Renishaw RGH41 Скачать руководство пользователя страница 3

RGH41 RGS40 installation guide

1

Product compliance

C

Renishaw plc declares that RGH41 complies with the applicable standards and regulations.  
A copy of the EC Declaration of Conformity is available on request.

FCC compliance

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:  
(1) This device may not cause harmful interference, and (2) this device must accept any interference  
received, including interference that may cause undesired operation.
The user is cautioned that any changes or modifications not expressly approved by Renishaw plc or 
authorised representative could void the user’s authority to operate the equipment. 
This equipment has been tested and found to comply with the limits for a Class A digital device,  
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection  
against harmful interference when the equipment is operated in a commercial environment.  
This equipment generates, uses, and can radiate radio frequency energy and, if not installed  
and used in accordance with the instruction manual, may cause harmful interference to radio 
communications. Operation of this equipment in a residential area is likely to cause harmful  
interference in which case the user will be required to correct the interference at his own expense.

NOTE:

 This unit was tested with shielded cables on the peripheral devices. Shielded cables must be  

used with the unit to ensure compliance.

RoHS compliance

Compliant with EC directive 2011/65/EU (RoHS)

Patents

Features of Renishaw’s encoder systems and similar products are the subjects of the following  
patents and patent applications:
EP 1147377      JP 4571768      US 6588333 

Further information

Further information relating to the RGH41 encoder range can be found in the RGH41

 

system  

Data sheet (L-9517-9713). This can be downloaded from our website www.renishaw.com/encoder  
and is also available from your local representative. This document may not be copied or reproduced  
in whole or in part, or transferred to any other media or language, by any means without the written  
prior permission of Renishaw. The publication of material within this document does not imply freedom  
from the patent rights of Renishaw plc. 

Disclaimer

RENISHAW HAS MADE CONSIDERABLE EFFORTS TO ENSURE THE CONTENT OF THIS 
DOCUMENT IS CORRECT AT THE DATE OF PUBLICATION BUT MAKES NO WARRANTIES  
OR REPRESENTATIONS REGARDING THE CONTENT. RENISHAW EXCLUDES LIABILITY, 
HOWSOEVER ARISING, FOR ANY INACCURACIES IN THIS DOCUMENT.

The use of this symbol on Renishaw products and/or accompanying documentation indicates that the product 
should not be mixed with general household waste upon disposal.  It is the responsibility of the end user to 
dispose of this product at a designated collection point for waste electrical and electronic equipment (WEEE) 
to enable reuse or recycling. Correct disposal of this product will help to save valuable resources and prevent 
potential negative effects on the environment. For more information, please contact your local waste disposal 
service or Renishaw distributor.

The packaging of our products contains the following materials and can be recycled.

Packaging Component

Material

ISO 11469

Recycling Guidance

Outer box

Cardboard

Not applicable

Recyclable

Polypropylene

PP

Recyclable

Inserts

Low Density Polyethylene Foam

LDPE

Recyclable

Cardboard

Not applicable

Recyclable

Bags

High Density Polyethylene Bag

HDPE

Recyclable

Metalised Polyethylene

PE

Recyclable

Содержание RGH41

Страница 1: ...Installation guide M 9537 9016 01 A RGH41 RGS40 linear encoder system...

Страница 2: ...rawing 4 Scale application 5 End clamps 6 Reference mark and limit switch installation 6 Readhead mounting and alignment 7 Reference mark set up 7 Limit switch 7 Output signals 8 Speed 9 Electrical co...

Страница 3: ...and patent applications EP 1147377 JP 4571768 US 6588333 Further information Further information relating to the RGH41 encoder range can be found in the RGH41 system Data sheet L 9517 9713 This can be...

Страница 4: ...Humidity Storage and handling Methylated Spirits Acetone CH3COCH3 Chlorinated Solvents CH3 CH2 5CH3 CH3CHOHCH3 N heptane Propan 2 ol Minimum bend radius RGS40 100 mm NOTE Ensure self adhesive tape is...

Страница 5: ...14 6 12 5 0 5 44 38 3 Pitch tol 1 0 8 2 5 2 2 4 5 0 2 18 12 6 3 Roll tol 1 0 13 8 6 3 27 13 9 Set up LED 3 6 11 6 14 5 A 2 mounting holes M3 x 7 5 deep Forward direction of readhead relative to scale...

Страница 6: ...e to the axis of motion readhead rideheight variation must be within 0 05 mm Overall length ML 70 Scale length ML 40 Measuring length ML Readhead optical centreline Reference mark sensor position insi...

Страница 7: ...ator up to the START point as shown Ensure backing tape is routed under the splitter screw 7 Apply finger pressure to the scale at the START point using a clean lint free cloth to ensure scale end adh...

Страница 8: ...t switch sensor position P limit switch sensor position End clamp If in doubt refer to the RGH41 data sheet to see if single or dual limit switch capability has been specified on the readhead you have...

Страница 9: ...nal repeatability the reference mark requires phasing with the scale in the direction of normal datuming operation A reference pulse is output in both directions but repeatability is guaranteed only i...

Страница 10: ...V White 12 10 10 B White link 13 11 11 N Incremental signals V1 Red 9 5 5 F Blue 1 6 6 R V2 Yellow 10 8 8 D Green 2 1 1 G Reference mark V0 Violet 3 3 3 K Grey 11 4 4 O Limit switch Vq Pink 8 N C N C...

Страница 11: ...for alarm function E RGH41 RGS40 installation guide 9 x 4 safety factor Encoder velocity m s Resolution m Function Signal Colour 15 way D type plug D 16 way in line connector X Power 5 V Brown 7 A Br...

Страница 12: ...stomer electronics IMPORTANT The outer shield should be connected to the machine earth Field Ground The inner shield should be connected to 0 V at receiving electronics only Care should be taken to en...

Страница 13: ...gnal level X is nominal 5 V voltage at X 5 nom 50 70 100 0 0 signal level Signal period P Resolution S A B Z Synchronised pulse Z duration as resolution S Repeatability of position uni directional mai...

Страница 14: ...120 C Minimum installation 10 C Storage 20 C to 70 C Humidity 95 relative humidity non condensing to EN 60068 2 78 General specifications Power supply 5 V 5 RGH41A 140 mA RGH41B 120 mA RGH41T D G X 95...

Страница 15: ...our main website at www renishaw com contact M 9537 9016 01 RENISHAW and the probe symbol used in the RENISHAW logo are registered trade marks of Renishaw plc in the United Kingdom and other countrie...

Отзывы: