1-2
The interface unit may be mounted
inside the CNC machine cabinet,
using the optional panel mounting
kit.
Holes must be cut in the
machine protective panel to
accept the MI 12 front panel
and fixing screws as shown
in diagram.
A.
Four countersunk holes
Ø8,5 to Ø5 mm (Ø0.33 to Ø0.19 in)
B.
Six holes
Ø4 mm (Ø0.16 in) through.
Counterbore Ø7 x 1 mm
(Ø0.27 x 0.04 in) deep.
PANEL CUT OUT
B
B
B
B
B
B
A
A
A
A
Ø8,5 (0.33)
Ø5 (0.19)
2,64 (12 SWG)
45°
Ø4 (0.16)
Ø7 (0.27)
1 (0.04)
69 (2.7)
30 (1.18)
56 (2.20)
1
3 (0.52)
6,5
(02.5)
135 (5.31)
76 (2.99)
152 (5.98)
A
Ø8,5 (0.33)
Dimensions mm (in)
MI 12 INTERFACE UNIT
PANEL MOUNTING KIT
Part no. A-2033-0690
B