2.7

RMP60 basics

Multiple probe mode 

(only applicable when RMP60 is used with RMI-Q)

The RMP60 can be configured, using Trigger Logic, to allow multiple radio probes in “spin on/spin off” 
or “shank on/shank off” to be used with a single RMI-Q.

Up to four RMP60s can be used with a single RMI-Q or in 

“radio on / radio off mode”

. For further 

details of this functionality, refer to the 

RMI-Q radio machine interface 

installation guide (Renishaw part 

no. H-5687-8504).

NOTES:

“Multiple probe mode”

 will not appear when the 

“radio on”

 option has been selected.

RMP60 probes which are set to 

“multiple probe mode on”

 can coexist alongside any number of 

RMP60 probes set to 

“multiple probe mode off”

.

To allow multiple radio probes to work in close proximity, and with a single RMI-Q, 16 choices of 

“mode on”

 colours are available, each representing a different machine tool installation; for more 

information, see page 4.3

“Multiple probe mode settings”

.

All probes operating with a single RMI-Q must be set to the same 

“mode on”

 colour choice; any 

multiple probes located on adjacent machines must all be set to an alternative 

“mode on”

 colour 

choice.

NOTE:

 Each probe per 

“mode on”

 colour choice must be partnered with the RMI-Q

. By configuring 

multiple probes to a single 

“mode on”

 colour choice, all probes using this 

“mode on”

 colour choice 

will have the same identity. 

The probe is partnered after selecting the 

“multiple probe mode” 

setting and choosing the 

“mode 

on”

 option; for more information, see page 4.10, 

“Changing the probe settings”

.

There is no limit to the number of probes that can be used with a single RMI-Q so long as they all have 
the same 

“mode on”

 colour choice. All RMP60 probes are factory set to 

“mode off”

.

The addition of any further probe(s), or replacements, into a multi-probe installation can be achieved 
through the reconfiguration of the probe to the same 

“mode on”

 colour choice.

NOTE:

 

“Multiple probe mode”

 does not exist when an RMP60 (model RMP60QE) is used with an 

RMI-QE.

Содержание RMP60

Страница 1: ...RMP60 QE radio machine probe Installation guide H 6587 8520 01 A...

Страница 2: ...ansferred to any other media or language by any means without the prior written permission of Renishaw plc Renishaw plc Registered in England and Wales Company no 1106260 Registered office New Mills W...

Страница 3: ...tware licensing agreement 1 3 Intended use 1 4 Safety 1 4 RMP60 basics 2 1 Introduction 2 1 Getting started 2 2 System interface 2 2 Probe configuration 2 3 Opti Logic 2 3 Trigger Logic 2 3 Probe mode...

Страница 4: ...3 9 Why calibrate a probe 3 9 Calibrating in a bored hole or on a turned diameter 3 9 Calibrating in a ring gauge or on a datum sphere 3 10 Calibrating the probe length 3 10 Probe configuration 4 1 C...

Страница 5: ...nce 5 1 Maintenance 5 1 Cleaning the probe 5 1 Changing the batteries 5 2 Diaphragm replacement 5 4 RMP60M system 6 1 RMP60M system 6 1 RMP60M dimensions 6 2 RMP60M screw torque values 6 2 Fault findi...

Страница 6: ...RMP60 installation guide iv Contents This page is intentionally left blank...

Страница 7: ...mark of Apple Inc registered in the U S and other countries Other brand product or company names are trade marks of their respective owners Warranty Unless you and Renishaw have agreed and signed a se...

Страница 8: ...RMP60M and other similar Renishaw products are the subject of one or more of the following patents and or patent applications CN 100416216 CN 100466003 CN 101476859 CN 101482402 EP 1425550 EP 1457786...

Страница 9: ...e Copyright 2009 2015 ARM LIMITED All rights reserved Redistribution and use in source and binary forms with or without modification are permitted provided that the following conditions are met 1 Redi...

