This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the
technical status at the time of printing.
© Copyright 2015 by Conrad Electronic SE.
V2_0915_02-ETS-Mkd
Installation
Heed all information contained in the chapter “Preparing installation”.
• Use the foot of the product as a template and mark the drill hole positions through
the screw holes onto the installation surface.
When drilling or tightening screws, make sure not to damage any cables,
wires or pipes located underneath the surface.
• Drill the holes into the installation surface and insert the dowels into the drill holes.
• Carefully pull out the terminal block box from the bottom of the lamp housing.
• Remove the 4 screws from the lid of the box and then remove the lid.
• Remove the outer insulation of the mains cable to a length of maximum 16 mm. Then
remove the insulation of the 3 cables over a length of approx. 6 mm. The wire of the
protective ground conductor (yellow-green) should be at least 6 mm longer in size in
order for it to remain last in the terminal block in case of failure.
• Carefully cut a hole into the rubber sealing of the terminal block box and guide the
mains cable from outside through the hole.
Use an appropriate sealing agent (such as silicone) to seal up the hole if it
is too large.
• Connect the mains cable with the terminal block:
- Brown cable = L
- Blue cable = N
- Green/yellow cable = PE/ground wire, grounding symbol
The ground wire must be connected to the terminal block under all
circumstances.
If the product is serving as a replacement for an existing light and there
is no ground wire, do not install the product. First install the appropriate
supply leads.
If no ground wire is connected, there will be voltage applied to the metal
product housing in the event of an error. This poses a risk of fatal electric
shock!
Make sure that the cables are not bare for too long as this may cause short-
circuiting.
Make sure that all screw connections on both sides of the terminal block
are tight.
• Reinstall the lid of the terminal block box (observe the correct positioning of the
sealing) and secure it with the 4 screws.
• Reinsert the terminal block box back into the lamp.
• Align the foot of the product with the dowels and mount the product to the installation
surface using the screws provided.
Make sure that the cables are not squeezed, bent or damaged in any other
way. Do not exert any force when installing the product.
• Turn on power to the circuit and check to see if the product works.
If the LEDs do not light up, turn off power to the circuit immediately (turn off
circuit breaker and/or automatic fuse).
Then check the connection to the power circuit.
In case of doubt, contact a professional (i.e. an electrician).
Maintenance and cleaning
Never use aggressive cleaning agents or chemical solutions, as such would
damage the housing (discolorations).
Never point a water jet, for example such of high-pressure cleaning
equipment, at the lamp, as that could damage the seals!
• Besides occasional cleaning, the device is maintenance-free.
• Turn off the product and let it cool down sufficiently before cleaning.
• Clean the exterior surface with a clean, soft cloth only. Slightly dampen the cloth
with lukewarm water to remove stubborn stains.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the
household waste.
At the end of its service life, dispose of the product according to the
relevant statutory regulations.
You thus fulfil your statutory obligations and contribute to the protection of
the environment.
Technical data
Operating voltage................................220 – 240 V/AC, 50 Hz
Power consumption............................max. 10.5 W
Luminous flux .......................................900 lm
Illuminants ............................................60 LEDs
Colour temperature.............................2700- 3000 K
Protection class ..................................I
Protection type ....................................IP44
Material ................................................Stainless steel V2A
Operating conditions ..........................-40 to +55 ºC, 0 – 95 % RH
Storage conditions..............................-40 to +65 ºC, 0 – 95 % RH
Dimensions (Ø x H)..............................98 x 400 mm (item no. 1274644)
98 x 600 mm (item no. 1274683)
Weight ...................................................approx. 608 g (item no. 1274644)