889-1429-00 CPS-TS2E Operation Manual Rev Apr 2021 Page
2
24VDC DC output voltage and current draw) with a single glance. The user
interface consist of a large OLED display and three momentary push-buttons
for firmware navigation and data entry. As mentioned all measured data is
saved onto a flash micro-SD card. Additionally, there are four processor
independent (hardware integral) LEDs providing the continuous status of the
DC and AC output voltages and AC Line input even if there is a processor
failure.
Even if the processor fails and cannot be reset, the power supply
will continue to function without interruption of safe regulated voltages
to the traffic cabinet.
On the front panel of the CPS-TS2E, the traffic technician has six
colored test jacks providing direct measurements with a multimeter of all AC
and DC outputs.
Section 2 Specifications
A.
Physical
1.
Size:
3.4 inches wide x 7.1 inches high x 7.4 inches deep
2.
Weight:
2.71 pounds
3.
Front Panel Connector:
MS3106A-18-1SW
4.
Mounting:
Shelf
5.
Circuit Boards:
The printed circuit board is 0.062 inch thick FR4 material with
2 Oz. Copper. All holes are plated through. Circuit boards and components
are conformal coated with a polyurethane coating.
6.
Enclosure:
The enclosure is fabricated with powder coated alumi-num.
Attachment points are located on top and bottom for rigid mounting.
B.
Environmental
1.
Compliance:
NEMA TS-2 2003 Standards
2.
EMI Compliance:
Radiated and conductive emissions are in compliance
with FCC part 15, Class A
3.
Operating Ambient Temperature:
-40º C to +85º C
C.
Electrical Rating of Power Supply
1.
AC Line Input Voltage:
80 VAC to 150 VAC
2.
AC Line Input Frequency:
43 Hz to 65 Hz
3.
AC Line Regulation:
±0.1%
4.
Power Factor:
≥0.95
5.
Efficiency:
≥80%
6.
DC Outputs:
12 VDC ±2% @ 5 Amps and 24 VDC ±2% @ 5 Amps
7.
Output Ripple:
Less than 50 mV Peak to Peak