Renishaw RLI20-P Скачать руководство пользователя страница 2

© 2012-2015 Renishaw plc. All rights reserved. 

This document may not be copied or reproduced in whole or 
in part, or transferred to any other media or language, by any 
means, without the prior written permission of Renishaw.

The publication of material within this document does not imply 
freedom from the patent rights of Renishaw plc.

Disclaimer

RENISHAW HAS MADE CONSIDERABLE EFFORTS 
TO ENSURE THE CONTENT OF THIS DOCUMENT IS 
CORRECT AT THE DATE OF PUBLICATION BUT MAKES NO 
WARRANTIES OR REPRESENTATIONS REGARDING THE 
CONTENT. RENISHAW EXCLUDES LIABILITY, HOWSOEVER 
ARISING, FOR ANY INACCURACIES IN THIS DOCUMENT.

Trademarks

RENISHAW

 and the probe symbol used in the RENISHAW 

logo are registered trade marks of Renishaw plc in the United 
Kingdom and other countries. 

apply innovation

 and names and 

designations of other Renishaw products and technologies are 
trade marks of Renishaw plc or its subsidiaries.

Renishaw part no:   M-9926-0005-02-B
Issued:   09 2015

All other brand names and product names used in this 
document are trade names, trade marks, or registered trade 
marks of their respective owners.

Care of equipment

The RLI20 laser interface contains precision electronic 
components. Avoid exposure to moisture. Remove power before 
connecting, disconnecting or handling.

Changes to Renishaw products

Renishaw plc reserves the right to improve, change or modify 
its products and documentation without incurring any obligation 
to make changes to Renishaw equipment previously sold or 
distributed.

Warranty

Renishaw plc warrants its equipment provided that it is installed 
exactly as defined in associated Renishaw documentation. 

Содержание RLI20-P

Страница 1: ...RLI20 Renishaw laser interface RLI20 P laser interface Panasonic User s guide M 9926 0005 02 B...

Страница 2: ...ishaw plc in the United Kingdom and other countries apply innovation and names and designations of other Renishaw products and technologies are trade marks of Renishaw plc or its subsidiaries Renishaw...

Страница 3: ...ser is made aware of any hazards involved in the operation of their machine including those mentioned in Renishaw product documentation and to ensure that adequate guards and safety interlocks are pro...

Страница 4: ...ser will be required to correct the interference at his own expense The user is cautioned that any changes or modifications not expressly approved by Renishaw plc or authorised representative could vo...

Страница 5: ...nalogue quadrature interface 3 2 2 Serial interface 5 2 3 Error output 6 2 4 Power 6 2 5 Mechanical installation 7 3 Configuration 8 3 1 RLE set up dip switches 8 3 2 Position 9 3 3 Error output 10 3...

Страница 6: ...em into a position reading which is available over a serial bus The RLI20 P is specifically programmed to be compatible with Panasonic motor controllers 1 1 Part numbers The following saleable part nu...

Страница 7: ...direction to that expected If a voltage exceeding 7 V is applied on any of the signals damage to the unit can occur WARNING Care should be taken to ensure that individual signal wires do not short It...

Страница 8: ...The connector on the RLI20 is a 15 way female D type Figure 1 shows the mating D type connector Table 2 Analogue quadrature input 15 way D type male Pin number Function 1 0 V 2 3 Error 4 Ref Mark 5 Si...

Страница 9: ...20 is a 9 way male D type the mating connector is shown in Figure 2 Pinouts are show in Table 3 5 V power from the controller is needed to detect when the controller is switched on or power cycled Tab...

Страница 10: ...sis The 24 V power supply should be single fault tolerant certified to EN IEC 60950 1 Figure 4 4 way female M16 Binder connector 2 3 Error output The RLI20 outputs on RS422 compatible error signal Cab...

Страница 11: ...fore needs to be protected from harsh environmental conditions For connector cable clearance purposes allow 100 mm 4 in from the front face of the RLI20 Note Using the fixings supplied with the unit M...

Страница 12: ...6 and 7 only affect the direction of the digital quadrature from the RLE and not the analogue quadrature Note The RLE will flag an error when the measurement velocity reaches a level at which the requ...

Страница 13: ...sb for RRI Axis 1 is scaled relative to RLE Axis 1 wavelength at NTP of 632 818270 nm Axis 2 is scaled relative to RLE Axis 2 wavelength at NTP of 632 819719 nm NTP is defined as 101 325Pa 20 C 50 RH...

Страница 14: ...n error on either channel or a hardware error WARNING The error output is not a fail safe method and therefore additional safety precautions must be taken in safety critical closed loop applications T...

Страница 15: ...50 mm s and 1 m s PMI 100 mm s and 2 m s RRI 2 nm 4 nm Panasonic interface is limited to 400 mm sec Plane mirror interferometer Retroreflector interferometer Dimensions Length 350 mm 13 8 in Width 42...

Страница 16: ...l limit switches which when tripped will stop axis motion before damage occurs soft limits alone are insufficient 3 Motor torque monitoring If the motor torque exceeds an expected limit the axis of mo...

Страница 17: ...internal errors and errors in the encoder system that may cause invalid position feedback signals and signals a fault by asserting an error line output In the case of closed loop motion systems for s...

Страница 18: ...under Edge Gloucestershire GL12 8JR United Kingdom T 44 0 1453 524524 F 44 0 1453 524901 E uk renishaw com www renishaw com For worldwide contact details please visit our main web site at www renisha...

Отзывы: