4
QUANTiC RKLC40-S linear installation guide
RKLC40-S scale installation drawing
*
Dimension from substrate
†
Supplied with 2 × M2 × 4 screws.
NOTES:
The reference mark selector and limit actuator locations are correct for the readhead orientation shown.
External magnetic fields greater than 6 mT, in the vicinity of the readhead, may cause false activation of the limit and reference sensors.
Scale length (L)
Measuring length ML = (L − 40) (ML = (L − 55) with dual limits)
0.5
F
0.2 /100
20
A
P limit magnet
(A-9653-0138)
(Dimensions as Q limit
)
RKLC40-S scale
Reference mark selector magnet
(A-9653-0143)
(Dimensions as Q limit)
35
Q limit magnet
(A-9653-0139)
6
Readhead optical detector position at extent of travel
Ra 3.2
0.05
F
F = axis of motion
F = axis of motion
IN-TRAC
reference mark
Overall length (L + 30)
15 ±1
3.7
9.7
13
30
10
15
End clamp
(Pair A-9523-4015)
QUANTiC readhead
P and Q limit switch
sensor position
Optical centreline
(Incremental and reference mark)
9.2
Nominal P limit trigger point
Nominal Q limit trigger point
Detail A
(20 when Q limit
not used)
1.5*
22
18
10
3.7
Ø2.2
†
1.85
18.5 ±1
Bolted magnet type
Part number
Reference mark selector
A-9653-0290
Q limit
A-9653-0291
P limit
A-9653-0292
Optional bolted reference mark selector and limit magnets
Dimensions and tolerances in mm