Страница 10: ...the batteries in a fire Avoid forced discharge of the batteries Do not short circuit the batteries Do not disassemble apply excessive pressure pierce deform or subject the batteries to impact Do not...

Страница 11: ...idelines are adhered to in order for the product to function in accordance with these regulations any interface MUST be installed in a position away from any potential sources of electrical noise for...

Страница 12: ...RMP60 installation guide 1 6 Before you begin This page is intentionally left blank...

Страница 13: ...avel The RMP60 complies with worldwide standards and operates in the 2 4 GHz band It delivers interference free transmission through the use of hybrid FHSS frequency hopping spread spectrum technology...

Страница 14: ...ng a single flash of red green blue indicates that the probe is operating in RMI Q mode An LED check displaying double flashes of red green blue indicates that the probe is operating in RMI QE mode Sy...

Страница 15: ...user to view and select all available mode settings in order to customise a probe to suit a specific application Trigger Logic is activated by battery insertion and uses a sequence of stylus deflectio...

Страница 16: ...60 basics Configurable settings Switch on switch off methods The following switch on switch off options are user configurable Radio on Radio off Radio on Timer off Spin on Spin off Spin on Timer off S...

Страница 17: ...reseat 1 second maximum see notes below Shank switch on Shank switch off 1 second maximum NOTES In radio on mode the switch on time is user selectable fast or standard when using RMI Q or RMI QE selec...

Страница 18: ...ded time delay The trigger filter is factory set to Level 1 OFF Hibernation mode Only applicable to radio on mode when RMP60 is used with a RMI Q When the RMP60 is in standby and the RMI Q is powered...

Страница 19: ...ation see page 4 3 Multiple probe mode settings All probes operating with a single RMI Q must be set to the same mode on colour choice any multiple probes located on adjacent machines must all be set...

Страница 20: ...ion see page 4 2 Reviewing the probe settings Display of Hibernation mode or Multiple probe mode menus also indicates that the RMP60 is in RMI Q mode NOTES Prior to partnering for the first time the R...

Страница 21: ...travel limits Stylus length X Y Z 50 1 97 21 0 82 11 0 43 100 3 94 37 1 45 11 0 43 A range of probe ready shanks are available from Renishaw 50 1 97 19 0 75 Battery cassette Shank switch optional 18 1...

Страница 22: ...igger force 2 3 Factory setting XY low force XY high force Z 0 75 N 76 gf 2 70 ozf 1 40 N 143 gf 5 04 ozf 5 30 N 540 gf 19 06 ozf Maximum setting XY low force XY high force Z 2 00 N 204 gf 7 19 ozf 3...

Страница 23: ...ife Radio on Spin on Shank on 1 s turn on 0 5 s turn on Standby life 101 months 65 months 79 months 169 months Light usage 1 89 months 59 months 71 months 135 months Heavy usage 5 59 months 45 months...

Страница 24: ...RMP60 installation guide 2 12 RMP60 basics This page is intentionally left blank...

Страница 25: ...ws easy installation inside the machine Coolant and swarf residue accumulating on the RMP60 and RMI Q or RMI QE may have a detrimental effect on transmission performance Wipe clean as often as is nece...

Страница 26: ...is unpowered or the RMP60 is out of range When in hibernation mode the RMP60 checks for a powered RMI Q every 30 seconds If found the RMP60 goes from hibernation mode to standby mode ready for radio o...

Страница 27: ...3 3 System installation Preparing the RMP60 for use Fitting the stylus 1 2 M 5000 3707 1 8 Nm 2 2 Nm 1 3 lbf ft 1 6 lbf ft...

Страница 28: ...mic or carbon fibre styli Fitting a stylus with weak link onto RMP60 In the event of excessive stylus overtravel the weak link is designed to break thereby protecting the probe from damage Take care t...

Страница 29: ...e the product is clean and dry before inserting batteries Do not allow coolant or debris to enter the battery compartment When inserting batteries check that the battery polarity is correct After inse...

