameters of
thermostat have been
preset. No additional
parameter setting is
required.
z
DO NOT modify the
parameters of thermostat.
Modifying the parameters
can lead to irreversible
damage to LYCAN and
voids the warranty.
The fans are located at the
bottom of LYCAN. They
start operating when the
temperature of the air vent
rises above 131°F (55°C)
and stop operating when the
temperature of the air vent
drops below 113°F (45°C).
The thermostat is located next
to the fan and displays the
temperature of the air vent.
Inspection
Please perform regular inspections by following the steps below.
z
Examine the external appearance of LYCAN. The enclosure and connector contacts of LYCAN
shall be clean, dry, and free of corrosion.
z
Check the external cables and connections of LYCAN. Replace any damaged cables and tighten
any loose connections.
z
In some applications, corrosion can form around the contacts internal to the Anderson Connector.
The corrosion can cause loosening of spring retention force and increase of mated contact
resistance, leading to premature failure of the connection. Please apply dielectric grease onto
each connector contact at regular intervals. Dielectric grease can repel moisture and protect the
connector contact against corrosion.