Page 13
Point Source Array Modules
RHAON Empowered VARIA Array Module Connections
The input panel shown is for the PF2-500R digital bi-amplifier used in the VA101-7-52R
The PF1-500R single channel amplifier used with the VA / VAX15S subwoofer input panel is identical
except for having only 1 mute switch and status LED. For more detailed information, please refer to
the Renkus-Heinz RHAON User’s Manual.
VAX15S subwoofers are shipped wired for fully passive operation using the internal crossover. The
crossover can be bypassed by removing the connector plate from the cabinet and changing several
internal connections. For detailed instructions, please refer to the Renkus-Heinz Loudspeaker User’s
Manual, form RH508.
Power LED
Thermal LED
AC Line Voltage
Selector
AC Line Fuse
IEC Power
Connector
AC Power
On/Off Switch
Primary Analog Input
XLR female
Looping Analog
Output
XLR male
Signal & Overdrive
LED Status Indicators
Input Pad &
LED Indicator
Push Button
Volume Controls
Mute Buttons
Primary & Secondary
Ethernet (CobraNet) Inputs
RJ-45 female
Secondary
Analog input &
Looping Output
Fault Detect
Fault Relay