Renishaw UCC MMI-2 Скачать руководство пользователя страница 2

General information

© 2019 ‐ 2020 Renishaw plc. All rights reserved.

This document may not be copied or reproduced in whole or in part, or transferred to any other media or language by any means, without the

prior written permission of Renishaw.

Disclaimer

WHILE CONSIDERABLE EFFORT WAS MADE TO VERIFY THE ACCURACY OF THIS DOCUMENT AT PUBLICATION, ALL WARRANTIES,

CONDITIONS, REPRESENTATIONS AND LIABILITY, HOWSOEVER ARISING, ARE EXCLUDED TO THE EXTENT PERMITTED BY LAW.

RENISHAW RESERVES THE RIGHT TO MAKE CHANGES TO THIS DOCUMENT AND TO THE EQUIPMENT, AND/OR SOFTWARE AND THE

SPECIFICATION DESCRIBED HEREIN WITHOUT OBLIGATION TO PROVIDE NOTICE OF SUCH CHANGES.

Trade marks

RENISHAW

®

, the probe symbol and REVO

®

 are registered trade marks of Renishaw plc.

Renishaw product names, designations and the mark ‘apply innovation' are trade marks of Renishaw plc or its subsidiaries.

Other brand, product or company names are trade marks of their respective owners.

WEEE

The use of this symbol on Renishaw products and / or accompanying documentation indicates that the product should not be mixed with

general household waste upon disposal. It is the responsibility of the end user to dispose of this product at a designated collection point for

waste electrical and electronic equipment (WEEE) to enable reuse or recycling. Correct disposal of this product will help to save valuable

resources and prevent potential negative effects on the environment. For more information, please contact your local waste disposal service

or Renishaw distributor.

Warranty

Unless you and Renishaw have agreed and signed a separate written agreement, the equipment and/or software are sold subject to the

Renishaw Standard Terms and Conditions supplied with such equipment and/or software, or available on request from your local Renishaw

office.

Renishaw warrants its equipment and software for a limited period (as set out in the Standard Terms and Conditions), provided that they are

installed and used exactly as defined in associated Renishaw documentation. You should consult these Standard Terms and Conditions to find

out the full details of your warranty.

Equipment and/or software purchased by you from a third-party supplier is subject to separate terms and conditions supplied with such

equipment and/or software. You should contact your third-party supplier for details.

UCC MMI-2 installation guide

www.renishaw.com

 

 

Issued 08 2020

2

Содержание UCC MMI-2

Страница 1: ...UCC MMI 2 installation guide Documentation part number H 1000 7605 02 B UCC MMI 2 installation guide www renishaw com Issued 08 2020 1...

Страница 2: ...e upon disposal It is the responsibility of the end user to dispose of this product at a designated collection point for waste electrical and electronic equipment WEEE to enable reuse or recycling Cor...

Страница 3: ...on details Renishaw plc Registered in England and Wales Company no 1106260 Registered office New Mills Wotton under Edge Gloucestershire GL12 8JR UK Packaging To aid end user recycling and disposal th...

Страница 4: ...y cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case you will be required to correct the interfe...

Страница 5: ...UCC MMI 2 installation guide www renishaw com Issued 08 2020 5...

Страница 6: ...ce must be sited within easy reach of the operator and comply with IEC61010 and any applicable national wiring regulations for the country of installation WARNING Earthing of the UCC MMI 2 is required...

Страница 7: ...ensing for temperatures up to 40 C linearly derating to 50 at 50 C Pollution degree 2 NOTE If the UCC MMI 2 is to be used in an environment where a higher IP rating is required then the UCC MMI 2 will...

Страница 8: ...Electrical equipment of machines Part 1 General requirements BS EN 61010 1 2010 A1 2019 Safety requirements for electrical equipment for measurement control and laboratory use General requirements BS...

Страница 9: ...ches the scales positions when a touch trigger event is detected The UCC MMI 2 also supports limited 24 V machine IO signalling and can interface to a manual head if required Key Description Key Descr...

Страница 10: ...Supports manual heads Connection for the TP20 TP1 TP2 and TP6 touch trigger probes CMM machine input output including Air solenoid Air status 13 uncommitted I O 6 input and 7 output that can be custom...

