4.5
Trig
g
er Logic
Enhanced trigger filter setting and auto-reset facility
Auto reset off
Trigger filter
on 8 ms
Auto reset off
Trigger filter
on 16 ms
Auto reset on
Trigger filter
on 8 ms
Auto reset on
Trigger filter
on 16 ms
Auto reset off
Trigger filter
off
Stop triggering here, unless “
Multiple probe
mode
” is required, in which case deflect the
stylus for more than 4 seconds.
If no changes are made in “
Multiple probe mode
”, deflecting the stylus for more
than 4 seconds will return the probe settings to
“Switch-on mode”
menu. If
“
Multiple probe mode
” is selected, proceed to “
Acquisition mode
” to repartner
one probe with the RMI or RMI-Q.
Multiple probe mode
(omitted for
“Radio on”
)
(see
“Multiple probe mode settings”
to view all 16 choices)
Mode off
Mode on
Machine 1
Machine 2
Machine 16
Acquisition mode
Acquisition mode off
Acquisition mode on
Acquisition mode
Acquisition mode off
Acquisition mode on
New settings
complete
Return to
“Switch-on method”
NOTES:
If using “
Multiple probe mode
”, refer to the
RMI radio machine interface
installation guide (Renishaw
part no. H-4113-8554) or the
RMI-Q radio machine interface
installation guide (Renishaw part no.
H-5687-8504).
Further probes used require the same “
Multiple probe mode
” setting, but do not need to be partnered
with the RMI or RMI-Q.
To partner an RMP600 with an RMI, see page 4.6, “RMP600 – RMI partnership”, or with an RMI-Q
see page 4.7, “RMP600 – RMI-Q partnership”, for further information. Once acquisition has been
successful, the RMP600 will revert to “
Acquisition
mode off
”.