Product description
2. Audible indicator
The audible indicator has two functions:
1.
To provide a brief indication that a probe trigger has occurred. This function may
be disabled by configuration switch 5.
2.
To warn, by a continuous tone, that the stylus has remained deflected for longer
than 10 seconds. The alarm can be cleared by operation of the RESET button
on the front panel. Refer to the section ‘Reset button’ for more information on
resetting the probe.
2.0 Rear panel switches and connectors
Figure 7 -
PI 200 interface back panel
Содержание PI 200