Renkforce 751560 Скачать руководство пользователя страница 4

Installation and connection

a) Installation

 

Please follow the chapter “Safety Instructions”.

 Important!
 

 The motion detector may not be connected to the mains voltage. It is only suitable 

for an operating voltage of 12 V/DC.

 

 The relay is also not suitable for connecting to the mains voltage. Only a maximum 

voltage of 24 V/DC and a maximum current of 100 mA must be connected.

•  The motion detector must only be connected in a de-energised state. 
•  Only mount the motion detector with the wall holder to a solid base, 

e.g. masonry. Use screws and, if necessary, screw anchors that 

are suitable for the surface. We recommend a mounting height of 

2 to 3 m.

•  The motion detector must be installed such that it is out of the 

reach of children.

•  Paying attention to the correct position of the wall holder, mount 

the same using two suitable screws, and if required, wall plugs. 

The arrow in the image on the right marked “top”.

 Caution!
 

 Pay attention when drilling and tightening the screws that 

no cables or pipes are damaged!

•  Remove the circuit board of the motion detector from the housing 

after removing the screw (4).

•  There is no hole yet in the back of the housing for cable lead-

through.

  Drill a corresponding hole (A) in the imprint; the diameter depends 

on the connection cable used.

•  Mount the back of the housing to the wall holder using one of the 

screws provided. 

  It is helpful to either drill a little hole or to penetrate the plastic with 

a pointed object in this spot (B).

  Make sure that the hole does not get too big; otherwise, the back 

of the housing cannot be mounted on the wall holder.

•  Replace the circuit board and secure it with the screw (4) that you 

removed earlier.

•  Guide the connection cable through the hole drilled earlier (A).

b) Connection

Screw terminals “DC12 V +/-”

Connect these two screw terminals with the voltage/power supply, 

e.g. from a suitable alarm system. Pay attention to the correct po-

larity.

Screw terminals “TAMPER N.C.”

This is a potential-free tamper contact. When opening the housing, the contact is interrupted so 

that a connected alarm system can trigger an alarm.
The maximum contact rating is 12 V/DC, 50 mA.

Screw terminals “ALARM”

This is a potential-free relay contact. Using the jumper “MODE P/S” (2), the function can be 

toggled between operation as NC contact (opener) and NO contact (closer).
The relay contact is triggered when the motion detector detects a heat change in the detection 

range.
The maximum contact rating is 24 V/DC, 100 mA.

c) Setting jumpers

Jumper “LED ON/OFF” (1)

Position “ON” 

 The LED is illuminated when a movement was detected in the detec-

tion range or when the housing is opened and the tamper contact is 

triggered.

Position “OFF” 

 The LED is on continuously. This can be used when when the activa-

tion process (when a heat change is detected in the detection range) 

of the motion detector should not be visible in the dark.

Position “30 MIN” 

 The LED flashes for 2 mins during the power up delay, then goes to 

walk-test mode for 30 mins for the installer to perform the walk-test; 

after that the LED turns OFF automatically. LED auto-off is preferred 

by system installers who prefer not to re-open the PIR sensor box to 

set the jumper back to the OFF position to disable the LED after the 

walk-test. 

Jumper “MODE P/S” (2)

Position “S”  

 The motion detector is activated immediately in the event of a heat 

change.

Position “P”  

 The motion detector is only activated if a second heat change is de-

tected within 10 seconds inside the detection range. This setting can 

be used, for example, when the motion detector is erroneously acti-

vated due to the existing environmental conditions.

Jumper “ALARM” (3)

Position “N.C.” 

 The screw terminals “ALARM” function as NC contact (opener). The 

contact is opened when the motion detector detect a heat change in 

the detection range.

Position “N.O.” 

 The screw terminals “ALARM” function as NO contact (closer). The 

contact is closed when the motion detector detect a heat change in 

the detection range.

d) Startup

• When you have connected all cables and 

made all settings, place the front of the hous-

ing while paying attention to its correct position 

and screw it tight. 

•  Align the motion detector to the desired detec-

tion range. 