Страница 11: ...irectly attached to the CMM s functional earth The grounding must be continuous between all equipment in the installation All cable connectors should be secured to the UCC MMI 2 by the connector jack...

Страница 12: ...rack system WARNING Ensure the UCC MMI 2 is disconnected from the mains supply during installation Free standing installation Four self adhesive feet are supplied with the unit for non rack mounted i...

Страница 13: ...with this kit are M5 6 mm countersink type The rack mounting kit Renishaw part number A 5518 0005 contains two brackets and four M5 6 mm screws Assemble the brackets to the UCC MMI 2 as shown below UC...

Страница 14: ...Earth bonding scheme NOTE May be protective earth where appropriate for electrical safety UCC MMI 2 installation guide www renishaw com Issued 08 2020 14...

Страница 15: ...correct operation The UCCassist 2 application included in this software release will allow the user to correctly configure the system to use the UCC MMI 2 The software can be obtained online at www re...

Страница 16: ...USB type B UCC MMI 2 power socket 6 3 mm socket Key Description Key Description 1 Scale 0 interface 15W HDD socket 5 PICS 9W D socket 2 Scale 1 interface 15W HDD socket 6 PC connection USB type B 3 S...

Страница 17: ...w NOTE If the machine scale is of a different format e g analogue single ended then this will require an external adaptor Pin no Function 1 Reserved 2 0 V scale supply 3 Error 4 Reference mark 5 B sig...

Страница 18: ...n both cases the scale supply voltage is nominally 5 V and can be adjusted to a maximum of 7 V The sense and supply signals should be connected as close to the encoder as possible see diagram below Th...

Страница 19: ...s If the error signal is not integrated into the connected encoder then the user should connect pin 3 Error to pin 7 V scale UCC MMI 2 scale limit switch interface circuit If scale limit switch signal...

Страница 20: ...ved 6 Uncommitted output 0 28 Reserved 7 Uncommitted output 1 29 Reserved 8 Uncommitted output 2 30 Reserved 9 Uncommitted output 3 31 Reserved 10 Uncommitted output 4 32 Reserved 11 Uncommitted outpu...

Страница 21: ...10 k pull up resistor to external I O 24 V is suitable for driving devices in the range 5 V to 24 V and can sink a maximum current of 200 mA If the output is not required then it should be left as an...

Страница 22: ...l should be connected to a suitable air pressure switch This input is monitored by the controller and when activated a system fatal fault is logged During the commissioning process it is possible to i...

Страница 23: ...active low 2 PICS PPOFF active low probe power off 3 0 V 4 PICS LED anode 5 Probe signal 6 Reserved 7 PICS PDAMP active low probe damping 8 PICS LEDOFF active low LED off 9 0 V Shell Screen Please ref...

Страница 24: ...rting up to full speed mode A 5 m USB cable is provided for this link as part of the UCC MMI 2 kit Other lengths may be used the maximum being 5 m which is governed by the generic specification for US...

Страница 25: ...warranted and approved for use with the provided PSU The PSU provides the UCC MMI 2 with up to 72 W at 24 Vdc The UCC MMI 2 power socket interfaces with a dc jack plug 2 5 mm inner diameter 5 5 mm out...

Страница 26: ...articularly those related to safety and safeguarding NOTE It is strongly recommended that any measuring equipment is regularly checked for accuracy An initial pass off test should be performed prior t...

Страница 27: ...e for damage and the safety of the connections Remove dust from the external surfaces with a clean dry cloth as the unit is not sealed against liquid WARNING Maintenance should only be carried out aft...

Страница 28: ...tem status is provided by two LEDs on the front panel providing assistance in diagnosing and rectifying system faults LED status key Description LED on displaying green amber or red Red flash Green fl...

Страница 29: ...st comms with software Probe LED constant green No fault Normal operation Probe seated normal operation Probe LED constant red No fault Normal operation Probe open normal operation Fatal faults Situat...

Страница 30: ...ails please visit our main website at www renishaw com contact Renishaw plc New Mills Wotton under Edge Gloucestershire GL12 8JR United Kingdom T 44 0 1453 524524 F 44 0 1453 524901 www renishaw com c...