7.1
Symptom
Cause
Action
The probe fails to
power up (no LEDs
illuminated or fails
to indicate current
probe settings).
Dead batteries.
Change batteries.
Unsuitable batteries.
Fit suitable batteries.
Batteries inserted incorrectly.
Check battery insertion/polarity.
Batteries removed for too short a time
and probe has not reset.
Remove batteries for a minimum
of 5 seconds.
Poor connection between battery
cassette mating surfaces and
contacts.
Remove any dirt and clean the
contacts before reassembly.
The probe fails to
switch on.
Dead batteries.
Change batteries.
Batteries inserted incorrectly.
Check battery insertion/polarity.
Probe out of range.
Check position of RMI-Q or
RMI-QE, see operating envelope.
No RMI-Q or RMI-QE “start/stop”
signal (
“radio on mode”
only).
Check RMI-Q or RMI-QE for green
start LED.
Incorrect spin speed (
“spin on
mode”
only).
Check spin speed and duration.
Malfunctioning shank switch (
“shank
switch-mode”
only).
Check switch operation.
Incorrect
“switch on”
method
configured.
Check configuration and alter as
required.
Incorrect
“multiple probe mode”
setting configured (RMI-Q only).
Check configuration and alter as
required.
RMP60 in
“hibernation mode”
(RMI-Q and
“radio on”
method only).
Ensure probe is in range and wait
up to 30 seconds, then resend
switch-on signal.
Check position of RMI-Q, see
operating envelope.
Spin on is within 1 second of spin off.
Check for 1 second dwell following
spin off.
Fault-finding
see Section 6,“Fault-finding”
Содержание RMP60
Страница 1: ...RMP60 QE radio machine probe Installation guide H 6587 8520 01 A...
Страница 6: ...RMP60 installation guide iv Contents This page is intentionally left blank...
Страница 12: ...RMP60 installation guide 1 6 Before you begin This page is intentionally left blank...
Страница 24: ...RMP60 installation guide 2 12 RMP60 basics This page is intentionally left blank...
Страница 64: ...RMP60 installation guide 7 6 Fault finding This page is intentionally left blank...
Страница 67: ......