Страница 30: ...2 Nm 3 Nm 1 5 lbf ft 2 2 lbf ft 2 NOTE In instances where the RMP60 is to be used with a shank switch it will be necessary to remove the plug from the rear of the probe using pliers This should then b...

Страница 31: ...robe relative to the shank as damage to the bobbin A 4038 0303 can occur where fitted If a probe and shank assembly is dropped it must be rechecked for correct on centre adjustment Do not hit or tap t...

Страница 32: ...ing a part To adjust the trigger force turn the adjusting screw anticlockwise to reduce the force more sensitive or clockwise to increase the force less sensitive A stop helps to prevent damage which...

Страница 33: ...ompensate for mechanical changes of your machine tool If repeatability of relocation of the probe shank is poor In this case the probe may need to be recalibrated each time it is selected It is good p...

Страница 34: ...are also used to give true positions of single surface features NOTE The stored radius values are based on the true electronic trigger points These values are different from the physical sizes Calibra...

Страница 35: ...through the process of setting up and configuring a Renishaw machine tool probing system Using Opti Logic Opti Logic is the process of transmitting and receiving data from the app to a Renishaw machin...

Страница 36: ...k off or Short timeout 12 s or Medium timeout 33 s or Long timeout 134 s Probe in standby mode Battery status Battery good or Battery low Multiple probe mode RMI Q only omitted for Radio on see Multip...

Страница 37: ...han 4 seconds to cycle to the next setting Multiple probe mode Mode off Mode on or Machine 1 or Machine 2 or Machine 3 or Machine 4 Machine 5 or Machine 6 or Machine 7 or Machine 8 Machine 9 or Machin...

Страница 38: ...ut 12 s Medium timeout 33 s Long timeout 134 s Trigger filter Level 1 Level 2 Level 3 Hibernation mode setting RMI Q only On 30 s On 5 s Off Multiple probe mode RMI Q only Off factory set On machine n...

Страница 39: ...he RMI Q or RMI QE must be turned on If an RMI Q is turned on the RMP60 will continue to display the sequence of cyan flashes If an RMI QE is turned on the RMP60 display sequence will now incorporate...

Страница 40: ...status will flash red to acknowledge this At this point turn on the RMI Q or RMI QE Partnering mode Off RMI QE found Active 20 seconds probe in standby 120 seconds probe in standby After 8 seconds RMI...

Страница 41: ...red In configuration mode configure the probe settings as required until you reach the Partnering mode menu which defaults to Partnering mode off Deflect the stylus to select Partnering mode active En...

Страница 42: ...batteries Partnering can take place anywhere within the operating envelope An RMP60 that is partnered with the RMI QE but then used with another system will need to be repartnered before being used ag...

Страница 43: ...ready for use NOTE Refer to the RMI QE radio machine interface installation guide Renishaw part no H 6551 8520 when partnering up to four radio probes SYSTEM STATUS LED New radio probe partnered or S...

Страница 44: ...already been installed remove them for 5 seconds and then refit them Following the LED check immediately deflect the stylus and hold it deflected until eight red flashes have been observed if the bat...

Страница 45: ...rn the probe settings to beginning of the Trigger Logic menu If Multiple probe mode is selected proceed to Partnering mode to repartner one probe with the RMI Q Multiple probe mode omitted for Radio o...

Страница 46: ...rther probes used require the same Multiple probe mode setting but do not need to be partnered with the RMI Q To partner an RMP60 with an RMI Q see page 4 7 RMP60 RMI Q partnership for further informa...

Страница 47: ...n installed remove them for 5 seconds and then refit them Following the LED check immediately deflect the stylus and hold it deflected until eight red flashes have been observed if the battery power i...

Страница 48: ...tion New settings complete probe in standby NOTE To partner an RMP60 with an RMI QE see page 4 5 Probe partnering function for further information on how to reach Partnering mode Return to Switch on m...

Страница 49: ...efit them 2 Following the LED check immediately deflect the stylus and hold it deflected until eight red flashes have been observed if the battery power is low each red flash will be followed by a blu...