•  Switch on the voltage/power supply.
  Then, it will take about 2 minutes until the PIR sensor have adjusted to the ambient temper-

ature of the detection area.

 

 During this time, the red LED (5) flashes if it is switched on (“ON”) via the jumper 

“LED ON/OFF” (1). 

 

 After these 2 minutes, the motion detector is ready for operation and switches the 

relay when it detects heat changes in the detection range.

Maintenance and Cleaning

The product is maintenance-free. Repair or maintenance work must be carried out by a spe-

cialist. 
You can use a clean, dry, soft cloth for cleaning. Do not press too hard on the lens of the PIR 

sensor.
Do not use aggressive, chemical or scouring cleaning agents, as this may lead to discoloura-

tion or changes in the material on the surface.

Disposal

  Electronic devices are recyclable waste and must not be disposed of in the 

household waste. At the end of its service life, dispose of the product in accordance 

with applicable regulatory guidelines. You thus fulfill your statutory obligations and 

contribute to the protection of the environment.

Technical Data

Operating voltage ...........................................12 V/DC
Current consumption ......................................approx. 15 mA
Contact rating .................................................Connection „ALARM“: max. 24 V/DC, 100 mA

........................................................................

Connection “TAMP N.C.”: max. 12 V/DC, 50 mA

Contact type ................................................... Connection “ALARM”: Relay: function can be 

toggled between NC contact (opener) and NO 

contact (closer)

........................................................................

Connection “TAMP N.C.”: Button, NC contact 

........................................................................

(opener)

Switch duration (connection “ALARM”) .......... approx. 2 - 3 seconds (when a heat change is 

detected in the detection range)

PIR detection angle ........................................85° (horizontal)
PIR range ....................................................... max. 12 m (see chapter “Function of the motion 

detector”)

Ambient conditions ......................................... Temperature -10 °C to +55 °C, air humidity max. 

90%, not condensing

Dimensions (H x W x D) .................................105 x 60 x 42 mm (without wall holder)
Weight ............................................................approx. 74 g

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights 

including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data 

processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication 

represents the technical status at the time of printing.
Copyright 2021 by Conrad Electronic SE. 

*751560_v2_0421_02_dh_m_4L

Содержание 751560

Страница 1: ...ahrloser Betrieb nicht mehr m glich ist so ist das Produkt au er Betrieb zu setzen und gegen unbeabsich tigten Betrieb zu sichern Lassen Sie das Produkt anschlie end von einem Fachmann pr fen Es ist a...

Страница 2: ...sch aus Die automatische Abschaltung der LED wird von Errichtern bevorzugt die das Sensorgeh use nicht erneut ffnen m chten um die Steckbr cke auf die Position OFF zur ckzusetzen und die LED nach dem...

Страница 3: ...ensor do not touch 7 Tamper button TAMPER 8 Screw terminals for connection Operating instructions Dual Motion Detector Item no 751560 Intended use The motion detector s integrated PIR sensor a special...

Страница 4: ...s who prefer not to re open the PIR sensor box to set the jumper back to the OFF position to disable the LED after the walk test Jumper MODE P S 2 Position S The motion detector is activated immediate...

Страница 5: ...commande 751560 Utilisation conforme Le capteur PIR un composant de capteur dual pyro sp cial int gr dans le d tecteur de mouvement r agit aux changements de temp rature dans la zone de d tection par...

Страница 6: ...alier en posi tion OFF et d sactiver le voyant apr s le test de marche Pont enfichable MODE P S 2 Position S Le d tecteur de mouvement se d clenche imm diatement en cas de variation de temp rature dan...

Страница 7: ...getoets TAMPER 8 Schroefklemmen voor aansluiting Gebruiksaanwijzing Duale bewegingsmelder Bestelnr 751560 Beoogd gebruik De in de bewegingsmelder ge ntegreerde PIR sensor een speciaal dubbel pyro sens...

Страница 8: ...utomatische led uitschakeling heeft de voorkeur van systeeminstallateurs die de sensorbox niet opnieuw wil len openen om de jumper terug in de UIT stand te zetten en de led na de doorlooptest zelf uit...

Отзывы: