background image

Removing the OMI-2 window

It is not necessary to remove the OMI-2 from 
the machine when adjusting the switches or 
installing new parts.

To remove the OMI-2 window:

 

CAUTION: DO NOT

 remove the window by 

twisting or rotating.

1.  Clean the OMI-2 to ensure that no debris 

enters the unit.

2.  Remove the four cover screws using the 

2.5 mm A/F hexagon key supplied with 
the kit. Two screws are short and two are 
long. Two of the cover holes are threaded 

and two are plain 

B

.

3.  The window fits tightly in the OMI-2 body 

and is removed using the two long screws 
which are inserted into the threaded 
holes 

A

.

 

Tighten each screw a few turns at a time 
to lift the window evenly. When it is clear 
of the body, remove the window and 
screws completely.

4.  Discard the used window and O-ring.

Window

A

A

Fitting the OMI-2 window

1.  Before fitting the window, check for any 

damage to screws or scratch marks which 
could prevent sealing.

2.  Ensure that the O-ring seating 

C

 in the 

OMI-2 body is clean, and there are no 
scratch marks which could prevent complete 
sealing. 

3.  Ensure that the O-ring 

D

 and window 

E

 are 

clean.

4.   Insert the two short screws into window 

holes 

A

 and tighten. 

5.  Place the window, complete with O-ring, 

onto the OMI-2 body.

NOTE: 

The O-ring should be lubricated with 

silicone grease to prevent nicking.

6.  Insert the long screws into holes 

B

. Tighten 

each screw, a few turns at a time, to pull the 
window down evenly. There may be some 
resistance due to compression of air trapped 
inside the body.

C

E

D

A

B

A

B

A

B

B

A

2.5 mm A/F 

× 4

M3 screws (

A

2.5 mm A/F × 2 
0.3 to 0.5 Nm 
(0.22 to 0.37 lbf.ft)

M3 screws (

B

2.5 mm A/F × 2 
0.9 to 1.1 Nm 
(0.66 to 0.81 lbf.ft)