Страница 50: ...in until the eight yellow flash sequence has ended System status LED Deflect the stylus for 20 seconds until the status LEDs start to flash yellow eight times 4 Previous settings have been cleared The...

Страница 51: ...rigger Logic menu and will display Switch on method Configure probe settings as required using Trigger Logic 6 NOTE The RMP60 will continue to be partnered with either the RMI Q or RMI QE following th...

Страница 52: ...sequence see page 4 2 Reviewing the probe settings for further information 4 Again the batteries discharge and the probe ceases to function 5 Again the batteries recover sufficiently to provide the pr...

Страница 53: ...Renishaw Service Centre Equipment requiring repair overhaul or attention under warranty should be returned to your supplier Cleaning the probe Wipe the window of the probe with a clean cloth to remov...

Страница 54: ...atteries do not allow coolant or debris to enter the battery compartment When changing batteries check that the battery polarity is correct Take care to avoid damaging the battery cassette gasket Only...

Страница 55: ...aces are clean and free from dirt before reassembly If dead batteries are inadvertently inserted the LEDs will remain a constant red 3 Battery types Alkaline 2 Lithium thionyl chloride 2 Nickel Cadmiu...

Страница 56: ...Undo the three M3 front cover screws and remove the front cover 3 Inspect the outer diaphragm for damage 4 To remove the outer diaphragm grip by the outer edge and pull off Inner diaphragm inspection...

Страница 57: ...0 by fitting selected adaptors and extensions as shown below See Section 8 Parts list RMP60M module RMP60M LP2 adaptor M4 stylus RMP60M probe module M4 stylus LP2 probe MA4 90 adaptor LPE3 extension b...

Страница 58: ...7 87 67 25 2 65 67 25 2 65 50 100 150 1 97 3 94 5 91 12 50 0 49 40 75 1 60 25 0 98 50 50 1 99 63 2 48 RMP60M screw torque values Dimensions mm in 10 Nm to 12 Nm 7 37 lbf ft to 8 85 lbf ft 2 6 Nm 1 92...

Страница 59: ...ity Probe out of range Check position of RMI Q or RMI QE see operating envelope No RMI Q or RMI QE start stop signal radio on mode only Check RMI Q or RMI QE for green start LED Incorrect spin speed s...

Страница 60: ...Check that part is correctly positioned and that stylus has not broken Stylus not given sufficient time to settle from a rapid deceleration Add a short dwell before the probing move length of dwell w...

Страница 61: ...tware Calibration and probing speeds not the same Review probing software Calibration feature has moved Correct the position Measurement occurs as stylus leaves surface Review probing software Measure...

Страница 62: ...e not switched on or probe timed out Change setting Review turn off method Probe out of range Check position of RMI Q or RMI QE see operating envelope Dead batteries Change batteries RMP60 and RMI Q o...

Страница 63: ...Use shorter timeout setting or use different switch off method Malfunctioning shank switch shank switch mode only Check switch operation Incorrect spin speed spin switch on only Check spin speed Level...

Страница 64: ...RMP60 installation guide 7 6 Fault finding This page is intentionally left blank...

Страница 65: ...Battery gasket A 4038 0301 Battery cap gasket kit Diaphragm kit A 4038 0302 RMP60 diaphragm kit Bobbin kit A 4038 0303 Bobbin for shank switch supplied with shank RMI Q A 5687 0049 RMI Q side exit wit...

Страница 66: ...w com RMP60 QE QSG H 6587 8500 Quick start guide for rapid set up of the RMP60 QE probe RMI Q QSG H 5687 8500 Quick start guide for rapid set up of the RMI Q RMI Q IG H 5687 8504 Installation guide fo...

Страница 67: ......

Страница 68: ...Edge Gloucestershire GL12 8JR United Kingdom T 44 0 1453 524524 F 44 0 1453 524901 E uk renishaw com www renishaw com For worldwide contact details visit www renishaw com contact 2022 Renishaw plc Iss...

Отзывы: