Renishaw RCH24H30D30A Скачать руководство пользователя страница 5

RGB25 Installation drawing

Dimensions in mm

127 

Set 

up 

LED

Input

 

15 

w

ay 

type

 

soc

ket

114

142

100

20

33.3

16.2

41

12

Output

 

15 

w

ay 

type

 

plug

M

ax

. s

cr

ew

 s

iz

M

4

O

pt

io

na

l m

ou

nt

in

br

ac

ke

ts 

 

(A

-9

53

9-

20

18

)

N

O

T

E

: 

R

em

ov

w

as

he

rs 

w

he

in

st

al

lin

br

ac

ke

ts

19.2

0.35 

Nm 

 

torque

Phasing procedure continued
RGH25 + RGB25

Red  Orange  Blank

LED flash during reference 

mark traverse only

/

turn

1

 

8

RGB25 input (all models)

Function

Power 

Incremental  
signals 

Reference mark

Not connected

Sin monitor

Cos monitor

Shield

5 V

0 V

V

mid

A phase

B phase

C phase

HALL

-

-

-

Signal

RGH25 core 

wire colour

Red

White

Brown

Green

Yellow

Blue

Pink

-

Do not connect

Do not connect

8

9

3

6

5

4

1

2, 7, 11, 12, 13

14

10

15

Case

RGB25 interface 15 pin  

D type socket input

Inner shield (not UHV) 

Outer shield

RGB25 input

Connections

Содержание RCH24H30D30A

Страница 1: ...RGH24 25U series readhead Installation guide M 9541 0084 04 C...

Страница 2: ...r M 9517 2855 These can be downloaded from our website www renishaw com encoder and are also available from your local representative This document may not be copied or reproduced in whole or in part...

Страница 3: ...mark sensor limit switch sensor position Optical centreline A 9541 0037 Reference mark actuator 4 8 2 Mounting holes M3 x 0 5 through Set up LED 5 4 3 17 JST connector version 12 8 5 5 Arrow indicates...

Страница 4: ...ashes orange or goes blank the reference mark adjuster screw should be turned anti clockwise by 1 8 turn and the procedure repeated until a red flash is obtained RGH24 Red Orange Blank LED flash durin...

Страница 5: ...ued RGH25 RGB25 Red Orange Blank LED flash during reference mark traverse only turn 1 8 RGB25 input all models Function Power Incremental signals Reference mark Not connected Sin monitor Cos monitor S...

Страница 6: ...forced open circuit for 20 ms when signal too low for reliable operation For RGH24W Y H I O incremental channels forced open circuit for 10 ms when signal too low or speed too high for reliable operat...

Страница 7: ...dheads have been designed to the relevant EMC standards but must be correctly integrated to achieve EMC compliance In particular attention to shielding arrangements is critical Renishaw recommends the...

Страница 8: ...Check valid options online at www renishaw com epc Readhead part numbers A Options 00 Standard RGH24B C D X and Z only 01 JST connector RGH24D X and Z only 30 12 MHz customer clock RGH24H I O and Y o...

Страница 9: ...de contact details please visit our main website at www renishaw com contact RENISHAW and the probe emblem used in the RENISHAW logo are registered trademarks of Renishaw plc in the UK and other count...

Отзывы: