28
b) Setting up a master slave chain
The effect light can be operated controlled by a DMX controller or in a master-slave chain. In that case, the integrated
controller of the master device controls the connected slave devices.
• Connect the DMX OUT port of the master device to the DMX IN port of the first slave device.
• Connect the DMX OUT port of the first slave device to the DMX IN port of the subsequent slave device.
• Proceed as described above with all remaining slave devices.
• Plug an XLR plug with a terminating resistor into the DMX OUT connection of the last slave device (as described in
section “Connection of a DMX controller”).
9. Mains connection
The mains socket to which the effect light is connected must be close to the device and easily accessible
to quickly separate the device from the mains voltage in case of an error.
Ensure that the voltage indication on the effect light matches the mains voltage of your power supply. Never
try to operate the device with any other voltage.
Do not let the mains cable come into contact with other cables.
Be careful when handling mains cables and mains connections. Mains voltage may cause potentially fatal
electric shock.
Make sure that no cables lie around openly. Install cables professionally to prevent accidents.
• Connect the mains cable low-voltage plug to the connection POWER IN at the device.
• Plug the mains plug of the mains line into a grounded socket.
• Once the device is connected to the mains socket, it takes up operation.