TONiC RKLC20-S linear installation guide

13

Ti / TD  interface

Customer 
electronics

Inner shield

Outer shield

Output 

signals

0 V

5 V

Readhead

Electrical connections

IMPORTANT: The outer shield should be connected to the machine earth (Field Ground). The inner shield 
should be connected to 0 V at receiving electronics only. Care should be taken to ensure that the inner and 
outer shields are insulated from each other. If the inner and outer shields are connected together, this will 
cause a short between 0 V and earth, which could cause electrical noise issues.

NOTE: Maximum cable length between readhead and Ti / TD interface is 10 m

Single ended alarm signal termination (Ti options A, B, C, D)

Customer 

electronics

Interface

5 V

4k7

4k7

1k8

100R

100nF

E−

Extension cable  

maximum 50 m  

dependent upon  

clocked output  

option

Remote CAL operation 

(Analogue versions only)

CAL

0 V

All Ti / TD interfaces include a push button switch to enable CAL /AGC 
features. However, remote operation of the CAL /AGC is possible via  
pin 14 of analogue Ti0000 interfaces. For applications where no  
interface is used, remote operation of CAL /AGC is essential.

TD interface resolution switching

Pin 10

0 V

Connect pin 10 to 0 V to switch to lower resolution.

Analogue outputs 

V

0

 V

1

 V

2

V

0

 

V

1

 V

2

+

120R

V

p

 V

q

 P Q

R*

5 to 24 V

*Select R so maximum current does not exceed 20 mA.
 Alternatively use a suitable relay or opto-isolator.

Limit output 

(No limits on TD interfaces)

Recommended signal termination

Standard RS422A line receiver circuitry 
Capacitors recommended for improved noise immunity

120R

A B Z E

Customer 
electronics

Cable Z

0

 = 120R

A B Z E+

220 pF

220 pF

0 V

0 V

Grounding and shielding

Digital outputs

Содержание TONiC RKLC20-S

Страница 1: ...RSLM high accuracy linear encoder TONiC T103x RKLC20 S linear encoder system Installation guide M 9653 9568 01 A...

Страница 2: ...allation drawing 5 Scale application 6 End clamps 6 Reference mark selector and limit magnet installation 7 TONiC quick start guide 8 System connection 9 Readhead mounting and alignment 10 System cali...

Страница 3: ...n which case the user will be required to correct the interference at his own expense NOTE This unit was tested with shielded cables on the peripheral devices Shielded cables must be used with the uni...

Страница 4: ...ive tape is on the outside of bend 95 relative humidity non condensing to EN 60068 2 78 Humidity Storage 70 C 0 C Operating Storage and handling Readhead only Acetone CH3 COCH3 Methylated Spirits Chlo...

Страница 5: ...Recommended mounting faces Scale thickness 0 15 including adhesive P limit magnet Reference mark selector magnet Q limit magnet Yaw tol 0 4 Rideheight 2 1 0 15 Pitch tol 1 2 off mounting holes M2 5 t...

Страница 6: ...isable Push and hold during power Off On cycle Restore factory defaults Refer to readhead LED functionality chart for CAL LED indications 15 1 8 9 16 4 40 UNC 2 40 6 min 62 67 CAL AGC push button swit...

Страница 7: ...A 9653 0291 P limit A 9653 0292 START see page 6 Scale length L Measuring length ML L 40 ML L 55 with dual limits 0 5 F 0 2 100 20 A P limit magnet A 9653 0138 Dimensions as Q limit RKLC20 S scale Ref...

Страница 8: ...travel ensuring the backing paper is pulled manually from the scale and does not catch under the applicator Remove applicator carefully Apply firm finger pressure via a clean lint free cloth along th...

Страница 9: ...the scale NOTE Reference and limit magnets may creep when influenced by magnetic materials in close proximity In such cases they should be held in place using an additional fillet of epoxy glue or sim...

Страница 10: ...dhead Green interface ideally Blue Purple CALIBRATION Press and release the CAL button on the interface The CAL LED on the readhead will be single flashing Move the readhead along the scale at slow sp...

Страница 11: ...5 hex head screws 2 Taking care not to touch the pins plug the connector into the socket in the interface ensuring correct orientation as shown 3 Refit the cover plate ensuring the cable ferrule is lo...

Страница 12: ...iguration Also some configurations do not output overspeed alarm See product nomenclature for details Momentary status only while fault condition remains Alarm may result in axis position error re dat...

Страница 13: ...g the calibration routine Step 2 Reference mark phasing u Move the readhead back and forth over the selected reference mark until the CAL LED stops flashing and remains off The reference mark is now p...

Страница 14: ...shield on UHV cables Interface output digital Ti0004 to Ti20KD and TD4000 to TD0040 Interface Ti0004 Ti20KD TD4000 TD0040 Function Output type Signal Pin Pin Power 5 V 7 8 7 8 0 V 2 9 2 9 Incremental...

Страница 15: ...100R 100nF E Extension cable maximum 50 m dependent upon clocked output option Remote CAL operation Analogue versions only CAL 0 V All Ti TD interfaces include a push button switch to enable CAL AGC...

Страница 16: ...e high or Active low P Q Repeatability 0 1 mm Length of limit actuator Incremental 2 channels A and B in quadrature 90 phase shifted Reference NOTE Select standard or wide reference at time of orderin...

Страница 17: ...ly integrated to achieve EMC compliance In particular attention to shielding arrangements is essential RKLC20 S scale specifications Form H W 0 15 mm 6 mm including adhesive Pitch 20 m Accuracy at 20...

Страница 18: ...e marks of Renishaw plc in the United Kingdom and other countries apply innovation and names and designations of other Renishaw products and technologies are trade marks of Renishaw plc or its subsidi...

Отзывы: