Renishaw RCH24H30D30A Скачать руководство пользователя страница 8

Readhead part numbers

A

RGH25U 15

J

00

Datum

A - Standard reference sensor 
B - Limit switch sensor 

C - Vacuum reference sensor 
D - Vacuum Limit switch sensor

Readhead series

15 - 1.5 m 
30 - 3 m 
50 - 5 m

 

Termination

J  - 15 pin D type plug for RGB25 interface (non-vacuum only) 
M - 15 pin D type plug for RGB25 interface (vacuum only)

Cable length

Options

00 - Standard head 
01 - Vacuum head and cable

Options

00 - Standard.(RGB25B, C, D, X, and Z only) 
61 - 20 MHz customer clock (RGB25H and Y only) 
62 - 10 MHz customer clock (RGB25H and Y only) 
63 - 5 MHz customer clock (RGB25H and Y only)

RGB25

H

R

61

Type of datum sensor

R - Standard reference sensor 
L - Limit switch sensor

Interface series

Alarm

00 - E+/E- alarm for signal amplitude <15% (RGB25D, X and Z only)
     - E+/E- alarm for signal amplitude >150%; overspeed alarm;  
       3 state alarm for signal amplitude <15% (RGB25H and Y only) 
     - No alarm (RGB25B and C only)
01 - 3 state alarm for signal amplitude <15% (RGB25D, X and Z only)

00

Output

Analogue  B - 1 Vpp 
 

C - 12 µA 

Digital  D - 5 µm 
 

X - 1 µm 

 

Z - 0.5 µm 

 

Y - 0.1 µm 

 

H - 50 nm

Interface part numbers for use with RGH25U

NOTE:  Not all combinations are valid. Check valid options online at www.renishaw.com/epc

Readhead part numbers

A

Options

00 - Standard (RGH24B, C, D, X and Z only) 
01 - JST connector (RGH24D, X and Z only) 
30 - 12 MHz customer clock (RGH24H, I, O and Y only) 
31 - 8 MHz customer clock (RGH24H, I, O and Y only) 
32 - 6 MHz customer clock (RGH24W only) 
33 - 4 MHz customer clock (RGH24H, I, O, W and Y only) 
35 - 12 MHz customer clock (RGH24H, I, O and Y JST connector version only) 
36 - 8 MHz customer clock (RGH24H, I, O and Y JST connector version only) 
37 - 6 MHz customer clock (RGH24W JST connector version only) 
38 - 4 MHz customer clock (RGH24H, I, O, W and Y JST connector version only)

RGH24 X

30

A

00

Datum

A - Standard reference sensor 
B - Limit switch sensor (RGH24D, H, I, O, W, X, Y and Z only)

Readhead series

Cable length

00 - no cable (JST connector only) 
 15  - 1.5 m (all except JST connector) 
30 - 3 m (all except JST connector) 
50 - 5 m (all except JST connector)

Termination

A - 9 pin D type plug 
C - 9 pin circular plug (RGH24C only) 
D - 15 pin D type plug (RGH24D, H, I, O, W, X, Y and Z only) 
F - unterminated cable 
L - 15 pin D type plug (RGH24B only) 
Z - JST connector (RGH24D, H, I, O, W, X, Y, and Z only)

Output

Analogue  B - 1 Vpp 
 

C - 12 µA

Digital 

D - 5 µm 

 

X - 1 µm 

 

Z - 0.5 µm 

 

 W  - 0.2 µm 

 

Y - 0.1 µm 

 

H - 50 nm 

 

 I  - 20 nm 

 

O - 10 nm

NOTE:  Not all combinations are valid. Check valid options online at www.renishaw.com/epc

Содержание RCH24H30D30A

Страница 1: ...RGH24 25U series readhead Installation guide M 9541 0084 04 C...

Страница 2: ...r M 9517 2855 These can be downloaded from our website www renishaw com encoder and are also available from your local representative This document may not be copied or reproduced in whole or in part...

Страница 3: ...mark sensor limit switch sensor position Optical centreline A 9541 0037 Reference mark actuator 4 8 2 Mounting holes M3 x 0 5 through Set up LED 5 4 3 17 JST connector version 12 8 5 5 Arrow indicates...

Страница 4: ...ashes orange or goes blank the reference mark adjuster screw should be turned anti clockwise by 1 8 turn and the procedure repeated until a red flash is obtained RGH24 Red Orange Blank LED flash durin...

Страница 5: ...ued RGH25 RGB25 Red Orange Blank LED flash during reference mark traverse only turn 1 8 RGB25 input all models Function Power Incremental signals Reference mark Not connected Sin monitor Cos monitor S...

Страница 6: ...forced open circuit for 20 ms when signal too low for reliable operation For RGH24W Y H I O incremental channels forced open circuit for 10 ms when signal too low or speed too high for reliable operat...

Страница 7: ...dheads have been designed to the relevant EMC standards but must be correctly integrated to achieve EMC compliance In particular attention to shielding arrangements is critical Renishaw recommends the...

Страница 8: ...Check valid options online at www renishaw com epc Readhead part numbers A Options 00 Standard RGH24B C D X and Z only 01 JST connector RGH24D X and Z only 30 12 MHz customer clock RGH24H I O and Y o...

Страница 9: ...de contact details please visit our main website at www renishaw com contact RENISHAW and the probe emblem used in the RENISHAW logo are registered trademarks of Renishaw plc in the UK and other count...

Отзывы: